---
title: "Lititz Boro (PA7360126) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/pennsylvania/pa7360126-lititz-boro/
description: "Lititz Boro (PA7360126) is a Local Government public water utility serving 9,397 residents in Lancaster, Pennsylvania primarily from groundwater under."
---

Pennsylvania water passport · EPA PA7360126

# Lititz Boro Water Quality, PFAS & Utility Report (PA7360126)

Lititz Boro (PA7360126) is a Local Government public water utility serving 9,397 residents in Lancaster, Pennsylvania primarily from groundwater under influence of surface water. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while UCMR 5 samples measured 4.0 ppt for PFBS (exceeding the 4.0 ppt federal rule). Roughly 38.0% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : PA7360126

- **Population Served** : 9,397

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 4.0 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Lititz Boro

Drawing surface water across Lancaster, Lititz Boro uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 4.0 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 18,762 housing units in Lititz Boro's 1 ZIP code (median value $321,900), 38.0% predates 1980 (21.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Lititz Boro's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Lititz Boro's network.

EPA SDWA and local housing profile for Lititz Boro (PA7360126)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | PA7360126 (Local Government) | Active CWS | Last sanitary visit: 02/01/2024 |
| Primary Source Water | Groundwater Under Influence Of Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 9,397 residents | #157 in Pennsylvania | Counties: Lancaster |
| Served ZIP Codes | 17543 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 38.0% (21.9% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 4.8 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did PA7360126 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Lititz Boro against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for PA7360126

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Lititz Boro Compare to Peer Pennsylvania Utilities?

Review four nearby Pennsylvania community water utilities matched by service rank inside Pennsylvania's 339-utility public water catalog.

Nearby community water systems in Pennsylvania for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Myerstown Water Auth](https://gcsradheat.com/water-quality/pennsylvania/pa7380025-myerstown-water-auth/) (PA7380025) | Lebanon | 9,500 | Surface / Mixed | 0 |
| [Windber Area Auth](https://gcsradheat.com/water-quality/pennsylvania/pa4560013-windber-area-auth/) (PA4560013) | Somerset | 9,463 | Groundwater | 0 |
| [Lansford Coaldale Jt Water Aut](https://gcsradheat.com/water-quality/pennsylvania/pa3130004-lansford-coaldale-jt-water-aut/) (PA3130004) | Carbon | 9,300 | Groundwater | 0 |
| [Muni Auth Of Washington Twp](https://gcsradheat.com/water-quality/pennsylvania/pa5260009-muni-auth-of-washington-twp/) (PA5260009) | Fayette | 9,100 | Surface / Mixed | 0 |

## When Should Lititz Boro Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Lancaster; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (4.8 GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Lititz Boro (PA7360126)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Lititz Boro (PA7360126) source drinking water?

EPA ECHO classifies Lititz Boro (PA7360126) as a Groundwater Under Influence Of Surface Water community system serving 9,397 residents across Lancaster. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in Lititz Boro UCMR 5 testing?

Yes—UCMR 5 laboratory testing for PA7360126 recorded 3 PFAS detections peaking at 4.0 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### Could homes served by Lititz Boro still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Lititz Boro, approximately 38.0% of residential housing units were built before 1980 (21.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Lancaster

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Myerstown Water Auth (PA7380025)→](https://gcsradheat.com/water-quality/pennsylvania/pa7380025-myerstown-water-auth/)
- [Compare Windber Area Auth (PA4560013)→](https://gcsradheat.com/water-quality/pennsylvania/pa4560013-windber-area-auth/)
- [Browse All Pennsylvania Community Water Utilities→](https://gcsradheat.com/water-quality/pennsylvania/)
- [Inspect Pennsylvania County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/pennsylvania/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for PA7360126

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Match filters to surface water chemistry in Lancaster, PA. State hardness baseline: 4.8 GPG.
[All Pennsylvania Utilities](https://gcsradheat.com/water-quality/pennsylvania/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
