---
title: "Fort Eustis (VA3700100) Water Quality & PFAS"
url: https://gcsradheat.com/water-quality/virginia/va3700100-fort-eustis/
description: "Supplying 16,900 customers across Virginia, Virginia, Fort Eustis (EPA ID VA3700100) relies on surface water purchased for daily municipal flow. Current."
---

Utility quality file · Newport News City, VA (VA3700100)

# Fort Eustis Water Quality, PFAS & Utility Report (VA3700100)

Supplying 16,900 customers across Virginia, Virginia, Fort Eustis (EPA ID VA3700100) relies on surface water purchased for daily municipal flow. Current federal compliance files record zero 3-year EPA health or monitoring rule violations on record; meanwhile UCMR 5 samples measured 3.9 ppt for PFHxS (under the 4.0 ppt federal rule), and 24.3% of homes across 1 served ZIP code predate 1980.

- **EPA PWSID** : VA3700100

- **Population Served** : 16,900

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 3.9 ppt (PFHxS)

- **3-Yr Health Flags** : 0 Health Viol.

Tap treatment summary — VA3700100

Drawing surface water across Newport News City, Fort Eustis uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Detectable trace PFHxS (3.9 ppt) remains below EPA's 4.0 ppt enforcement ceiling, while activated carbon drinking filters reliably lower residual exposure.

Even when Fort Eustis passes distribution sampling, interior plumbing installed before June 1986 can contribute brass or lead solder leachate after overnight stagnation—flushing cold kitchen lines for 30–60 seconds cuts first-draw spikes.

## How Is Fort Eustis's Municipal Water Supplied and Regulated?

Review Fort Eustis's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Fort Eustis (VA3700100)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | VA3700100 (Federal Government) | Active CWS | Last sanitary visit: 03/13/2026 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 16,900 residents | #57 in Virginia | Counties: Virginia |
| Served ZIP Codes | 23604 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 24.3% (6.3% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 1.9 GPG (Soft) | >= 7.0 GPG = Hard | Moderate mineral profile |

## What Do Federal PFAS Lab Results Show for Fort Eustis?

See how Fort Eustis (VA3700100) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for VA3700100

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | 3.9 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Which Nearby Virginia Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Virginia.

Nearby community water systems in Virginia for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Radford, City Of](https://gcsradheat.com/water-quality/virginia/va1750100-radford-city-of/) (VA1750100) | Radford City | 17,420 | Surface / Mixed | 0 |
| [Naval Support Activity Portsmouth](https://gcsradheat.com/water-quality/virginia/va3740500-naval-support-activity-portsmouth/) (VA3740500) | Portsmouth City | 17,000 | Surface / Mixed | 0 |
| [Williamsburg, City Of](https://gcsradheat.com/water-quality/virginia/va3830850-williamsburg-city-of/) (VA3830850) | Williamsburg City | 16,300 | Surface / Mixed | 0 |
| [Front Royal, Town Of](https://gcsradheat.com/water-quality/virginia/va2187406-front-royal-town-of/) (VA2187406) | Warren | 15,000 | Surface / Mixed | 0 |

## When Should Fort Eustis Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Newport News City; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (1.9 GPG) and add scale inhibition on groundwater feeds.

## Practical Drinking Water Questions for Newport News City Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Fort Eustis draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Fort Eustis (VA3700100) as a Surface Water Purchased community system serving 16,900 residents across Virginia. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### What did federal UCMR 5 sampling measure in VA3700100?

Yes—UCMR 5 laboratory testing for VA3700100 recorded 3 PFAS detections peaking at 3.9 ppt (PFHxS), which sits below EPA's 4.0 ppt federal MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

### How does local home age affect plumbing risk inside VA3700100's service area?

Across the 1 ZIP codes served by Fort Eustis, approximately 24.3% of residential housing units were built before 1980 (6.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Related Virginia Pipe & Softener Links

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Radford, City Of (VA1750100)→](https://gcsradheat.com/water-quality/virginia/va1750100-radford-city-of/)
- [Compare Naval Support Activity Portsmouth (VA3740500)→](https://gcsradheat.com/water-quality/virginia/va3740500-naval-support-activity-portsmouth/)
- [Browse All Virginia Community Water Utilities→](https://gcsradheat.com/water-quality/virginia/)
- [Inspect Virginia County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/virginia/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Newport News City Tap Action

### NSF/ANSI 53 Activated Carbon Block (Trace PFAS Polishing)

For 16,900 customers on surface water, focus on consider nsf 53 drinking filter before upgrading heaters.
[All Virginia Utilities](https://gcsradheat.com/water-quality/virginia/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
