---
title: "Haddon Twp Water Departm (NJ0416001) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/new-jersey/nj0416001-haddon-twp-water-departm/
description: "Operating under Local Government management in Haddon Twp.-0416, New Jersey, Haddon Twp Water Departm (NJ0416001) serves 11,938 residents via surface water."
---

Safe drinking water record · NJ0416001

# Haddon Twp Water Departm Water Quality, PFAS & Utility Report (NJ0416001)

Operating under Local Government management in Haddon Twp.-0416, New Jersey, Haddon Twp Water Departm (NJ0416001) serves 11,938 residents via surface water purchased. Federal screening logs show zero EPA health violations alongside 3 monitoring/reporting notices, all 180 federal UCMR 5 PFAS lab runs tested non-detect, making kitchen nsf 53 catalytic carbon filter the primary home filtration takeaway.

- **EPA PWSID** : NJ0416001

- **Population Served** : 11,938

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Local water quality & plumbing fit

Drawing surface water across Haddon Twp.-0416, Haddon Twp Water Departm uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 22,267 housing units in Haddon Twp Water Departm's 3 ZIP codes (median value $400,500), 89.8% predates 1980 (71.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Should Haddon Twp.-0416 Homeowners Know About Haddon Twp Water Departm?

Key federal SDWIS metrics for NJ0416001 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Haddon Twp Water Departm (NJ0416001)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NJ0416001 (Local Government) | Active CWS | Last sanitary visit: 03/13/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 11,938 residents | #140 in New Jersey | Counties: Camden |
| Served ZIP Codes | 08033, 08107, 08108 | 3 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 89.8% (71.3% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 3 rule violations (7 qtrs) | Zero health flags target | 0200=Surface Water Treatment Rule, 2456=Total Haloacetic Acids (Haa5) |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Does UCMR 5 Testing Reveal About NJ0416001?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Haddon Twp Water Departm in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NJ0416001

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Where Can You Compare Haddon Twp Water Departm With Other New Jersey Systems?

Four peer New Jersey utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in New Jersey for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Point Pleasant Beach Water Department](https://gcsradheat.com/water-quality/new-jersey/nj1525001-point-pleasant-beach-water-department/) (NJ1525001) | Point P. Beach Boro-1525 | 12,000 | Surface / Mixed | 0 |
| [Manchester Utilities Authority](https://gcsradheat.com/water-quality/new-jersey/nj1603001-manchester-utilities-authority/) (NJ1603001) | Haledon Boro-1603 | 12,000 | Surface / Mixed | 0 |
| [Nj American Water - Roxbury](https://gcsradheat.com/water-quality/new-jersey/nj1436002-nj-american-water-roxbury/) (NJ1436002) | Roxbury Twp.-1436 | 11,793 | Groundwater | 0 |
| [Berkeley Twp Mua](https://gcsradheat.com/water-quality/new-jersey/nj1505004-berkeley-twp-mua/) (NJ1505004) | Berkeley Twp.-1505 | 11,792 | Groundwater | 0 |

## When Should Haddon Twp Water Departm Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Haddon Twp.-0416; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Common Questions for Haddon Twp Water Departm Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is tap water from Haddon Twp Water Departm surface-treated or well-sourced?

EPA ECHO classifies Haddon Twp Water Departm (NJ0416001) as a Surface Water Purchased community system serving 11,938 residents across Camden. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Did Haddon Twp Water Departm exceed EPA's 4.0 ppt PFOA or PFOS standard?

Federal UCMR 5 sampling covering 180 laboratory tests for Haddon Twp Water Departm reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Are pre-1980 copper solder or galvanized lines common in Haddon Twp Water Departm's ZIP codes?

Across the 3 ZIP codes served by Haddon Twp Water Departm, approximately 89.8% of residential housing units were built before 1980 (71.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Explore New Jersey Counties, Softeners & Water Heaters

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Point Pleasant Beach Water Department (NJ1525001)→](https://gcsradheat.com/water-quality/new-jersey/nj1525001-point-pleasant-beach-water-department/)
- [Compare Manchester Utilities Authority (NJ1603001)→](https://gcsradheat.com/water-quality/new-jersey/nj1603001-manchester-utilities-authority/)
- [Browse All New Jersey Community Water Utilities→](https://gcsradheat.com/water-quality/new-jersey/)
- [Inspect New Jersey County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-jersey/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Tap Checklist (NJ0416001)

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Annual water heater flushing and kitchen nsf 53 catalytic carbon filter help protect fixtures across 3 Haddon Twp.-0416 ZIP codes.
[All New Jersey Utilities](https://gcsradheat.com/water-quality/new-jersey/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
