---
title: "Littlestown Boro (PA7010022) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/pennsylvania/pa7010022-littlestown-boro/
description: "Ranked #203 of 339 major community water utilities in Pennsylvania, Littlestown Boro (PA7010022) delivers ground water to 7,300 people around Adams. Public."
---

EPA SDWA profile · PA7010022 (Pennsylvania)

# Littlestown Boro Water Quality, PFAS & Utility Report (PA7010022)

Ranked #203 of 339 major community water utilities in Pennsylvania, Littlestown Boro (PA7010022) delivers ground water to 7,300 people around Adams. Public records indicate zero EPA health violations alongside 2 monitoring/reporting notices and note that UCMR 5 samples measured 12.9 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

- **EPA PWSID** : PA7010022

- **Population Served** : 7,300

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 12.9 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for PA7010022

Because Littlestown Boro relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Pennsylvania's statewide USGS median is 4.8 GPG (Moderately Hard). UCMR 5 samples reached 12.9 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 4,489 housing units in Littlestown Boro's 1 ZIP code (median value $276,700), 54.8% predates 1980 (38.6% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define PA7010022?

These verified utility measurements pair EPA SDWIS facility data for Littlestown Boro with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Littlestown Boro (PA7010022)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | PA7010022 (Local Government) | Active CWS | Last sanitary visit: 04/25/2024 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 7,300 residents | #203 in Pennsylvania | Counties: Adams |
| Served ZIP Codes | 17340 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 54.8% (38.6% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 2 rule violations (2 qtrs) | Zero health flags target | 0700=Groundwater Rule, 2378=1, 2, 4-Trichlorobenzene |
| State Tap Hardness Baseline | 4.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Littlestown Boro PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Littlestown Boro's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA7010022

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 4.5 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 12.9 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 6.0 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in Pennsylvania?

Cross-check four peer Pennsylvania water utilities to see how Littlestown Boro ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Pennsylvania for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Maidencreek Twp Water Auth](https://gcsradheat.com/water-quality/pennsylvania/pa3060012-maidencreek-twp-water-auth/) (PA3060012) | Berks | 7,505 | Groundwater | 0 |
| [Upper Saucon Twp Water Supply](https://gcsradheat.com/water-quality/pennsylvania/pa3390077-upper-saucon-twp-water-supply/) (PA3390077) | Lehigh | 7,300 | Surface / Mixed | 0 |
| [Minersville Municipal Water Au](https://gcsradheat.com/water-quality/pennsylvania/pa3540035-minersville-municipal-water-au/) (PA3540035) | Schuylkill | 7,275 | Surface / Mixed | 0 |
| [Blythe Twp Municipal Authority](https://gcsradheat.com/water-quality/pennsylvania/pa3540017-blythe-twp-municipal-authority/) (PA3540017) | Schuylkill | 7,100 | Surface / Mixed | 0 |

## When Should Littlestown Boro Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Adams; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Littlestown Boro

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 7,300 customers under EPA ID PA7010022?

EPA ECHO classifies Littlestown Boro (PA7010022) as a Ground Water community system serving 7,300 residents across Adams. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### How do Littlestown Boro PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for PA7010022 recorded 10 PFAS detections peaking at 12.9 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### What pipe materials should homeowners served by Littlestown Boro inspect?

Across the 1 ZIP codes served by Littlestown Boro, approximately 54.8% of residential housing units were built before 1980 (38.6% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for PA

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Maidencreek Twp Water Auth (PA3060012)→](https://gcsradheat.com/water-quality/pennsylvania/pa3060012-maidencreek-twp-water-auth/)
- [Compare Upper Saucon Twp Water Supply (PA3390077)→](https://gcsradheat.com/water-quality/pennsylvania/pa3390077-upper-saucon-twp-water-supply/)
- [Browse All Pennsylvania Community Water Utilities→](https://gcsradheat.com/water-quality/pennsylvania/)
- [Inspect Pennsylvania County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/pennsylvania/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (PA)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Serving Adams via groundwater; confirm cartridge micron & NSF 53/58 certifications locally.
[All Pennsylvania Utilities](https://gcsradheat.com/water-quality/pennsylvania/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
