title: "Leray Town Wd 1, 2, 4 (NY2221206) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/new-york/ny2221206-leray-town-wd-1-2-4/
description: "Homeowners connected to Leray Town Wd 1, 2, 4 (NY2221206) in Leray (T), New York receive ground water across a 7,140-person distribution network. EPA SDWIS."
---

Community water audit · NY2221206 in NY

# Leray Town Wd 1, 2, 4 Water Quality, PFAS & Utility Report (NY2221206)

Homeowners connected to Leray Town Wd 1, 2, 4 (NY2221206) in Leray (T), New York receive ground water across a 7,140-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, UCMR 5 samples measured 14.0 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 69.9% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : NY2221206

- **Population Served** : 7,140

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 14.0 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Leray Town Wd 1, 2, 4

Because Leray Town Wd 1, 2, 4 relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; New York's statewide USGS median is 1.4 GPG (Soft). UCMR 5 samples reached 14.0 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 18,653 housing units in Leray Town Wd 1, 2, 4's 1 ZIP code (median value $170,100), 69.9% predates 1980 (55.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Leray Town Wd 1, 2, 4?

Examine Leray Town Wd 1, 2, 4's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Jefferson.

EPA SDWA and local housing profile for Leray Town Wd 1, 2, 4 (NY2221206)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NY2221206 (Local Government) | Active CWS | Last sanitary visit: 06/27/2023 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 7,140 residents | #201 in New York | Counties: Jefferson |
| Served ZIP Codes | 13601 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 69.9% (55.3% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 1.4 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Leray Town Wd 1, 2, 4 Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify NY2221206's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NY2221206

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest New York Community System Peers?

Compare four other New York utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in New York for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Williston Park (V)](https://gcsradheat.com/water-quality/new-york/ny2902858-williston-park-v/) (NY2902858) | Williston Park (V) | 7,287 | Groundwater | 0 |
| [Ecwa Boston](https://gcsradheat.com/water-quality/new-york/ny1421897-ecwa-boston/) (NY1421897) | Boston (T) | 7,250 | Surface / Mixed | 0 |
| [Canton Village](https://gcsradheat.com/water-quality/new-york/ny4404381-canton-village/) (NY4404381) | Canton (V) | 7,055 | Groundwater | 0 |
| [Brunswick Consolidated Water District](https://gcsradheat.com/water-quality/new-york/ny4110144-brunswick-consolidated-water-district/) (NY4110144) | Brunswick (T) | 7,050 | Surface / Mixed | 0 |

## When Should Leray Town Wd 1, 2, 4 Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Leray (T); interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (1.4 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: NY2221206

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Leray Town Wd 1, 2, 4's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Leray Town Wd 1, 2, 4 (NY2221206) as a Ground Water community system serving 7,140 residents across Jefferson. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Leray Town Wd 1, 2, 4 homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for NY2221206 recorded 2 PFAS detections peaking at 14.0 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Leray Town Wd 1, 2, 4?

Across the 1 ZIP codes served by Leray Town Wd 1, 2, 4, approximately 69.9% of residential housing units were built before 1980 (55.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for New York

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Williston Park (V) (NY2902858)→](https://gcsradheat.com/water-quality/new-york/ny2902858-williston-park-v/)
- [Compare Ecwa Boston (NY1421897)→](https://gcsradheat.com/water-quality/new-york/ny1421897-ecwa-boston/)
- [Browse All New York Community Water Utilities→](https://gcsradheat.com/water-quality/new-york/)
- [Inspect New York County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-york/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA NY2221206 serves 7,140 people; match drinking tap filters and scale prevention to Leray (T) water.
[All New York Utilities](https://gcsradheat.com/water-quality/new-york/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)