title: "Aberdeen Pate Water Company, Inc. (IN5258001) Water Quality"
url: https://gcsradheat.com/water-quality/indiana/in5258001-aberdeen-pate-water-company-inc/
description: "Homeowners connected to Aberdeen Pate Water Company, Inc. (IN5258001) in Aurora, Indiana receive ground water across a 4,787-person distribution network. EPA."
---

Community water audit · IN5258001 in IN

# Aberdeen Pate Water Company, Inc. Water Quality, PFAS & Utility Report (IN5258001)

Homeowners connected to Aberdeen Pate Water Company, Inc. (IN5258001) in Aurora, Indiana receive ground water across a 4,787-person distribution network. EPA SDWIS records document zero EPA health violations alongside 1 monitoring/reporting notice; under UCMR 5 monitoring, all 60 federal UCMR 5 PFAS lab runs tested non-detect, and 58.9% of homes across 8 served ZIP codes predate 1980.

- **EPA PWSID** : IN5258001

- **Population Served** : 4,787

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Aberdeen Pate Water Company, Inc.

Because Aberdeen Pate Water Company, Inc. relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Indiana's statewide USGS median is 6.8 GPG (Moderately Hard). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 11,792 housing units in Aberdeen Pate Water Company, Inc.'s 8 ZIP codes (median value $201,214), 58.9% predates 1980 (33.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Aberdeen Pate Water Company, Inc.?

Examine Aberdeen Pate Water Company, Inc.'s raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Ohio.

EPA SDWA and local housing profile for Aberdeen Pate Water Company, Inc. (IN5258001)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | IN5258001 (Private) | Active CWS | Last sanitary visit: 10/03/2023 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 4,787 residents | #166 in Indiana | Counties: Ohio |
| Served ZIP Codes | 47001, 47011, 47017, 47018, 47021, 47040, 47042, 47224 | 8 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 58.9% (33.9% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (5 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 6.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Aberdeen Pate Water Company, Inc. Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify IN5258001's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IN5258001

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| Lead / Copper 90th Pct | Pb: — / Cu: 2 | 10 ppb Lead (LCRI) / 1.3 ppm Cu | Utility distribution sample |

## Who Are the Closest Indiana Community System Peers?

Compare four other Indiana utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Indiana for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Whiting Water Department](https://gcsradheat.com/water-quality/indiana/in5245048-whiting-water-department/) (IN5245048) | Whiting | 4,900 | Surface / Mixed | 0 |
| [Gibson Water Authority](https://gcsradheat.com/water-quality/indiana/in5226009-gibson-water-authority/) (IN5226009) | Haubstadt | 4,835 | Surface / Mixed | 0 |
| [Clinton Water Utility](https://gcsradheat.com/water-quality/indiana/in5283004-clinton-water-utility/) (IN5283004) | Clinton | 4,773 | Groundwater | 0 |
| [B&B Water Project, Inc.](https://gcsradheat.com/water-quality/indiana/in5253001-b-b-water-project-inc/) (IN5253001) | Bloomington | 4,695 | Surface / Mixed | 0 |

## When Should Aberdeen Pate Water Company, Inc. Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Aurora; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (6.8 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: IN5258001

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Aberdeen Pate Water Company, Inc.'s supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Aberdeen Pate Water Company, Inc. (IN5258001) as a Ground Water community system serving 4,787 residents across Ohio. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Aberdeen Pate Water Company, Inc. homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 60 laboratory tests for Aberdeen Pate Water Company, Inc. reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Aberdeen Pate Water Company, Inc.?

Across the 7 ZIP codes served by Aberdeen Pate Water Company, Inc., approximately 58.9% of residential housing units were built before 1980 (33.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Indiana

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Whiting Water Department (IN5245048)→](https://gcsradheat.com/water-quality/indiana/in5245048-whiting-water-department/)
- [Compare Gibson Water Authority (IN5226009)→](https://gcsradheat.com/water-quality/indiana/in5226009-gibson-water-authority/)
- [Browse All Indiana Community Water Utilities→](https://gcsradheat.com/water-quality/indiana/)
- [Inspect Indiana County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/indiana/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

EPA IN5258001 serves 4,787 people; match drinking tap filters and scale prevention to Aurora water.
[All Indiana Utilities](https://gcsradheat.com/water-quality/indiana/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)