---
title: "South Harrison Water Corporation (IN5231006) Water Quality"
url: https://gcsradheat.com/water-quality/indiana/in5231006-south-harrison-water-corporation/
description: "Ranked #101 of 210 major community water utilities in Indiana, South Harrison Water Corporation (IN5231006) delivers ground water to 9,057 people around."
---

EPA SDWA profile · IN5231006 (Indiana)

# South Harrison Water Corporation Water Quality, PFAS & Utility Report (IN5231006)

Ranked #101 of 210 major community water utilities in Indiana, South Harrison Water Corporation (IN5231006) delivers ground water to 9,057 people around Corydon. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that all 60 federal UCMR 5 PFAS lab runs tested non-detect. Recommended home check: Standard sediment pre-filter + NSF 53 lead check.

- **EPA PWSID** : IN5231006

- **Population Served** : 9,057

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for IN5231006

Because South Harrison Water Corporation relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Indiana's statewide USGS median is 6.8 GPG (Moderately Hard). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 11,766 housing units in South Harrison Water Corporation's 7 ZIP codes (median value $198,017), 41.9% predates 1980 (23.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define IN5231006?

These verified utility measurements pair EPA SDWIS facility data for South Harrison Water Corporation with Census housing vintage across its 7 served ZIP codes.

EPA SDWA and local housing profile for South Harrison Water Corporation (IN5231006)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | IN5231006 (Local Government) | Active CWS | Last sanitary visit: 10/08/2024 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 9,057 residents | #101 in Indiana | Counties: Harrison |
| Served ZIP Codes | 47110, 47112, 47117, 47132, 47135, 47136, 47160 | 7 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 41.9% (23.5% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 6.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do South Harrison Water Corporation PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect South Harrison Water Corporation's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IN5231006

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in Indiana?

Cross-check four peer Indiana water utilities to see how South Harrison Water Corporation ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Indiana for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Tell City Water Department](https://gcsradheat.com/water-quality/indiana/in5262004-tell-city-water-department/) (IN5262004) | Tell City | 9,315 | Groundwater | 0 |
| [Dubois Water Utilities](https://gcsradheat.com/water-quality/indiana/in5219002-dubois-water-utilities/) (IN5219002) | Dubois | 9,078 | Surface / Mixed | 0 |
| [Southern Monroe Water Authority](https://gcsradheat.com/water-quality/indiana/in5253007-southern-monroe-water-authority/) (IN5253007) | Bloomington | 8,877 | Surface / Mixed | 0 |
| [Morgan County Rural Water Company](https://gcsradheat.com/water-quality/indiana/in5255010-morgan-county-rural-water-company/) (IN5255010) | Martinsville | 8,800 | Groundwater | 0 |

## When Should South Harrison Water Corporation Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Corydon; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (6.8 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From South Harrison Water Corporation

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 9,057 customers under EPA ID IN5231006?

EPA ECHO classifies South Harrison Water Corporation (IN5231006) as a Ground Water community system serving 9,057 residents across Harrison. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### How do South Harrison Water Corporation PFAS levels compare to EPA's 4.0 ppt federal limit?

Federal UCMR 5 sampling covering 60 laboratory tests for South Harrison Water Corporation reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### What pipe materials should homeowners served by South Harrison Water Corporation inspect?

Across the 6 ZIP codes served by South Harrison Water Corporation, approximately 41.9% of residential housing units were built before 1980 (23.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for IN

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Tell City Water Department (IN5262004)→](https://gcsradheat.com/water-quality/indiana/in5262004-tell-city-water-department/)
- [Compare Dubois Water Utilities (IN5219002)→](https://gcsradheat.com/water-quality/indiana/in5219002-dubois-water-utilities/)
- [Browse All Indiana Community Water Utilities→](https://gcsradheat.com/water-quality/indiana/)
- [Inspect Indiana County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/indiana/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (IN)

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

Serving Corydon via groundwater; confirm cartridge micron & NSF 53/58 certifications locally.
[All Indiana Utilities](https://gcsradheat.com/water-quality/indiana/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
