title: "Ontario Town Benefit Area #1 (NY5801233) Water Quality"
url: https://gcsradheat.com/water-quality/new-york/ny5801233-ontario-town-benefit-area-1/
description: "Homeowners connected to Ontario Town Benefit Area #1 (NY5801233) in Ontario (T), New York receive surface water across a 10,136-person distribution network."
---

Community water audit · NY5801233 in NY

# Ontario Town Benefit Area #1 Water Quality, PFAS & Utility Report (NY5801233)

Homeowners connected to Ontario Town Benefit Area #1 (NY5801233) in Ontario (T), New York receive surface water across a 10,136-person distribution network. EPA SDWIS records document zero EPA health violations alongside 1 monitoring/reporting notice; under UCMR 5 monitoring, all 120 federal UCMR 5 PFAS lab runs tested non-detect, and 50.6% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : NY5801233

- **Population Served** : 10,136

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Ontario Town Benefit Area #1

Drawing surface water across Ontario (T), Ontario Town Benefit Area #1 uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 5,281 housing units in Ontario Town Benefit Area #1's 1 ZIP code (median value $222,200), 50.6% predates 1980 (25.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Ontario Town Benefit Area #1?

Examine Ontario Town Benefit Area #1's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Wayne.

EPA SDWA and local housing profile for Ontario Town Benefit Area #1 (NY5801233)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NY5801233 (Local Government) | Active CWS | Last sanitary visit: 06/26/2025 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 10,136 residents | #148 in New York | Counties: Wayne |
| Served ZIP Codes | 14519 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 50.6% (25.0% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | 2920=Carbon, Total |
| State Tap Hardness Baseline | 1.4 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Ontario Town Benefit Area #1 Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify NY5801233's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NY5801233

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest New York Community System Peers?

Compare four other New York utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in New York for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Elma Water District No. 1](https://gcsradheat.com/water-quality/new-york/ny1420549-elma-water-district-no-1/) (NY1420549) | Elma (T) | 10,287 | Surface / Mixed | 0 |
| [North Greenbush Consolidated District](https://gcsradheat.com/water-quality/new-york/ny4130243-north-greenbush-consolidated-district/) (NY4130243) | North Greenbush (T) | 10,226 | Surface / Mixed | 0 |
| [Ogdensburg City](https://gcsradheat.com/water-quality/new-york/ny4404394-ogdensburg-city/) (NY4404394) | Ogdensburg (C) | 10,064 | Surface / Mixed | 0 |
| [Burnt Hills-Ballston Lk Wd](https://gcsradheat.com/water-quality/new-york/ny4505658-burnt-hills-ballston-lk-wd/) (NY4505658) | Ballston (T) | 10,000 | Surface / Mixed | 0 |

## When Should Ontario Town Benefit Area #1 Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Ontario (T); interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (1.4 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: NY5801233

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Ontario Town Benefit Area #1's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Ontario Town Benefit Area #1 (NY5801233) as a Surface Water community system serving 10,136 residents across Wayne. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Ontario Town Benefit Area #1 homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 120 laboratory tests for Ontario Town Benefit Area #1 reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Ontario Town Benefit Area #1?

Across the 1 ZIP codes served by Ontario Town Benefit Area #1, approximately 50.6% of residential housing units were built before 1980 (25.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for New York

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Elma Water District No. 1 (NY1420549)→](https://gcsradheat.com/water-quality/new-york/ny1420549-elma-water-district-no-1/)
- [Compare North Greenbush Consolidated District (NY4130243)→](https://gcsradheat.com/water-quality/new-york/ny4130243-north-greenbush-consolidated-district/)
- [Browse All New York Community Water Utilities→](https://gcsradheat.com/water-quality/new-york/)
- [Inspect New York County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/new-york/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

EPA NY5801233 serves 10,136 people; match drinking tap filters and scale prevention to Ontario (T) water.
[All New York Utilities](https://gcsradheat.com/water-quality/new-york/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)