---
title: "Brinker Wsc (TX1120011) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/texas/tx1120011-brinker-wsc/
description: "Ranked #1,135 of 1,193 major community water utilities in Texas, Brinker Wsc (TX1120011) delivers surface water purchased to 3,519 people around Hopkins."
---

EPA SDWA profile · TX1120011 (Texas)

# Brinker Wsc Water Quality, PFAS & Utility Report (TX1120011)

Ranked #1,135 of 1,193 major community water utilities in Texas, Brinker Wsc (TX1120011) delivers surface water purchased to 3,519 people around Hopkins. Public records indicate zero EPA health violations alongside 2 monitoring/reporting notices and note that UCMR 5 PFAS sampling is not flagged in this federal test tranche. Recommended home check: Kitchen NSF 53 catalytic carbon filter.

- **EPA PWSID** : TX1120011

- **Population Served** : 3,519

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : Not Sampled

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for TX1120011

Drawing surface water across Hopkins, Brinker Wsc uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Even when Brinker Wsc passes distribution sampling, interior plumbing installed before June 1986 can contribute brass or lead solder leachate after overnight stagnation—flushing cold kitchen lines for 30–60 seconds cuts first-draw spikes.

## Which Compliance and Housing Indicators Define TX1120011?

These verified utility measurements pair EPA SDWIS facility data for Brinker Wsc with Census housing vintage across its 0 served ZIP codes.

EPA SDWA and local housing profile for Brinker Wsc (TX1120011)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | TX1120011 (Local Government) | Active CWS | Last sanitary visit: 11/25/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 3,519 residents | #1,135 in Texas | Counties: Hopkins |
| Served ZIP Codes | Service boundary varies | 0 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | Check municipal permit date | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 2 rule violations (12 qtrs) | Zero health flags target | 7500=Public Notice |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Brinker Wsc PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Brinker Wsc's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TX1120011

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Not tested in UCMR 5 | 4.0 ppt EPA MCL | Check annual state CCR report |
| PFOS | Not tested in UCMR 5 | 4.0 ppt EPA MCL | Check annual state CCR report |
| PFHxS | Not tested in UCMR 5 | 10 ppt EPA MCL | Check annual state CCR report |
| PFNA | Not tested in UCMR 5 | 10 ppt EPA MCL | Check annual state CCR report |
| HFPO-DA | Not tested in UCMR 5 | 10 ppt EPA MCL | Check annual state CCR report |

## What Do Neighboring Community Water Systems Report in Texas?

Cross-check four peer Texas water utilities to see how Brinker Wsc ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Texas for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [City Of Reno](https://gcsradheat.com/water-quality/texas/tx1840049-city-of-reno/) (TX1840049) | Parker | 3,526 | Surface / Mixed | 0 |
| [Harris County Mud 62](https://gcsradheat.com/water-quality/texas/tx1012285-harris-county-mud-62/) (TX1012285) | Harris | 3,519 | Groundwater | 0 |
| [Williamson County Mud 10](https://gcsradheat.com/water-quality/texas/tx2460145-williamson-county-mud-10/) (TX2460145) | Williamson | 3,513 | Surface / Mixed | 0 |
| [Klein Pud](https://gcsradheat.com/water-quality/texas/tx1011143-klein-pud/) (TX1011143) | Harris | 3,504 | Groundwater | 0 |

## When Should Brinker Wsc Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Hopkins; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Brinker Wsc

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 3,519 customers under EPA ID TX1120011?

EPA ECHO classifies Brinker Wsc (TX1120011) as a Surface Water Purchased community system serving 3,519 residents across Hopkins. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Brinker Wsc PFAS levels compare to EPA's 4.0 ppt federal limit?

Brinker Wsc is outside the finalized UCMR 5 test subset in this extract (0 federal samples logged); check the utility's annual Consumer Confidence Report (CCR) or test kitchen tap water directly.

### What pipe materials should homeowners served by Brinker Wsc inspect?

Even when Brinker Wsc meets utility-side distribution targets under EPA's 10 ppb Lead and Copper Rule Improvements (LCRI), homes built before 1986 can release lead from private interior solder, brass valves, or aging galvanized laterals.

## Additional Water Softener & Code Tools for TX

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare City Of Reno (TX1840049)→](https://gcsradheat.com/water-quality/texas/tx1840049-city-of-reno/)
- [Compare Harris County Mud 62 (TX1012285)→](https://gcsradheat.com/water-quality/texas/tx1012285-harris-county-mud-62/)
- [Browse All Texas Community Water Utilities→](https://gcsradheat.com/water-quality/texas/)
- [Inspect Texas County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/texas/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (TX)

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Serving Hopkins via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All Texas Utilities](https://gcsradheat.com/water-quality/texas/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
