title: "Carlisle Water Trmt Plt (PA7210002) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/pennsylvania/pa7210002-carlisle-water-trmt-plt/
description: "Homeowners connected to Carlisle Water Trmt Plt (PA7210002) in Cumberland, Pennsylvania receive surface water across a 26,000-person distribution network. EPA."
---

Community water audit · PA7210002 in PA

# Carlisle Water Trmt Plt Water Quality, PFAS & Utility Report (PA7210002)

Homeowners connected to Carlisle Water Trmt Plt (PA7210002) in Cumberland, Pennsylvania receive surface water across a 26,000-person distribution network. EPA SDWIS records document zero EPA health violations alongside 3 monitoring/reporting notices; under UCMR 5 monitoring, UCMR 5 samples measured 11.3 ppt for PFOS (exceeding the 4.0 ppt federal rule), and 68.5% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : PA7210002

- **Population Served** : 26,000

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 11.3 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Carlisle Water Trmt Plt

Drawing surface water across Cumberland, Carlisle Water Trmt Plt uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 11.3 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 16,065 housing units in Carlisle Water Trmt Plt's 1 ZIP code (median value $221,800), 68.5% predates 1980 (44.4% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Carlisle Water Trmt Plt?

Examine Carlisle Water Trmt Plt's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Cumberland.

EPA SDWA and local housing profile for Carlisle Water Trmt Plt (PA7210002)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | PA7210002 (Local Government) | Active CWS | Last sanitary visit: 11/08/2023 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 26,000 residents | #78 in Pennsylvania | Counties: Cumberland |
| Served ZIP Codes | 17013 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 68.5% (44.4% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 3 rule violations (2 qtrs) | Zero health flags target | 0200=Surface Water Treatment Rule, 0999=Chlorine |
| State Tap Hardness Baseline | 4.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Carlisle Water Trmt Plt Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify PA7210002's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA7210002

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 5.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 11.3 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest Pennsylvania Community System Peers?

Compare four other Pennsylvania utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Pennsylvania for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Auth Of Boro Of Charleroi](https://gcsradheat.com/water-quality/pennsylvania/pa5630039-auth-of-boro-of-charleroi/) (PA5630039) | Washington | 27,000 | Surface / Mixed | 0 |
| [Horsham Water&Sewer Authority](https://gcsradheat.com/water-quality/pennsylvania/pa1460033-horsham-water-sewer-authority/) (PA1460033) | Montgomery | 26,000 | Surface / Mixed | 0 |
| [Columbia Water Co](https://gcsradheat.com/water-quality/pennsylvania/pa7360123-columbia-water-co/) (PA7360123) | Lancaster | 25,200 | Surface / Mixed | 0 |
| [Paw Glen Alsace Div](https://gcsradheat.com/water-quality/pennsylvania/pa3060088-paw-glen-alsace-div/) (PA3060088) | Berks | 24,951 | Surface / Mixed | 0 |

## When Should Carlisle Water Trmt Plt Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Cumberland; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: PA7210002

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Carlisle Water Trmt Plt's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Carlisle Water Trmt Plt (PA7210002) as a Surface Water community system serving 26,000 residents across Cumberland. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Should Carlisle Water Trmt Plt homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for PA7210002 recorded 8 PFAS detections peaking at 11.3 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Carlisle Water Trmt Plt?

Across the 1 ZIP codes served by Carlisle Water Trmt Plt, approximately 68.5% of residential housing units were built before 1980 (44.4% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Pennsylvania

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Auth Of Boro Of Charleroi (PA5630039)→](https://gcsradheat.com/water-quality/pennsylvania/pa5630039-auth-of-boro-of-charleroi/)
- [Compare Horsham Water&Sewer Authority (PA1460033)→](https://gcsradheat.com/water-quality/pennsylvania/pa1460033-horsham-water-sewer-authority/)
- [Browse All Pennsylvania Community Water Utilities→](https://gcsradheat.com/water-quality/pennsylvania/)
- [Inspect Pennsylvania County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/pennsylvania/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

EPA PA7210002 serves 26,000 people; match drinking tap filters and scale prevention to Cumberland water.
[All Pennsylvania Utilities](https://gcsradheat.com/water-quality/pennsylvania/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)