---
title: "Mountain Lakes Water Dep (NJ1425001) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/new-jersey/nj1425001-mountain-lakes-water-dep/
description: "Supplying 4,012 customers across Morris, New Jersey, Mountain Lakes Water Dep (EPA ID NJ1425001) relies on ground water for daily municipal flow. Current."
---

Utility quality file · Boonton Twp.-1402, Denville Twp.-1408, Mountain Lakes Boro-1425, Parsippany Troy-Hills-1429, NJ (NJ1425001)

# Mountain Lakes Water Dep Water Quality, PFAS & Utility Report (NJ1425001)

Supplying 4,012 customers across Morris, New Jersey, Mountain Lakes Water Dep (EPA ID NJ1425001) relies on ground water for daily municipal flow. Current federal compliance files record zero EPA health violations alongside 4 monitoring/reporting notices; meanwhile UCMR 5 samples measured 13.3 ppt for PFOA (exceeding the 4.0 ppt federal rule), and 73.4% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : NJ1425001

- **Population Served** : 4,012

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 13.3 ppt (PFOA)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — NJ1425001

Drawing surface water across Boonton Twp.-1402, Denville Twp.-1408, Mountain Lakes Boro-1425, Parsippany Troy-Hills-1429, Mountain Lakes Water Dep uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 13.3 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 1,451 housing units in Mountain Lakes Water Dep's 1 ZIP code (median value $915,100), 73.4% predates 1980 (62.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Is Mountain Lakes Water Dep's Municipal Water Supplied and Regulated?

Review Mountain Lakes Water Dep's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Mountain Lakes Water Dep (NJ1425001)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NJ1425001 (Local Government) | Active CWS | Last sanitary visit: 08/13/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 4,012 residents | #230 in New Jersey | Counties: Morris |
| Served ZIP Codes | 07046 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 73.4% (62.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 4 rule violations (12 qtrs) | Zero health flags target | 0999=Chlorine, 1040=Nitrate, 7000=Consumer Confidence Rule |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Do Federal PFAS Lab Results Show for Mountain Lakes Water Dep?

See how Mountain Lakes Water Dep (NJ1425001) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NJ1425001

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 13.3 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby New Jersey Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in New Jersey.

Nearby community water systems in New Jersey for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Riverdale Boro Water Dep](https://gcsradheat.com/water-quality/new-jersey/nj1433001-riverdale-boro-water-dep/) (NJ1433001) | Riverdale Boro-1433 | 4,103 | Surface / Mixed | 0 |
| [Ho Ho Kus Water Dept](https://gcsradheat.com/water-quality/new-jersey/nj0228001-ho-ho-kus-water-dept/) (NJ0228001) | Hohokus Boro-0228 | 4,060 | Groundwater | 0 |
| [Cape May Point Boro Wate](https://gcsradheat.com/water-quality/new-jersey/nj0503001-cape-may-point-boro-wate/) (NJ0503001) | Cape May Point Boro-0503 | 4,000 | Groundwater | 0 |
| [Veolia Water New Jersey Lambertville](https://gcsradheat.com/water-quality/new-jersey/nj1017001-veolia-water-new-jersey-lambertville/) (NJ1017001) | Lambertville City-1017 | 3,960 | Surface / Mixed | 0 |

## When Should Mountain Lakes Water Dep Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Boonton Twp.-1402, Denville Twp.-1408, Mountain Lakes Boro-1425, Parsippany Troy-Hills-1429; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for Boonton Twp.-1402, Denville Twp.-1408, Mountain Lakes Boro-1425, Parsippany Troy-Hills-1429 Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Mountain Lakes Water Dep draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Mountain Lakes Water Dep (NJ1425001) as a Ground Water community system serving 4,012 residents across Morris. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### What did federal UCMR 5 sampling measure in NJ1425001?

Yes—UCMR 5 laboratory testing for NJ1425001 recorded 7 PFAS detections peaking at 13.3 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside NJ1425001's service area?

Across the 1 ZIP codes served by Mountain Lakes Water Dep, approximately 73.4% of residential housing units were built before 1980 (62.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related New Jersey Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Riverdale Boro Water Dep (NJ1433001)→](https://gcsradheat.com/water-quality/new-jersey/nj1433001-riverdale-boro-water-dep/)
- [Compare Ho Ho Kus Water Dept (NJ0228001)→](https://gcsradheat.com/water-quality/new-jersey/nj0228001-ho-ho-kus-water-dept/)
- [Browse All New Jersey Community Water Utilities→](https://gcsradheat.com/water-quality/new-jersey/)
- [Inspect New Jersey County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-jersey/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Boonton Twp.-1402, Denville Twp.-1408, Mountain Lakes Boro-1425, Parsippany Troy-Hills-1429 Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 4,012 customers on groundwater, focus on install nsf 58 under-sink ro or nsf 53 pfas carbon before upgrading heaters.
[All New Jersey Utilities](https://gcsradheat.com/water-quality/new-jersey/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
