---
title: "Spring Lake Water Department (NJ1348001) Water Quality"
url: https://gcsradheat.com/water-quality/new-jersey/nj1348001-spring-lake-water-department/
description: "Homeowners connected to Spring Lake Water Department (NJ1348001) in Spring Lake Boro-1348, New Jersey receive surface water purchased across a 11,270-person."
---

Community water audit · NJ1348001 in NJ

# Spring Lake Water Department Water Quality, PFAS & Utility Report (NJ1348001)

Homeowners connected to Spring Lake Water Department (NJ1348001) in Spring Lake Boro-1348, New Jersey receive surface water purchased across a 11,270-person distribution network. EPA SDWIS records document zero EPA health violations alongside 1 monitoring/reporting notice; under UCMR 5 monitoring, all 240 federal UCMR 5 PFAS lab runs tested non-detect, and 64.1% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : NJ1348001

- **Population Served** : 11,270

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Spring Lake Water Department

Drawing surface water across Spring Lake Boro-1348, Spring Lake Water Department uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 5,109 housing units in Spring Lake Water Department's 1 ZIP code (median value $871,400), 64.1% predates 1980 (31.4% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Spring Lake Water Department?

Examine Spring Lake Water Department's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Monmouth.

EPA SDWA and local housing profile for Spring Lake Water Department (NJ1348001)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NJ1348001 (Local Government) | Active CWS | Last sanitary visit: 06/24/2026 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 11,270 residents | #146 in New Jersey | Counties: Monmouth |
| Served ZIP Codes | 07762 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 64.1% (31.4% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (7 qtrs) | Zero health flags target | 5000=Lead And Copper Rule |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Spring Lake Water Department Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify NJ1348001's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NJ1348001

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest New Jersey Community System Peers?

Compare four other New Jersey utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in New Jersey for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Pompton Lakes Mua](https://gcsradheat.com/water-quality/new-jersey/nj1609001-pompton-lakes-mua/) (NJ1609001) | Pompton Lakes Boro-1609 | 11,435 | Groundwater | 0 |
| [East Hanover Twp Water Dept](https://gcsradheat.com/water-quality/new-jersey/nj1410001-east-hanover-twp-water-dept/) (NJ1410001) | East Hanover Twp.-1410 | 11,393 | Surface / Mixed | 0 |
| [Nj American Water - Little Falls](https://gcsradheat.com/water-quality/new-jersey/nj1605001-nj-american-water-little-falls/) (NJ1605001) | Little Falls Twp.-1605 | 11,247 | Surface / Mixed | 0 |
| [Florence Twp W Dept](https://gcsradheat.com/water-quality/new-jersey/nj0315001-florence-twp-w-dept/) (NJ0315001) | Florence Twp.-0315 | 11,214 | Groundwater | 0 |

## When Should Spring Lake Water Department Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Spring Lake Boro-1348; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: NJ1348001

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Spring Lake Water Department's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Spring Lake Water Department (NJ1348001) as a Surface Water Purchased community system serving 11,270 residents across Monmouth. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Spring Lake Water Department homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 240 laboratory tests for Spring Lake Water Department reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Spring Lake Water Department?

Across the 1 ZIP codes served by Spring Lake Water Department, approximately 64.1% of residential housing units were built before 1980 (31.4% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for New Jersey

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Pompton Lakes Mua (NJ1609001)→](https://gcsradheat.com/water-quality/new-jersey/nj1609001-pompton-lakes-mua/)
- [Compare East Hanover Twp Water Dept (NJ1410001)→](https://gcsradheat.com/water-quality/new-jersey/nj1410001-east-hanover-twp-water-dept/)
- [Browse All New Jersey Community Water Utilities→](https://gcsradheat.com/water-quality/new-jersey/)
- [Inspect New Jersey County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-jersey/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

EPA NJ1348001 serves 11,270 people; match drinking tap filters and scale prevention to Spring Lake Boro-1348 water.
[All New Jersey Utilities](https://gcsradheat.com/water-quality/new-jersey/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
