---
title: "Dayton Public Water System (OH5703512) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/ohio/oh5703512-dayton-public-water-system/
description: "Homeowners connected to Dayton Public Water System (OH5703512) in Montgomery, Ohio receive surface water across a 141,407-person distribution network. EPA."
---

Community water audit · OH5703512 in OH

# Dayton Public Water System Water Quality, PFAS & Utility Report (OH5703512)

Homeowners connected to Dayton Public Water System (OH5703512) in Montgomery, Ohio receive surface water across a 141,407-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, UCMR 5 samples measured 10.0 ppt for PFOS (exceeding the 4.0 ppt federal rule), and 78.5% of homes across 24 served ZIP codes predate 1980.

- **EPA PWSID** : OH5703512

- **Population Served** : 141,407

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 10.0 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Dayton Public Water System

Drawing surface water across Montgomery, Dayton Public Water System uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 10.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 178,018 housing units in Dayton Public Water System's 24 ZIP codes (median value $138,300), 78.5% predates 1980 (47.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Dayton Public Water System?

Examine Dayton Public Water System's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Montgomery.

EPA SDWA and local housing profile for Dayton Public Water System (OH5703512)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | OH5703512 (Local Government) | Active CWS | Last sanitary visit: 06/17/2024 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 141,407 residents | #8 in Ohio | Counties: Montgomery |
| Served ZIP Codes | 45315, 45322, 45377, 45402, 45403, 45404, 45405, 45406 (+16 more) | 24 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 78.5% (47.6% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 15.6 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |

## Are Forever Chemicals Detected in Dayton Public Water System Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify OH5703512's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for OH5703512

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 10.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 9.8 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| Lead / Copper 90th Pct | Pb: 1 / Cu: — | 10 ppb Lead (LCRI) / 1.3 ppm Cu | Utility distribution sample |

## Who Are the Closest Ohio Community System Peers?

Compare four other Ohio utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Ohio for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Montgomery County Water Services 1 Pws](https://gcsradheat.com/water-quality/ohio/oh5701315-montgomery-county-water-services-1-pws/) (OH5701315) | Montgomery | 150,207 | Surface / Mixed | 0 |
| [Del-Co Water Company, Inc.](https://gcsradheat.com/water-quality/ohio/oh2101412-del-co-water-company-inc/) (OH2101412) | Delaware | 150,000 | Surface / Mixed | 0 |
| [Clermont Public Water System](https://gcsradheat.com/water-quality/ohio/oh1302212-clermont-public-water-system/) (OH1302212) | Clermont | 133,059 | Surface / Mixed | 0 |
| [Youngstown City Pws](https://gcsradheat.com/water-quality/ohio/oh5002303-youngstown-city-pws/) (OH5002303) | Mahoning | 130,530 | Surface / Mixed | 0 |

## When Should Dayton Public Water System Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Montgomery; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (15.6 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: OH5703512

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Dayton Public Water System's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Dayton Public Water System (OH5703512) as a Surface Water community system serving 141,407 residents across Montgomery. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Dayton Public Water System homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for OH5703512 recorded 9 PFAS detections peaking at 10.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Dayton Public Water System?

Across the 22 ZIP codes served by Dayton Public Water System, approximately 78.5% of residential housing units were built before 1980 (47.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Ohio

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Montgomery County Water Services 1 Pws (OH5701315)→](https://gcsradheat.com/water-quality/ohio/oh5701315-montgomery-county-water-services-1-pws/)
- [Compare Del-Co Water Company, Inc. (OH2101412)→](https://gcsradheat.com/water-quality/ohio/oh2101412-del-co-water-company-inc/)
- [Browse All Ohio Community Water Utilities→](https://gcsradheat.com/water-quality/ohio/)
- [Inspect Ohio County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/ohio/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA OH5703512 serves 141,407 people; match drinking tap filters and scale prevention to Montgomery water.
[All Ohio Utilities](https://gcsradheat.com/water-quality/ohio/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
