---
title: "Westville Water Department (NJ0821001) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/new-jersey/nj0821001-westville-water-department/
description: "Homeowners connected to Westville Water Department (NJ0821001) in Westville Boro-0821, New Jersey receive ground water across a 6,000-person distribution."
---

Community water audit · NJ0821001 in NJ

# Westville Water Department Water Quality, PFAS & Utility Report (NJ0821001)

Homeowners connected to Westville Water Department (NJ0821001) in Westville Boro-0821, New Jersey receive ground water across a 6,000-person distribution network. EPA SDWIS records document zero EPA health violations alongside 3 monitoring/reporting notices; under UCMR 5 monitoring, UCMR 5 samples measured 16.7 ppt for PFNA (exceeding the 4.0 ppt federal rule), and 80.9% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : NJ0821001

- **Population Served** : 6,000

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 16.7 ppt (PFNA)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Westville Water Department

Drawing surface water across Westville Boro-0821, Westville Water Department uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 16.7 ppt for PFNA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 4,473 housing units in Westville Water Department's 1 ZIP code (median value $192,800), 80.9% predates 1980 (44.2% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Westville Water Department?

Examine Westville Water Department's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Gloucester.

EPA SDWA and local housing profile for Westville Water Department (NJ0821001)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NJ0821001 (Local Government) | Active CWS | Last sanitary visit: 10/28/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 6,000 residents | #199 in New Jersey | Counties: Gloucester |
| Served ZIP Codes | 08093 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 80.9% (44.2% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 3 rule violations (4 qtrs) | Zero health flags target | 0999=Chlorine |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Westville Water Department Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify NJ0821001's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NJ0821001

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 8.6 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 4.7 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | 16.7 ppt | 10 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest New Jersey Community System Peers?

Compare four other New Jersey utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in New Jersey for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Awo&M - Picatinny Arsenal](https://gcsradheat.com/water-quality/new-jersey/nj1435003-awo-m-picatinny-arsenal/) (NJ1435003) | Rockaway Twp.-1435 | 6,011 | Groundwater | 0 |
| [North Caldwell Water Dep](https://gcsradheat.com/water-quality/new-jersey/nj0715001-north-caldwell-water-dep/) (NJ0715001) | North Caldwell Boro-0715 | 6,000 | Surface / Mixed | 0 |
| [Woodland Park Water Department](https://gcsradheat.com/water-quality/new-jersey/nj1616001-woodland-park-water-department/) (NJ1616001) | Woodland Park Boro-1616 | 6,000 | Surface / Mixed | 0 |
| [Nj American Water - Cape May Court House](https://gcsradheat.com/water-quality/new-jersey/nj0506010-nj-american-water-cape-may-court-house/) (NJ0506010) | Middle Twp.-0506 | 5,625 | Groundwater | 0 |

## When Should Westville Water Department Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Westville Boro-0821; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: NJ0821001

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Westville Water Department's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Westville Water Department (NJ0821001) as a Ground Water community system serving 6,000 residents across Gloucester. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Westville Water Department homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for NJ0821001 recorded 6 PFAS detections peaking at 16.7 ppt (PFNA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Westville Water Department?

Across the 1 ZIP codes served by Westville Water Department, approximately 80.9% of residential housing units were built before 1980 (44.2% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for New Jersey

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Awo&M - Picatinny Arsenal (NJ1435003)→](https://gcsradheat.com/water-quality/new-jersey/nj1435003-awo-m-picatinny-arsenal/)
- [Compare North Caldwell Water Dep (NJ0715001)→](https://gcsradheat.com/water-quality/new-jersey/nj0715001-north-caldwell-water-dep/)
- [Browse All New Jersey Community Water Utilities→](https://gcsradheat.com/water-quality/new-jersey/)
- [Inspect New Jersey County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-jersey/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA NJ0821001 serves 6,000 people; match drinking tap filters and scale prevention to Westville Boro-0821 water.
[All New Jersey Utilities](https://gcsradheat.com/water-quality/new-jersey/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
