# Inima Usa / Aquaria Llc Water Quality, PFAS & Utility Report (MA4076004)

Inima Usa / Aquaria Llc (MA4076004) is a Private public water utility serving 105,643 residents in Dighton, Massachusetts primarily from surface water. EPA ECHO logs show zero EPA health violations alongside 1 monitoring/reporting notice, while all 120 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 81.8% of homes across 2 served ZIP codes predate 1980.

- **EPA PWSID** : MA4076004

- **Population Served** : 105,643

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Inima Usa / Aquaria Llc

Drawing surface water across Dighton, Inima Usa / Aquaria Llc uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 26,109 housing units in Inima Usa / Aquaria Llc's 2 ZIP codes (median value $456,150), 81.8% predates 1980 (55.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Inima Usa / Aquaria Llc's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Inima Usa / Aquaria Llc's network.

EPA SDWA and local housing profile for Inima Usa / Aquaria Llc (MA4076004)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | MA4076004 (Private) | Active CWS | Last sanitary visit: 08/12/2026 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 105,643 residents | #10 in Massachusetts | Counties: Bristol |
| Served ZIP Codes | 02301, 02764 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 81.8% (55.0% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | 2005=Endrin, 2010=Bhc-Gamma, 2015=Methoxychlor, 2020=Toxaphene |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did MA4076004 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Inima Usa / Aquaria Llc against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for MA4076004

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Inima Usa / Aquaria Llc Compare to Peer Massachusetts Utilities?

Review four nearby Massachusetts community water utilities matched by service rank inside Massachusetts's 262-utility public water catalog.

Nearby community water systems in Massachusetts for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Quincy Water Dept. (Mwra)](https://gcsradheat.com/water-quality/massachusetts/ma3243000-quincy-water-dept-mwra/) (MA3243000) | Quincy | 106,000 | Surface / Mixed | 0 |
| [Brockton Water Department](https://gcsradheat.com/water-quality/massachusetts/ma4044000-brockton-water-department/) (MA4044000) | Brockton | 105,788 | Surface / Mixed | 0 |
| [Lynn Water And Sewer Comm](https://gcsradheat.com/water-quality/massachusetts/ma3163000-lynn-water-and-sewer-comm/) (MA3163000) | Lynn | 101,253 | Surface / Mixed | 0 |
| [City Of New Bedford Dpi](https://gcsradheat.com/water-quality/massachusetts/ma4201000-city-of-new-bedford-dpi/) (MA4201000) | New Bedford | 101,079 | Surface / Mixed | 0 |

## When Should Inima Usa / Aquaria Llc Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Dighton; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Inima Usa / Aquaria Llc (MA4076004)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Inima Usa / Aquaria Llc (MA4076004) source drinking water?

EPA ECHO classifies Inima Usa / Aquaria Llc (MA4076004) as a Surface Water community system serving 105,643 residents across Bristol. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Inima Usa / Aquaria Llc UCMR 5 testing?

Federal UCMR 5 sampling covering 120 laboratory tests for Inima Usa / Aquaria Llc reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Could homes served by Inima Usa / Aquaria Llc still face lead solder or older pipe risks?

Across the 2 ZIP codes served by Inima Usa / Aquaria Llc, approximately 81.8% of residential housing units were built before 1980 (55.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Dighton

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Quincy Water Dept. (Mwra) (MA3243000)→](https://gcsradheat.com/water-quality/massachusetts/ma3243000-quincy-water-dept-mwra/)
- [Compare Brockton Water Department (MA4044000)→](https://gcsradheat.com/water-quality/massachusetts/ma4044000-brockton-water-department/)
- [Browse All Massachusetts Community Water Utilities→](https://gcsradheat.com/water-quality/massachusetts/)
- [Inspect Massachusetts County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/massachusetts/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for MA4076004

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Match filters to surface water chemistry in Dighton, MA. State hardness baseline: Check CCR GPG.
[All Massachusetts Utilities](https://gcsradheat.com/water-quality/massachusetts/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)