---
title: "Bjw&Sa (Sc0720003) (SC0720003) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/south-carolina/sc0720003-bjw-sa-sc0720003/
description: "Ranked #6 of 164 major community water utilities in South Carolina, Bjw&Sa (Sc0720003) (SC0720003) delivers surface water to 164,829 people around Beaufort."
---

EPA SDWA profile · SC0720003 (South Carolina)

# Bjw&Sa (Sc0720003) Water Quality, PFAS & Utility Report (SC0720003)

Ranked #6 of 164 major community water utilities in South Carolina, Bjw&Sa (Sc0720003) (SC0720003) delivers surface water to 164,829 people around Beaufort. Public records indicate zero EPA health violations alongside 1 monitoring/reporting notice and note that UCMR 5 samples measured 5.7 ppt for PFBS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

- **EPA PWSID** : SC0720003

- **Population Served** : 164,829

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 5.7 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for SC0720003

Drawing surface water across Beaufort, Bjw&Sa (Sc0720003) uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 5.7 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 12,635 housing units in Bjw&Sa (Sc0720003)'s 1 ZIP code (median value $416,700), 3.3% predates 1980 (0.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define SC0720003?

These verified utility measurements pair EPA SDWIS facility data for Bjw&Sa (Sc0720003) with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Bjw&Sa (Sc0720003) (SC0720003)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | SC0720003 (Local Government) | Active CWS | Last sanitary visit: 04/08/2026 |
| Primary Source Water | Surface Water | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 164,829 residents | #6 in South Carolina | Counties: Beaufort |
| Served ZIP Codes | 29909 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 3.3% (0.8% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 1 rule violation (1 qtrs) | Zero health flags target | 2456=Total Haloacetic Acids (Haa5) |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Bjw&Sa (Sc0720003) PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Bjw&Sa (Sc0720003)'s monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for SC0720003

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 5.6 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 5.3 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in South Carolina?

Cross-check four peer South Carolina water utilities to see how Bjw&Sa (Sc0720003) ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in South Carolina for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Grand Strand W&Sa/Bull Creek](https://gcsradheat.com/water-quality/south-carolina/sc2620004-grand-strand-w-sa-bull-creek/) (SC2620004) | Conway | 252,840 | Surface / Mixed | 0 |
| [Spartanburg Water System (Sc4210001)](https://gcsradheat.com/water-quality/south-carolina/sc4210001-spartanburg-water-system-sc4210001/) (SC4210001) | Spartanburg | 166,364 | Surface / Mixed | 0 |
| [Bcwsa Sangaree W/D (0820002)](https://gcsradheat.com/water-quality/south-carolina/sc0820002-bcwsa-sangaree-w-d-0820002/) (SC0820002) | Moncks Corner | 95,345 | Surface / Mixed | 0 |
| [Mt Pleasant Waterworks (Sc1010002)](https://gcsradheat.com/water-quality/south-carolina/sc1010002-mt-pleasant-waterworks-sc1010002/) (SC1010002) | Mount Pleasant | 91,500 | Surface / Mixed | 0 |

## When Should Bjw&Sa (Sc0720003) Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Beaufort; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Bjw&Sa (Sc0720003)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 164,829 customers under EPA ID SC0720003?

EPA ECHO classifies Bjw&Sa (Sc0720003) (SC0720003) as a Surface Water community system serving 164,829 residents across Beaufort. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Bjw&Sa (Sc0720003) PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for SC0720003 recorded 28 PFAS detections peaking at 5.7 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### What pipe materials should homeowners served by Bjw&Sa (Sc0720003) inspect?

Across the 1 ZIP codes served by Bjw&Sa (Sc0720003), approximately 3.3% of residential housing units were built before 1980 (0.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for SC

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Grand Strand W&Sa/Bull Creek (SC2620004)→](https://gcsradheat.com/water-quality/south-carolina/sc2620004-grand-strand-w-sa-bull-creek/)
- [Compare Spartanburg Water System (Sc4210001) (SC4210001)→](https://gcsradheat.com/water-quality/south-carolina/sc4210001-spartanburg-water-system-sc4210001/)
- [Browse All South Carolina Community Water Utilities→](https://gcsradheat.com/water-quality/south-carolina/)
- [Inspect South Carolina County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/south-carolina/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (SC)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Serving Beaufort via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All South Carolina Utilities](https://gcsradheat.com/water-quality/south-carolina/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
