---
title: "Portland Municipal Water Plant (IN5238007) Water Quality"
url: https://gcsradheat.com/water-quality/indiana/in5238007-portland-municipal-water-plant/
description: "Homeowners connected to Portland Municipal Water Plant (IN5238007) in Portland, Indiana receive ground water across a 6,209-person distribution network. EPA."
---

Community water audit · IN5238007 in IN

# Portland Municipal Water Plant Water Quality, PFAS & Utility Report (IN5238007)

Homeowners connected to Portland Municipal Water Plant (IN5238007) in Portland, Indiana receive ground water across a 6,209-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, all 60 federal UCMR 5 PFAS lab runs tested non-detect, and 73.7% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : IN5238007

- **Population Served** : 6,209

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Portland Municipal Water Plant

Because Portland Municipal Water Plant relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Indiana's statewide USGS median is 6.8 GPG (Moderately Hard). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 5,458 housing units in Portland Municipal Water Plant's 1 ZIP code (median value $116,100), 73.7% predates 1980 (50.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Portland Municipal Water Plant?

Examine Portland Municipal Water Plant's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Jay.

EPA SDWA and local housing profile for Portland Municipal Water Plant (IN5238007)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | IN5238007 (Local Government) | Active CWS | Last sanitary visit: 07/25/2023 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 6,209 residents | #139 in Indiana | Counties: Jay |
| Served ZIP Codes | 47371 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 73.7% (50.5% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 6.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Portland Municipal Water Plant Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify IN5238007's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IN5238007

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest Indiana Community System Peers?

Compare four other Indiana utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Indiana for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Garrett Water Utility](https://gcsradheat.com/water-quality/indiana/in5217004-garrett-water-utility/) (IN5217004) | Garrett | 6,390 | Groundwater | 0 |
| [Rochester Water Department](https://gcsradheat.com/water-quality/indiana/in5225006-rochester-water-department/) (IN5225006) | Rochester | 6,218 | Groundwater | 0 |
| [Yorktown Water Department](https://gcsradheat.com/water-quality/indiana/in5218014-yorktown-water-department/) (IN5218014) | Yorktown | 6,200 | Groundwater | 0 |
| [Rensselaer Water Department](https://gcsradheat.com/water-quality/indiana/in5237005-rensselaer-water-department/) (IN5237005) | Rensselaer | 6,200 | Groundwater | 0 |

## When Should Portland Municipal Water Plant Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Portland; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (6.8 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: IN5238007

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Portland Municipal Water Plant's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Portland Municipal Water Plant (IN5238007) as a Ground Water community system serving 6,209 residents across Jay. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Portland Municipal Water Plant homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 60 laboratory tests for Portland Municipal Water Plant reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Portland Municipal Water Plant?

Across the 1 ZIP codes served by Portland Municipal Water Plant, approximately 73.7% of residential housing units were built before 1980 (50.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Indiana

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Garrett Water Utility (IN5217004)→](https://gcsradheat.com/water-quality/indiana/in5217004-garrett-water-utility/)
- [Compare Rochester Water Department (IN5225006)→](https://gcsradheat.com/water-quality/indiana/in5225006-rochester-water-department/)
- [Browse All Indiana Community Water Utilities→](https://gcsradheat.com/water-quality/indiana/)
- [Inspect Indiana County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/indiana/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

EPA IN5238007 serves 6,209 people; match drinking tap filters and scale prevention to Portland water.
[All Indiana Utilities](https://gcsradheat.com/water-quality/indiana/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
