title: "Lamplighter South-Danby (NC0160156) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/north-carolina/nc0160156-lamplighter-south-danby/
description: "Lamplighter South-Danby (NC0160156) is a Private public water utility serving 3,297 residents in Charlotte, North Carolina primarily from surface water."
---

North Carolina water passport · EPA NC0160156

# Lamplighter South-Danby Water Quality, PFAS & Utility Report (NC0160156)

Lamplighter South-Danby (NC0160156) is a Private public water utility serving 3,297 residents in Charlotte, North Carolina primarily from surface water purchased. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while UCMR 5 samples measured 8.9 ppt for PFBS (exceeding the 4.0 ppt federal rule). Roughly 5.5% of homes across 3 served ZIP codes predate 1980.

- **EPA PWSID** : NC0160156

- **Population Served** : 3,297

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 8.9 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Lamplighter South-Danby

Drawing surface water across Charlotte, Lamplighter South-Danby uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 8.9 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 50,555 housing units in Lamplighter South-Danby's 3 ZIP codes (median value $427,733), 5.5% predates 1980 (1.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Lamplighter South-Danby's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Lamplighter South-Danby's network.

EPA SDWA and local housing profile for Lamplighter South-Danby (NC0160156)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | NC0160156 (Private) | Active CWS | Last sanitary visit: 09/10/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 3,297 residents | #281 in North Carolina | Counties: Mecklenburg |
| Served ZIP Codes | 28134, 28277, 29707 | 3 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 5.5% (1.6% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 1.7 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did NC0160156 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Lamplighter South-Danby against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for NC0160156

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 5.4 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 4.5 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Lamplighter South-Danby Compare to Peer North Carolina Utilities?

Review four nearby North Carolina community water utilities matched by service rank inside North Carolina's 290-utility public water catalog.

Nearby community water systems in North Carolina for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Moravian Falls Water System](https://gcsradheat.com/water-quality/north-carolina/nc0197040-moravian-falls-water-system/) (NC0197040) | Moravian Falls | 3,455 | Surface / Mixed | 0 |
| [Drexel Town Of](https://gcsradheat.com/water-quality/north-carolina/nc0112045-drexel-town-of/) (NC0112045) | Drexel | 3,302 | Surface / Mixed | 0 |
| [Grifton, Town Of](https://gcsradheat.com/water-quality/north-carolina/nc0474035-grifton-town-of/) (NC0474035) | Grifton | 2,982 | Surface / Mixed | 0 |
| [Old Fort, Town Of](https://gcsradheat.com/water-quality/north-carolina/nc0156025-old-fort-town-of/) (NC0156025) | Old Fort | 1,700 | Groundwater | 0 |

## When Should Lamplighter South-Danby Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Charlotte; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (1.7 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Lamplighter South-Danby (NC0160156)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Lamplighter South-Danby (NC0160156) source drinking water?

EPA ECHO classifies Lamplighter South-Danby (NC0160156) as a Surface Water Purchased community system serving 3,297 residents across Mecklenburg. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Lamplighter South-Danby UCMR 5 testing?

Yes—UCMR 5 laboratory testing for NC0160156 recorded 12 PFAS detections peaking at 8.9 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Could homes served by Lamplighter South-Danby still face lead solder or older pipe risks?

Across the 3 ZIP codes served by Lamplighter South-Danby, approximately 5.5% of residential housing units were built before 1980 (1.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Charlotte

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Moravian Falls Water System (NC0197040)→](https://gcsradheat.com/water-quality/north-carolina/nc0197040-moravian-falls-water-system/)
- [Compare Drexel Town Of (NC0112045)→](https://gcsradheat.com/water-quality/north-carolina/nc0112045-drexel-town-of/)
- [Browse All North Carolina Community Water Utilities→](https://gcsradheat.com/water-quality/north-carolina/)
- [Inspect North Carolina County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/north-carolina/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for NC0160156

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Match filters to surface water chemistry in Charlotte, NC. State hardness baseline: 1.7 GPG.
[All North Carolina Utilities](https://gcsradheat.com/water-quality/north-carolina/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)