title: "Derry Boro Muni Auth (PA5650049) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/pennsylvania/pa5650049-derry-boro-muni-auth/
description: "Homeowners connected to Derry Boro Muni Auth (PA5650049) in Westmoreland, Pennsylvania receive surface water across a 6,500-person distribution network. EPA."
---

Community water audit · PA5650049 in PA

# Derry Boro Muni Auth Water Quality, PFAS & Utility Report (PA5650049)

Homeowners connected to Derry Boro Muni Auth (PA5650049) in Westmoreland, Pennsylvania receive surface water across a 6,500-person distribution network. EPA SDWIS records document zero EPA health violations alongside 3 monitoring/reporting notices; under UCMR 5 monitoring, UCMR 5 samples measured 15.0 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 70.2% of homes across 3 served ZIP codes predate 1980.

- **EPA PWSID** : PA5650049

- **Population Served** : 6,500

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 15.0 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Derry Boro Muni Auth

Drawing surface water across Westmoreland, Derry Boro Muni Auth uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 15.0 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 8,095 housing units in Derry Boro Muni Auth's 3 ZIP codes (median value $152,200), 70.2% predates 1980 (48.2% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Derry Boro Muni Auth?

Examine Derry Boro Muni Auth's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Westmoreland.

EPA SDWA and local housing profile for Derry Boro Muni Auth (PA5650049)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | PA5650049 (Local Government) | Active CWS | Last sanitary visit: 04/02/2026 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 6,500 residents | #224 in Pennsylvania | Counties: Westmoreland |
| Served ZIP Codes | 15627, 15671, 15717 | 3 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 70.2% (48.2% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 3 rule violations (2 qtrs) | Zero health flags target | 2920=Carbon, Total, 2950=Tthm, 8000=Revised Total Coliform Rule |
| State Tap Hardness Baseline | 4.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Derry Boro Muni Auth Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify PA5650049's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA5650049

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest Pennsylvania Community System Peers?

Compare four other Pennsylvania utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Pennsylvania for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Portage Boro Muni Auth](https://gcsradheat.com/water-quality/pennsylvania/pa4110027-portage-boro-muni-auth/) (PA4110027) | Cambria | 6,500 | Surface / Mixed | 0 |
| [Monaca Boro Water Dept](https://gcsradheat.com/water-quality/pennsylvania/pa5040039-monaca-boro-water-dept/) (PA5040039) | Beaver | 6,500 | Groundwater | 0 |
| [Veolia Newberry System](https://gcsradheat.com/water-quality/pennsylvania/pa7670061-veolia-newberry-system/) (PA7670061) | York | 6,480 | Groundwater | 0 |
| [Pa American Water Steelton](https://gcsradheat.com/water-quality/pennsylvania/pa7220036-pa-american-water-steelton/) (PA7220036) | Dauphin | 6,428 | Surface / Mixed | 0 |

## When Should Derry Boro Muni Auth Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Westmoreland; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: PA5650049

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Derry Boro Muni Auth's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Derry Boro Muni Auth (PA5650049) as a Surface Water community system serving 6,500 residents across Westmoreland. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Derry Boro Muni Auth homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for PA5650049 recorded 4 PFAS detections peaking at 15.0 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Derry Boro Muni Auth?

Across the 3 ZIP codes served by Derry Boro Muni Auth, approximately 70.2% of residential housing units were built before 1980 (48.2% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Pennsylvania

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Portage Boro Muni Auth (PA4110027)→](https://gcsradheat.com/water-quality/pennsylvania/pa4110027-portage-boro-muni-auth/)
- [Compare Monaca Boro Water Dept (PA5040039)→](https://gcsradheat.com/water-quality/pennsylvania/pa5040039-monaca-boro-water-dept/)
- [Browse All Pennsylvania Community Water Utilities→](https://gcsradheat.com/water-quality/pennsylvania/)
- [Inspect Pennsylvania County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/pennsylvania/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA PA5650049 serves 6,500 people; match drinking tap filters and scale prevention to Westmoreland water.
[All Pennsylvania Utilities](https://gcsradheat.com/water-quality/pennsylvania/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)