title: "Murphy, Town Of (NC0120010) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/north-carolina/nc0120010-murphy-town-of/
description: "Ranked #244 of 290 major community water utilities in North Carolina, Murphy, Town Of (NC0120010) delivers surface water to 4,498 people around Murphy. Public."
---

EPA SDWA profile · NC0120010 (North Carolina)

# Murphy, Town Of Water Quality, PFAS & Utility Report (NC0120010)

Ranked #244 of 290 major community water utilities in North Carolina, Murphy, Town Of (NC0120010) delivers surface water to 4,498 people around Murphy. Public records indicate zero EPA health violations alongside 3 monitoring/reporting notices and note that all 120 federal UCMR 5 PFAS lab runs tested non-detect. Recommended home check: Kitchen NSF 53 catalytic carbon filter.

- **EPA PWSID** : NC0120010

- **Population Served** : 4,498

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for NC0120010

Drawing surface water across Murphy, Murphy, Town Of uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 12,992 housing units in Murphy, Town Of's 1 ZIP code (median value $219,800), 21.7% predates 1980 (7.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define NC0120010?

These verified utility measurements pair EPA SDWIS facility data for Murphy, Town Of with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Murphy, Town Of (NC0120010)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NC0120010 (Local Government) | Active CWS | Last sanitary visit: 01/22/2026 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 4,498 residents | #244 in North Carolina | Counties: Cherokee |
| Served ZIP Codes | 28906 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 21.7% (7.6% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 3 rule violations (6 qtrs) | Zero health flags target | 0999=Chlorine, 8000=Revised Total Coliform Rule |
| State Tap Hardness Baseline | 1.7 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Murphy, Town Of PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Murphy, Town Of's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NC0120010

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in North Carolina?

Cross-check four peer North Carolina water utilities to see how Murphy, Town Of ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in North Carolina for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Pfeiffer-N Stanly Water Assoc](https://gcsradheat.com/water-quality/north-carolina/nc0184025-pfeiffer-n-stanly-water-assoc/) (NC0184025) | Richfield | 4,513 | Surface / Mixed | 0 |
| [Ranlo, Town Of](https://gcsradheat.com/water-quality/north-carolina/nc0136034-ranlo-town-of/) (NC0136034) | Ranlo | 4,511 | Surface / Mixed | 0 |
| [Beaufort, Town Of](https://gcsradheat.com/water-quality/north-carolina/nc0416010-beaufort-town-of/) (NC0416010) | Beaufort | 4,452 | Groundwater | 0 |
| [Red Springs, Town Of](https://gcsradheat.com/water-quality/north-carolina/nc0378015-red-springs-town-of/) (NC0378015) | Red Springs | 4,423 | Groundwater | 0 |

## When Should Murphy, Town Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Murphy; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (1.7 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Murphy, Town Of

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 4,498 customers under EPA ID NC0120010?

EPA ECHO classifies Murphy, Town Of (NC0120010) as a Surface Water community system serving 4,498 residents across Cherokee. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Murphy, Town Of PFAS levels compare to EPA's 4.0 ppt federal limit?

Federal UCMR 5 sampling covering 120 laboratory tests for Murphy, Town Of reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### What pipe materials should homeowners served by Murphy, Town Of inspect?

Across the 1 ZIP codes served by Murphy, Town Of, approximately 21.7% of residential housing units were built before 1980 (7.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for NC

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Pfeiffer-N Stanly Water Assoc (NC0184025)→](https://gcsradheat.com/water-quality/north-carolina/nc0184025-pfeiffer-n-stanly-water-assoc/)
- [Compare Ranlo, Town Of (NC0136034)→](https://gcsradheat.com/water-quality/north-carolina/nc0136034-ranlo-town-of/)
- [Browse All North Carolina Community Water Utilities→](https://gcsradheat.com/water-quality/north-carolina/)
- [Inspect North Carolina County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/north-carolina/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (NC)

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Serving Murphy via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All North Carolina Utilities](https://gcsradheat.com/water-quality/north-carolina/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)