---
title: "Ocoee Utility District (TN0000525) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/tennessee/tn0000525-ocoee-utility-district/
description: "Ranked #77 of 280 major community water utilities in Tennessee, Ocoee Utility District (TN0000525) delivers surface water purchased to 21,082 people around."
---

EPA SDWA profile · TN0000525 (Tennessee)

# Ocoee Utility District Water Quality, PFAS & Utility Report (TN0000525)

Ranked #77 of 280 major community water utilities in Tennessee, Ocoee Utility District (TN0000525) delivers surface water purchased to 21,082 people around Cleveland. Public records indicate zero EPA health violations alongside 2 monitoring/reporting notices and note that UCMR 5 samples measured 41.0 ppt for PFBS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

- **EPA PWSID** : TN0000525

- **Population Served** : 21,082

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 41.0 ppt (PFBS)

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for TN0000525

Drawing surface water across Cleveland, Ocoee Utility District uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 41.0 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 12,841 housing units in Ocoee Utility District's 1 ZIP code (median value $213,900), 39.7% predates 1980 (12.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## Which Compliance and Housing Indicators Define TN0000525?

These verified utility measurements pair EPA SDWIS facility data for Ocoee Utility District with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Ocoee Utility District (TN0000525)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | TN0000525 (Local Government) | Active CWS | Last sanitary visit: 05/13/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 21,082 residents | #77 in Tennessee | Counties: Bradley |
| Served ZIP Codes | 37323 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 39.7% (12.1% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 2 rule violations (12 qtrs) | Zero health flags target | 7000=Consumer Confidence Rule, 7500=Public Notice |
| State Tap Hardness Baseline | 4.5 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Ocoee Utility District PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Ocoee Utility District's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TN0000525

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 6.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 4.5 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 3.0 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in Tennessee?

Cross-check four peer Tennessee water utilities to see how Ocoee Utility District ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Tennessee for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Lafayette Water System](https://gcsradheat.com/water-quality/tennessee/tn0000373-lafayette-water-system/) (TN0000373) | Lafayette | 22,435 | Surface / Mixed | 0 |
| [Lawrenceburg Utility Systems](https://gcsradheat.com/water-quality/tennessee/tn0000392-lawrenceburg-utility-systems/) (TN0000392) | Lawrenceburg | 21,244 | Surface / Mixed | 0 |
| [Northwest Utility District](https://gcsradheat.com/water-quality/tennessee/tn0000169-northwest-utility-district/) (TN0000169) | Soddy-Daisy | 20,710 | Surface / Mixed | 0 |
| [Selmer Water System](https://gcsradheat.com/water-quality/tennessee/tn0000615-selmer-water-system/) (TN0000615) | Selmer | 20,648 | Groundwater | 0 |

## When Should Ocoee Utility District Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Cleveland; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (4.5 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Ocoee Utility District

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 21,082 customers under EPA ID TN0000525?

EPA ECHO classifies Ocoee Utility District (TN0000525) as a Surface Water Purchased community system serving 21,082 residents across Bradley. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Ocoee Utility District PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for TN0000525 recorded 15 PFAS detections peaking at 41.0 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### What pipe materials should homeowners served by Ocoee Utility District inspect?

Across the 1 ZIP codes served by Ocoee Utility District, approximately 39.7% of residential housing units were built before 1980 (12.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for TN

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Lafayette Water System (TN0000373)→](https://gcsradheat.com/water-quality/tennessee/tn0000373-lafayette-water-system/)
- [Compare Lawrenceburg Utility Systems (TN0000392)→](https://gcsradheat.com/water-quality/tennessee/tn0000392-lawrenceburg-utility-systems/)
- [Browse All Tennessee Community Water Utilities→](https://gcsradheat.com/water-quality/tennessee/)
- [Inspect Tennessee County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/tennessee/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (TN)

### Point-of-Use Reverse Osmosis (NSF/ANSI 58) or Catalytic Carbon (NSF 53)

Serving Cleveland via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All Tennessee Utilities](https://gcsradheat.com/water-quality/tennessee/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
