---
title: "Seminole (OK2006720) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/oklahoma/ok2006720-seminole/
description: "Operating under Local Government management in Seminole, Oklahoma, Seminole (OK2006720) serves 6,899 residents via ground water. Federal screening logs show."
---

Safe drinking water record · OK2006720

# Seminole Water Quality, PFAS & Utility Report (OK2006720)

Operating under Local Government management in Seminole, Oklahoma, Seminole (OK2006720) serves 6,899 residents via ground water. Federal screening logs show zero EPA health violations alongside 1 monitoring/reporting notice, all 1,020 federal UCMR 5 PFAS lab runs tested non-detect, making standard sediment pre-filter + nsf 53 lead check the primary home filtration takeaway.

- **EPA PWSID** : OK2006720

- **Population Served** : 6,899

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Local water quality & plumbing fit

Drawing surface water across Seminole, Seminole uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 5,361 housing units in Seminole's 2 ZIP codes (median value $102,600), 57.1% predates 1980 (28.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Should Seminole Homeowners Know About Seminole?

Key federal SDWIS metrics for OK2006720 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Seminole (OK2006720)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | OK2006720 (Local Government) | Active CWS | Last sanitary visit: 12/01/2023 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 6,899 residents | #76 in Oklahoma | Counties: Seminole |
| Served ZIP Codes | 74818, 74868 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 57.1% (28.9% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (10 qtrs) | Zero health flags target | 4000=Gross Alpha, Excl. Radon And U, 4006=Combined Uranium, 4010=Combined Radium (-226 And -228) |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Does UCMR 5 Testing Reveal About OK2006720?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Seminole in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for OK2006720

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Where Can You Compare Seminole With Other Oklahoma Systems?

Four peer Oklahoma utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Oklahoma for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Falls Creek Baptist Conference Center](https://gcsradheat.com/water-quality/oklahoma/ok1010840-falls-creek-baptist-conference-center/) (OK1010840) | Murray | 7,000 | Surface / Mixed | 0 |
| [Idabel Pwa](https://gcsradheat.com/water-quality/oklahoma/ok1010203-idabel-pwa/) (OK1010203) | Mccurtain | 6,952 | Surface / Mixed | 0 |
| [Anadarko Public Works Authority](https://gcsradheat.com/water-quality/oklahoma/ok1010806-anadarko-public-works-authority/) (OK1010806) | Caddo | 6,804 | Surface / Mixed | 0 |
| [Purcell](https://gcsradheat.com/water-quality/oklahoma/ok2004701-purcell/) (OK2004701) | Mcclain | 6,693 | Groundwater | 0 |

## When Should Seminole Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Seminole; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Common Questions for Seminole Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is tap water from Seminole surface-treated or well-sourced?

EPA ECHO classifies Seminole (OK2006720) as a Ground Water community system serving 6,899 residents across Seminole. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Did Seminole exceed EPA's 4.0 ppt PFOA or PFOS standard?

Federal UCMR 5 sampling covering 1,020 laboratory tests for Seminole reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Are pre-1980 copper solder or galvanized lines common in Seminole's ZIP codes?

Across the 1 ZIP codes served by Seminole, approximately 57.1% of residential housing units were built before 1980 (28.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Explore Oklahoma Counties, Softeners & Water Heaters

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Falls Creek Baptist Conference Center (OK1010840)→](https://gcsradheat.com/water-quality/oklahoma/ok1010840-falls-creek-baptist-conference-center/)
- [Compare Idabel Pwa (OK1010203)→](https://gcsradheat.com/water-quality/oklahoma/ok1010203-idabel-pwa/)
- [Browse All Oklahoma Community Water Utilities→](https://gcsradheat.com/water-quality/oklahoma/)
- [Inspect Oklahoma County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/oklahoma/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Tap Checklist (OK2006720)

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

Annual water heater flushing and standard sediment pre-filter + nsf 53 lead check help protect fixtures across 2 Seminole ZIP codes.
[All Oklahoma Utilities](https://gcsradheat.com/water-quality/oklahoma/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
