title: "Mayes Co Rwd # 2 (OK3004608) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/oklahoma/ok3004608-mayes-co-rwd-2/
description: "Operating under Local Government management in Mayes, Oklahoma, Mayes Co Rwd # 2 (OK3004608) serves 6,280 residents via surface water purchased. Federal."
---

Safe drinking water record · OK3004608

# Mayes Co Rwd # 2 Water Quality, PFAS & Utility Report (OK3004608)

Operating under Local Government management in Mayes, Oklahoma, Mayes Co Rwd # 2 (OK3004608) serves 6,280 residents via surface water purchased. Federal screening logs show zero EPA health violations alongside 1 monitoring/reporting notice, UCMR 5 samples measured 17.7 ppt for PFOS (exceeding the 4.0 ppt federal rule), making install nsf 58 under-sink ro or nsf 53 pfas carbon the primary home filtration takeaway.

- **EPA PWSID** : OK3004608

- **Population Served** : 6,280

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 17.7 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Local water quality & plumbing fit

Drawing surface water across Mayes, Mayes Co Rwd # 2 uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 17.7 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 21,931 housing units in Mayes Co Rwd # 2's 6 ZIP codes (median value $166,220), 51.3% predates 1980 (18.0% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Should Mayes Homeowners Know About Mayes Co Rwd # 2?

Key federal SDWIS metrics for OK3004608 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for Mayes Co Rwd # 2 (OK3004608)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | OK3004608 (Local Government) | Active CWS | Last sanitary visit: 11/01/2023 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 6,280 residents | #82 in Oklahoma | Counties: Mayes |
| Served ZIP Codes | 74036, 74337, 74352, 74361, 74362, 74467 | 6 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 51.3% (18.0% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (4 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Does UCMR 5 Testing Reveal About OK3004608?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Mayes Co Rwd # 2 in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for OK3004608

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 17.7 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Where Can You Compare Mayes Co Rwd # 2 With Other Oklahoma Systems?

Four peer Oklahoma utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in Oklahoma for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Vinita Utilities Authority](https://gcsradheat.com/water-quality/oklahoma/ok1021611-vinita-utilities-authority/) (OK1021611) | Craig | 6,472 | Surface / Mixed | 0 |
| [Stephens Co Rwd #5](https://gcsradheat.com/water-quality/oklahoma/ok2006969-stephens-co-rwd-5/) (OK2006969) | Stephens | 6,426 | Surface / Mixed | 2 |
| [Bryan Co. Rws & Swmd #2](https://gcsradheat.com/water-quality/oklahoma/ok1010604-bryan-co-rws-swmd-2/) (OK1010604) | Bryan | 6,270 | Surface / Mixed | 0 |
| [Pauls Valley](https://gcsradheat.com/water-quality/oklahoma/ok1010808-pauls-valley/) (OK1010808) | Garvin | 6,256 | Surface / Mixed | 0 |

## When Should Mayes Co Rwd # 2 Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Mayes; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Common Questions for Mayes Co Rwd # 2 Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is tap water from Mayes Co Rwd # 2 surface-treated or well-sourced?

EPA ECHO classifies Mayes Co Rwd # 2 (OK3004608) as a Surface Water Purchased community system serving 6,280 residents across Mayes. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Did Mayes Co Rwd # 2 exceed EPA's 4.0 ppt PFOA or PFOS standard?

Yes—UCMR 5 laboratory testing for OK3004608 recorded 1 PFAS detections peaking at 17.7 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Are pre-1980 copper solder or galvanized lines common in Mayes Co Rwd # 2's ZIP codes?

Across the 5 ZIP codes served by Mayes Co Rwd # 2, approximately 51.3% of residential housing units were built before 1980 (18.0% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Explore Oklahoma Counties, Softeners & Water Heaters

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Vinita Utilities Authority (OK1021611)→](https://gcsradheat.com/water-quality/oklahoma/ok1021611-vinita-utilities-authority/)
- [Compare Stephens Co Rwd #5 (OK2006969)→](https://gcsradheat.com/water-quality/oklahoma/ok2006969-stephens-co-rwd-5/)
- [Browse All Oklahoma Community Water Utilities→](https://gcsradheat.com/water-quality/oklahoma/)
- [Inspect Oklahoma County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/oklahoma/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Tap Checklist (OK3004608)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Annual water heater flushing and install nsf 58 under-sink ro or nsf 53 pfas carbon help protect fixtures across 6 Mayes ZIP codes.
[All Oklahoma Utilities](https://gcsradheat.com/water-quality/oklahoma/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)