title: "Alfred State College (NY0220581) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/new-york/ny0220581-alfred-state-college/
description: "Alfred State College (NY0220581) is a State Or Territorial Government public water utility serving 3,600 residents in Alfred (V), New York primarily from."
---

New York water passport · EPA NY0220581

# Alfred State College Water Quality, PFAS & Utility Report (NY0220581)

Alfred State College (NY0220581) is a State Or Territorial Government public water utility serving 3,600 residents in Alfred (V), New York primarily from ground water purchased. EPA ECHO logs show zero EPA health violations alongside 4 monitoring/reporting notices, while all 60 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 85.9% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : NY0220581

- **Population Served** : 3,600

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Alfred State College

Because Alfred State College relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; New York's statewide USGS median is 1.4 GPG (Soft). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 675 housing units in Alfred State College's 1 ZIP code (median value $169,100), 85.9% predates 1980 (44.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Alfred State College's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Alfred State College's network.

EPA SDWA and local housing profile for Alfred State College (NY0220581)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NY0220581 (State Or Territorial Government) | Active CWS | Last sanitary visit: 10/01/2024 |
| Primary Source Water | Ground Water Purchased | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 3,600 residents | #289 in New York | Counties: Allegany |
| Served ZIP Codes | 14802 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 85.9% (44.0% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 4 rule violations (10 qtrs) | Zero health flags target | 2456=Total Haloacetic Acids (Haa5), 2950=Tthm |
| State Tap Hardness Baseline | 1.4 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did NY0220581 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Alfred State College against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NY0220581

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| Lead / Copper 90th Pct | Pb: 2 / Cu: 1 | 10 ppb Lead (LCRI) / 1.3 ppm Cu | Utility distribution sample |

## How Does Alfred State College Compare to Peer New York Utilities?

Review four nearby New York community water utilities matched by service rank inside New York's 308-utility public water catalog.

Nearby community water systems in New York for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Ticonderoga Wd](https://gcsradheat.com/water-quality/new-york/ny1500293-ticonderoga-wd/) (NY1500293) | Ticonderoga (T) | 3,700 | Surface / Mixed | 1 |
| [Perry Village](https://gcsradheat.com/water-quality/new-york/ny6000613-perry-village/) (NY6000613) | Castile (T), Perry (T), Perry (V) | 3,673 | Surface / Mixed | 0 |
| [Carthage Village](https://gcsradheat.com/water-quality/new-york/ny2202334-carthage-village/) (NY2202334) | Carthage (V) | 3,600 | Surface / Mixed | 0 |
| [Warrensburg Water District](https://gcsradheat.com/water-quality/new-york/ny5600112-warrensburg-water-district/) (NY5600112) | Warrensburg (T) | 3,600 | Groundwater | 0 |

## When Should Alfred State College Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Alfred (V); interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (1.4 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Alfred State College (NY0220581)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Alfred State College (NY0220581) source drinking water?

EPA ECHO classifies Alfred State College (NY0220581) as a Ground Water Purchased community system serving 3,600 residents across Allegany. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Were PFAS compounds detected in Alfred State College UCMR 5 testing?

Federal UCMR 5 sampling covering 60 laboratory tests for Alfred State College reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Could homes served by Alfred State College still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Alfred State College, approximately 85.9% of residential housing units were built before 1980 (44.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Alfred (V)

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ticonderoga Wd (NY1500293)→](https://gcsradheat.com/water-quality/new-york/ny1500293-ticonderoga-wd/)
- [Compare Perry Village (NY6000613)→](https://gcsradheat.com/water-quality/new-york/ny6000613-perry-village/)
- [Browse All New York Community Water Utilities→](https://gcsradheat.com/water-quality/new-york/)
- [Inspect New York County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-york/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for NY0220581

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

Match filters to groundwater chemistry in Alfred (V), NY. State hardness baseline: 1.4 GPG.
[All New York Utilities](https://gcsradheat.com/water-quality/new-york/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)