title: "Lincoln-Pipestone Rural Water System (MN1410007) Water Quality"
url: https://gcsradheat.com/water-quality/minnesota/mn1410007-lincoln-pipestone-rural-water-system/
description: "Lincoln-Pipestone Rural Water System (MN1410007) is a Local Government public water utility serving 13,644 residents in Lincoln, Minnesota primarily from."
---

Minnesota water passport · EPA MN1410007

# Lincoln-Pipestone Rural Water System Water Quality, PFAS & Utility Report (MN1410007)

Lincoln-Pipestone Rural Water System (MN1410007) is a Local Government public water utility serving 13,644 residents in Lincoln, Minnesota primarily from surface water purchased. EPA ECHO logs show zero EPA health violations alongside 1 monitoring/reporting notice, while all 300 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 76.6% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : MN1410007

- **Population Served** : 13,644

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Lincoln-Pipestone Rural Water System

Drawing surface water across Lincoln, Lincoln-Pipestone Rural Water System uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 734 housing units in Lincoln-Pipestone Rural Water System's 1 ZIP code (median value $150,800), 76.6% predates 1980 (41.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Lincoln-Pipestone Rural Water System's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Lincoln-Pipestone Rural Water System's network.

EPA SDWA and local housing profile for Lincoln-Pipestone Rural Water System (MN1410007)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | MN1410007 (Local Government) | Active CWS | Last sanitary visit: 06/18/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 13,644 residents | #81 in Minnesota | Counties: Lincoln |
| Served ZIP Codes | 56149 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 76.6% (41.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (2 qtrs) | Zero health flags target | 5000=Lead And Copper Rule |
| State Tap Hardness Baseline | 12.5 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Did MN1410007 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Lincoln-Pipestone Rural Water System against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for MN1410007

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Lincoln-Pipestone Rural Water System Compare to Peer Minnesota Utilities?

Review four nearby Minnesota community water utilities matched by service rank inside Minnesota's 189-utility public water catalog.

Nearby community water systems in Minnesota for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Marshall](https://gcsradheat.com/water-quality/minnesota/mn1420006-marshall/) (MN1420006) | Lyon | 13,890 | Groundwater | 0 |
| [Sauk Rapids](https://gcsradheat.com/water-quality/minnesota/mn1050004-sauk-rapids/) (MN1050004) | Benton | 13,835 | Groundwater | 0 |
| [Waconia](https://gcsradheat.com/water-quality/minnesota/mn1100010-waconia/) (MN1100010) | Carver | 13,277 | Groundwater | 0 |
| [Mounds View](https://gcsradheat.com/water-quality/minnesota/mn1620008-mounds-view/) (MN1620008) | Ramsey | 13,256 | Groundwater | 0 |

## When Should Lincoln-Pipestone Rural Water System Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Lincoln; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (12.5 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Lincoln-Pipestone Rural Water System (MN1410007)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Lincoln-Pipestone Rural Water System (MN1410007) source drinking water?

EPA ECHO classifies Lincoln-Pipestone Rural Water System (MN1410007) as a Surface Water Purchased community system serving 13,644 residents across Lincoln. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Lincoln-Pipestone Rural Water System UCMR 5 testing?

Federal UCMR 5 sampling covering 300 laboratory tests for Lincoln-Pipestone Rural Water System reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Could homes served by Lincoln-Pipestone Rural Water System still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Lincoln-Pipestone Rural Water System, approximately 76.6% of residential housing units were built before 1980 (41.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Lincoln

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Marshall (MN1420006)→](https://gcsradheat.com/water-quality/minnesota/mn1420006-marshall/)
- [Compare Sauk Rapids (MN1050004)→](https://gcsradheat.com/water-quality/minnesota/mn1050004-sauk-rapids/)
- [Browse All Minnesota Community Water Utilities→](https://gcsradheat.com/water-quality/minnesota/)
- [Inspect Minnesota County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/minnesota/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for MN1410007

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Match filters to surface water chemistry in Lincoln, MN. State hardness baseline: 12.5 GPG.
[All Minnesota Utilities](https://gcsradheat.com/water-quality/minnesota/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)