title: "Waverly Water Department (IA0990085) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/iowa/ia0990085-waverly-water-department/
description: "Homeowners connected to Waverly Water Department (IA0990085) in Waverly, Iowa receive ground water across a 10,394-person distribution network. EPA SDWIS."
---

Community water audit · IA0990085 in IA

# Waverly Water Department Water Quality, PFAS & Utility Report (IA0990085)

Homeowners connected to Waverly Water Department (IA0990085) in Waverly, Iowa receive ground water across a 10,394-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, UCMR 5 samples measured 15.0 ppt for PFHxS (exceeding the 4.0 ppt federal rule), and 58.5% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : IA0990085

- **Population Served** : 10,394

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 15.0 ppt (PFHxS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Waverly Water Department

Drawing surface water across Waverly, Waverly Water Department uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 15.0 ppt for PFHxS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 5,053 housing units in Waverly Water Department's 1 ZIP code (median value $221,600), 58.5% predates 1980 (29.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Waverly Water Department?

Examine Waverly Water Department's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Bremer.

EPA SDWA and local housing profile for Waverly Water Department (IA0990085)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | IA0990085 (Local Government) | Active CWS | Last sanitary visit: 02/03/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 10,394 residents | #50 in Iowa | Counties: Bremer |
| Served ZIP Codes | 50677 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 58.5% (29.1% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Waverly Water Department Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify IA0990085's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IA0990085

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 7.2 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | 15.0 ppt | 10 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest Iowa Community System Peers?

Compare four other Iowa utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Iowa for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Pella Water Works Department](https://gcsradheat.com/water-quality/iowa/ia6368033-pella-water-works-department/) (IA6368033) | Pella | 11,052 | Groundwater | 0 |
| [Lemars Water Department](https://gcsradheat.com/water-quality/iowa/ia7540174-lemars-water-department/) (IA7540174) | Le Mars | 10,606 | Groundwater | 0 |
| [Carroll Municipal Water Supply](https://gcsradheat.com/water-quality/iowa/ia1415072-carroll-municipal-water-supply/) (IA1415072) | Carroll | 10,321 | Groundwater | 0 |
| [Keokuk Municipal Water Works](https://gcsradheat.com/water-quality/iowa/ia5640019-keokuk-municipal-water-works/) (IA5640019) | Keokuk | 9,900 | Surface / Mixed | 0 |

## When Should Waverly Water Department Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Waverly; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: IA0990085

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Waverly Water Department's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Waverly Water Department (IA0990085) as a Ground Water community system serving 10,394 residents across Bremer. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Waverly Water Department homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for IA0990085 recorded 5 PFAS detections peaking at 15.0 ppt (PFHxS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Waverly Water Department?

Across the 1 ZIP codes served by Waverly Water Department, approximately 58.5% of residential housing units were built before 1980 (29.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Iowa

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Pella Water Works Department (IA6368033)→](https://gcsradheat.com/water-quality/iowa/ia6368033-pella-water-works-department/)
- [Compare Lemars Water Department (IA7540174)→](https://gcsradheat.com/water-quality/iowa/ia7540174-lemars-water-department/)
- [Browse All Iowa Community Water Utilities→](https://gcsradheat.com/water-quality/iowa/)
- [Inspect Iowa County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/iowa/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA IA0990085 serves 10,394 people; match drinking tap filters and scale prevention to Waverly water.
[All Iowa Utilities](https://gcsradheat.com/water-quality/iowa/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)