---
title: "City Of Sanger (TX0610006) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/texas/tx0610006-city-of-sanger/
description: "City Of Sanger (TX0610006) is a Local Government public water utility serving 10,166 residents in Denton, Texas primarily from surface water purchased. EPA."
---

Texas water passport · EPA TX0610006

# City Of Sanger Water Quality, PFAS & Utility Report (TX0610006)

City Of Sanger (TX0610006) is a Local Government public water utility serving 10,166 residents in Denton, Texas primarily from surface water purchased. EPA ECHO logs show zero EPA health violations alongside 2 monitoring/reporting notices, while all 405 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 18.3% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : TX0610006

- **Population Served** : 10,166

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for City Of Sanger

Drawing surface water across Denton, City Of Sanger uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 7,211 housing units in City Of Sanger's 1 ZIP code (median value $315,900), 18.3% predates 1980 (6.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are City Of Sanger's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in City Of Sanger's network.

EPA SDWA and local housing profile for City Of Sanger (TX0610006)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | TX0610006 (Local Government) | Active CWS | Last sanitary visit: 04/08/2026 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 10,166 residents | #411 in Texas | Counties: Denton |
| Served ZIP Codes | 76266 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 18.3% (6.1% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 2 rule violations (6 qtrs) | Zero health flags target | 5200=Lead And Copper Rule Revisions |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did TX0610006 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for City Of Sanger against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TX0610006

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does City Of Sanger Compare to Peer Texas Utilities?

Review four nearby Texas community water utilities matched by service rank inside Texas's 1,193-utility public water catalog.

Nearby community water systems in Texas for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Fort Bend County Mud 151](https://gcsradheat.com/water-quality/texas/tx0790443-fort-bend-county-mud-151/) (TX0790443) | Fort Bend | 10,233 | Groundwater | 0 |
| [Rice Wsc](https://gcsradheat.com/water-quality/texas/tx1750019-rice-wsc/) (TX1750019) | Navarro | 10,167 | Surface / Mixed | 0 |
| [Mission Bend Mud 2](https://gcsradheat.com/water-quality/texas/tx1011826-mission-bend-mud-2/) (TX1011826) | Harris | 10,155 | Groundwater | 0 |
| [Harris County Wcid 109](https://gcsradheat.com/water-quality/texas/tx1010359-harris-county-wcid-109/) (TX1010359) | Harris | 10,134 | Surface / Mixed | 0 |

## When Should City Of Sanger Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Denton; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for City Of Sanger (TX0610006)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does City Of Sanger (TX0610006) source drinking water?

EPA ECHO classifies City Of Sanger (TX0610006) as a Surface Water Purchased community system serving 10,166 residents across Denton. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### Were PFAS compounds detected in City Of Sanger UCMR 5 testing?

Federal UCMR 5 sampling covering 405 laboratory tests for City Of Sanger reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Could homes served by City Of Sanger still face lead solder or older pipe risks?

Across the 1 ZIP codes served by City Of Sanger, approximately 18.3% of residential housing units were built before 1980 (6.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Denton

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Fort Bend County Mud 151 (TX0790443)→](https://gcsradheat.com/water-quality/texas/tx0790443-fort-bend-county-mud-151/)
- [Compare Rice Wsc (TX1750019)→](https://gcsradheat.com/water-quality/texas/tx1750019-rice-wsc/)
- [Browse All Texas Community Water Utilities→](https://gcsradheat.com/water-quality/texas/)
- [Inspect Texas County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/texas/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for TX0610006

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Match filters to surface water chemistry in Denton, TX. State hardness baseline: Check CCR GPG.
[All Texas Utilities](https://gcsradheat.com/water-quality/texas/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
