title: "Stanley Lake Mud (TX1700097) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/texas/tx1700097-stanley-lake-mud/
description: "Stanley Lake Mud (TX1700097) is a Local Government public water utility serving 3,783 residents in Montgomery, Texas primarily from ground water. EPA ECHO logs."
---

Texas water passport · EPA TX1700097

# Stanley Lake Mud Water Quality, PFAS & Utility Report (TX1700097)

Stanley Lake Mud (TX1700097) is a Local Government public water utility serving 3,783 residents in Montgomery, Texas primarily from ground water. EPA ECHO logs show zero 3-year EPA health or monitoring rule violations on record, while all 240 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 14.6% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : TX1700097

- **Population Served** : 3,783

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Filtration & pipe verdict for Stanley Lake Mud

Drawing surface water across Montgomery, Stanley Lake Mud uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 14,982 housing units in Stanley Lake Mud's 1 ZIP code (median value $369,200), 14.6% predates 1980 (2.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## What Are Stanley Lake Mud's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Stanley Lake Mud's network.

EPA SDWA and local housing profile for Stanley Lake Mud (TX1700097)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | TX1700097 (Local Government) | Active CWS | Last sanitary visit: 06/25/2024 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 3,783 residents | #1,056 in Texas | Counties: Montgomery |
| Served ZIP Codes | 77356 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 14.6% (2.1% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |

## Did TX1700097 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Stanley Lake Mud against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for TX1700097

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## How Does Stanley Lake Mud Compare to Peer Texas Utilities?

Review four nearby Texas community water utilities matched by service rank inside Texas's 1,193-utility public water catalog.

Nearby community water systems in Texas for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Northwest Harris County Mud 30](https://gcsradheat.com/water-quality/texas/tx1012951-northwest-harris-county-mud-30/) (TX1012951) | Harris | 3,804 | Surface / Mixed | 0 |
| [Crockett County Wcid 1 Ozona](https://gcsradheat.com/water-quality/texas/tx0530012-crockett-county-wcid-1-ozona/) (TX0530012) | Crockett | 3,800 | Groundwater | 0 |
| [City Of Springtown](https://gcsradheat.com/water-quality/texas/tx1840003-city-of-springtown/) (TX1840003) | Parker | 3,781 | Surface / Mixed | 0 |
| [Decker Hills](https://gcsradheat.com/water-quality/texas/tx1700386-decker-hills/) (TX1700386) | Montgomery | 3,780 | Groundwater | 0 |

## When Should Stanley Lake Mud Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Montgomery; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

## Homeowner Water Quality FAQs for Stanley Lake Mud (TX1700097)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Where does Stanley Lake Mud (TX1700097) source drinking water?

EPA ECHO classifies Stanley Lake Mud (TX1700097) as a Ground Water community system serving 3,783 residents across Montgomery. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Were PFAS compounds detected in Stanley Lake Mud UCMR 5 testing?

Federal UCMR 5 sampling covering 240 laboratory tests for Stanley Lake Mud reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Could homes served by Stanley Lake Mud still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Stanley Lake Mud, approximately 14.6% of residential housing units were built before 1980 (2.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Next Water Quality & State Guides for Montgomery

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Northwest Harris County Mud 30 (TX1012951)→](https://gcsradheat.com/water-quality/texas/tx1012951-northwest-harris-county-mud-30/)
- [Compare Crockett County Wcid 1 Ozona (TX0530012)→](https://gcsradheat.com/water-quality/texas/tx0530012-crockett-county-wcid-1-ozona/)
- [Browse All Texas Community Water Utilities→](https://gcsradheat.com/water-quality/texas/)
- [Inspect Texas County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/texas/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Recommended for TX1700097

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

Match filters to groundwater chemistry in Montgomery, TX. State hardness baseline: Check CCR GPG.
[All Texas Utilities](https://gcsradheat.com/water-quality/texas/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)