---
title: "Dcws Ashley Phosphate (Sc1820008) (SC1820008) Water Quality"
url: https://gcsradheat.com/water-quality/south-carolina/sc1820008-dcws-ashley-phosphate-sc1820008/
description: "Supplying 26,536 customers across Dorchester, South Carolina, Dcws Ashley Phosphate (Sc1820008) (EPA ID SC1820008) relies on surface water purchased for daily."
---

Utility quality file · North Charleston, SC (SC1820008)

# Dcws Ashley Phosphate (Sc1820008) Water Quality, PFAS & Utility Report (SC1820008)

Supplying 26,536 customers across Dorchester, South Carolina, Dcws Ashley Phosphate (Sc1820008) (EPA ID SC1820008) relies on surface water purchased for daily municipal flow. Current federal compliance files record zero 3-year EPA health or monitoring rule violations on record; meanwhile UCMR 5 samples measured 7.4 ppt for PFOS (exceeding the 4.0 ppt federal rule), and 17.4% of homes across 2 served ZIP codes predate 1980.

- **EPA PWSID** : SC1820008

- **Population Served** : 26,536

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 7.4 ppt (PFOS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — SC1820008

Drawing surface water across North Charleston, Dcws Ashley Phosphate (Sc1820008) uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 7.4 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 32,919 housing units in Dcws Ashley Phosphate (Sc1820008)'s 2 ZIP codes (median value $297,600), 17.4% predates 1980 (1.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Is Dcws Ashley Phosphate (Sc1820008)'s Municipal Water Supplied and Regulated?

Review Dcws Ashley Phosphate (Sc1820008)'s supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Dcws Ashley Phosphate (Sc1820008) (SC1820008)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | SC1820008 (Local Government) | Active CWS | Last sanitary visit: 10/30/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 26,536 residents | #39 in South Carolina | Counties: Dorchester |
| Served ZIP Codes | 29420, 29485 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 17.4% (1.3% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Do Federal PFAS Lab Results Show for Dcws Ashley Phosphate (Sc1820008)?

See how Dcws Ashley Phosphate (Sc1820008) (SC1820008) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for SC1820008

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 6.4 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 7.4 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby South Carolina Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in South Carolina.

Nearby community water systems in South Carolina for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Edgefield Co W&Sa (1920001)](https://gcsradheat.com/water-quality/south-carolina/sc1920001-edgefield-co-w-sa-1920001/) (SC1920001) | North Augusta | 29,200 | Surface / Mixed | 0 |
| [Conway City Of (Sc2610008)](https://gcsradheat.com/water-quality/south-carolina/sc2610008-conway-city-of-sc2610008/) (SC2610008) | Conway | 27,005 | Surface / Mixed | 0 |
| [North Augusta City Of (Sc0210003)](https://gcsradheat.com/water-quality/south-carolina/sc0210003-north-augusta-city-of-sc0210003/) (SC0210003) | Aiken | 26,125 | Surface / Mixed | 0 |
| [Lugoff Elgin Water Auth (Sc2820001)](https://gcsradheat.com/water-quality/south-carolina/sc2820001-lugoff-elgin-water-auth-sc2820001/) (SC2820001) | Lugoff | 25,783 | Surface / Mixed | 0 |

## When Should Dcws Ashley Phosphate (Sc1820008) Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in North Charleston; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for North Charleston Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Dcws Ashley Phosphate (Sc1820008) draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Dcws Ashley Phosphate (Sc1820008) (SC1820008) as a Surface Water Purchased community system serving 26,536 residents across Dorchester. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### What did federal UCMR 5 sampling measure in SC1820008?

Yes—UCMR 5 laboratory testing for SC1820008 recorded 12 PFAS detections peaking at 7.4 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside SC1820008's service area?

Across the 2 ZIP codes served by Dcws Ashley Phosphate (Sc1820008), approximately 17.4% of residential housing units were built before 1980 (1.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related South Carolina Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Edgefield Co W&Sa (1920001) (SC1920001)→](https://gcsradheat.com/water-quality/south-carolina/sc1920001-edgefield-co-w-sa-1920001/)
- [Compare Conway City Of (Sc2610008) (SC2610008)→](https://gcsradheat.com/water-quality/south-carolina/sc2610008-conway-city-of-sc2610008/)
- [Browse All South Carolina Community Water Utilities→](https://gcsradheat.com/water-quality/south-carolina/)
- [Inspect South Carolina County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/south-carolina/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

North Charleston Tap Action

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

For 26,536 customers on surface water, focus on install nsf 58 under-sink ro or nsf 53 pfas carbon before upgrading heaters.
[All South Carolina Utilities](https://gcsradheat.com/water-quality/south-carolina/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
