---
title: "Naval Base Kitsap At Bremerton (WA5303468) Water Quality"
url: https://gcsradheat.com/water-quality/washington/wa5303468-naval-base-kitsap-at-bremerton/
description: "Ranked #122 of 238 major community water utilities in Washington, Naval Base Kitsap At Bremerton (WA5303468) delivers surface water purchased to 11,792 people."
---

EPA SDWA profile · WA5303468 (Washington)

# Naval Base Kitsap At Bremerton Water Quality, PFAS & Utility Report (WA5303468)

Ranked #122 of 238 major community water utilities in Washington, Naval Base Kitsap At Bremerton (WA5303468) delivers surface water purchased to 11,792 people around Kitsap. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that all 120 federal UCMR 5 PFAS lab runs tested non-detect. Recommended home check: Kitchen NSF 53 catalytic carbon filter.

- **EPA PWSID** : WA5303468

- **Population Served** : 11,792

- **Water Source** : Surface Water

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Homeowner takeaway for WA5303468

Drawing surface water across Kitsap, Naval Base Kitsap At Bremerton uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Even when Naval Base Kitsap At Bremerton passes distribution sampling, interior plumbing installed before June 1986 can contribute brass or lead solder leachate after overnight stagnation—flushing cold kitchen lines for 30–60 seconds cuts first-draw spikes.

## Which Compliance and Housing Indicators Define WA5303468?

These verified utility measurements pair EPA SDWIS facility data for Naval Base Kitsap At Bremerton with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Naval Base Kitsap At Bremerton (WA5303468)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | WA5303468 (Federal Government) | Active CWS | Last sanitary visit: 06/11/2025 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 11,792 residents | #122 in Washington | Counties: Kitsap |
| Served ZIP Codes | 98314 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 71.9% (71.9% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 4.1 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## How Do Naval Base Kitsap At Bremerton PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Naval Base Kitsap At Bremerton's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for WA5303468

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## What Do Neighboring Community Water Systems Report in Washington?

Cross-check four peer Washington water utilities to see how Naval Base Kitsap At Bremerton ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Washington for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [Skyway Water & Sewer](https://gcsradheat.com/water-quality/washington/wa5338800-skyway-water-sewer/) (WA5338800) | King | 12,036 | Surface / Mixed | 0 |
| [Beacon Hill Water & Sewer District](https://gcsradheat.com/water-quality/washington/wa5315650-beacon-hill-water-sewer-district/) (WA5315650) | Cowlitz | 11,969 | Groundwater | 0 |
| [Chehalis Water Department](https://gcsradheat.com/water-quality/washington/wa5312250-chehalis-water-department/) (WA5312250) | Lewis | 11,718 | Surface / Mixed | 0 |
| [Hoquiam Water Department](https://gcsradheat.com/water-quality/washington/wa5334350-hoquiam-water-department/) (WA5334350) | Grays Harbor | 11,456 | Surface / Mixed | 0 |

## When Should Naval Base Kitsap At Bremerton Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Kitsap; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (4.1 GPG) and add scale inhibition on groundwater feeds.

## Key Questions About Tap Water From Naval Base Kitsap At Bremerton

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### What water source serves the 11,792 customers under EPA ID WA5303468?

EPA ECHO classifies Naval Base Kitsap At Bremerton (WA5303468) as a Surface Water Purchased community system serving 11,792 residents across Kitsap. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

### How do Naval Base Kitsap At Bremerton PFAS levels compare to EPA's 4.0 ppt federal limit?

Federal UCMR 5 sampling covering 120 laboratory tests for Naval Base Kitsap At Bremerton reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### What pipe materials should homeowners served by Naval Base Kitsap At Bremerton inspect?

Across the 1 ZIP codes served by Naval Base Kitsap At Bremerton, approximately 71.9% of residential housing units were built before 1980 (71.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## Additional Water Softener & Code Tools for WA

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Skyway Water & Sewer (WA5338800)→](https://gcsradheat.com/water-quality/washington/wa5338800-skyway-water-sewer/)
- [Compare Beacon Hill Water & Sewer District (WA5315650)→](https://gcsradheat.com/water-quality/washington/wa5315650-beacon-hill-water-sewer-district/)
- [Browse All Washington Community Water Utilities→](https://gcsradheat.com/water-quality/washington/)
- [Inspect Washington County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/washington/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Filter Spec (WA)

### NSF/ANSI 42/53 Carbon Block for Chloramine / Disinfection Byproducts

Serving Kitsap via surface water; confirm cartridge micron & NSF 53/58 certifications locally.
[All Washington Utilities](https://gcsradheat.com/water-quality/washington/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)
