# Middleton Waterworks Water Quality, PFAS & Utility Report (WI1130242)

Homeowners connected to Middleton Waterworks (WI1130242) in Middleton, Wisconsin receive ground water across a 23,868-person distribution network. EPA SDWIS records document zero EPA health violations alongside 3 monitoring/reporting notices; under UCMR 5 monitoring, all 360 federal UCMR 5 PFAS lab runs tested non-detect, and 32.1% of homes across 2 served ZIP codes predate 1980.

- **EPA PWSID** : WI1130242

- **Population Served** : 23,868

- **Water Source** : Groundwater

- **Max UCMR 5 PFAS** : 0 ppt Detected

- **3-Yr Health Flags** : 0 Health Viol.

Water chemistry briefing — Middleton Waterworks

Because Middleton Waterworks relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Wisconsin's statewide USGS median is 6.4 GPG (Moderately Hard). No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 21,940 housing units in Middleton Waterworks's 2 ZIP codes (median value $479,250), 32.1% predates 1980 (9.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

## How Clean and Hard Is Tap Water Supplied by Middleton Waterworks?

Examine Middleton Waterworks's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Dane.

EPA SDWA and local housing profile for Middleton Waterworks (WI1130242)

| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | WI1130242 (Local Government) | Active CWS | Last sanitary visit: 02/06/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 23,868 residents | #31 in Wisconsin | Counties: Dane |
| Served ZIP Codes | 53562, 53597 | 2 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 32.1% (9.3% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 3 rule violations (10 qtrs) | Zero health flags target | 2005=Endrin, 2010=Bhc-Gamma, 2015=Methoxychlor, 2020=Toxaphene |
| State Tap Hardness Baseline | 6.4 GPG (Moderately Hard) | >= 7.0 GPG = Hard | Moderate mineral profile |

## Are Forever Chemicals Detected in Middleton Waterworks Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify WI1130242's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for WI1130242

| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |

## Who Are the Closest Wisconsin Community System Peers?

Compare four other Wisconsin utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Wisconsin for side-by-side comparison

| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| [De Pere Waterworks Sa 1](https://gcsradheat.com/water-quality/wisconsin/wi4050453-de-pere-waterworks-sa-1/) (WI4050453) | De Pere | 25,660 | Surface / Mixed | 0 |
| [Watertown Waterworks](https://gcsradheat.com/water-quality/wisconsin/wi1280044-watertown-waterworks/) (WI1280044) | Watertown | 23,945 | Groundwater | 0 |
| [Menomonee Falls Ww - Surface Water](https://gcsradheat.com/water-quality/wisconsin/wi2680082-menomonee-falls-ww-surface-water/) (WI2680082) | Menomonee Falls | 23,867 | Surface / Mixed | 0 |
| [Franklin Water Utility](https://gcsradheat.com/water-quality/wisconsin/wi2410563-franklin-water-utility/) (WI2410563) | Franklin | 22,500 | Surface / Mixed | 0 |

## When Should Middleton Waterworks Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Middleton; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

### Key Limitations & Exclusions

- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

### Which Option Fits Your Situation?

**Pre-1980 Home or Young Family** Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.

**Installing a New Tankless Water Heater** Check tap hardness (6.4 GPG) and add scale inhibition on groundwater feeds.

## Drinking Water & Pipe Safety FAQs: WI1130242

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Middleton Waterworks's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Middleton Waterworks (WI1130242) as a Ground Water community system serving 23,868 residents across Dane. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

### Should Middleton Waterworks homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 360 laboratory tests for Middleton Waterworks reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

### Does EPA's 10 ppb LCRI lead rule apply to houses on Middleton Waterworks?

Across the 2 ZIP codes served by Middleton Waterworks, approximately 32.1% of residential housing units were built before 1980 (9.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

## State Plumbing & Water Hardness Tools for Wisconsin

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare De Pere Waterworks Sa 1 (WI4050453)→](https://gcsradheat.com/water-quality/wisconsin/wi4050453-de-pere-waterworks-sa-1/)
- [Compare Watertown Waterworks (WI1280044)→](https://gcsradheat.com/water-quality/wisconsin/wi1280044-watertown-waterworks/)
- [Browse All Wisconsin Community Water Utilities→](https://gcsradheat.com/water-quality/wisconsin/)
- [Inspect Wisconsin County Well, Freeze & Pipe Data→](https://gcsradheat.com/counties/wisconsin/)
- [Check Well Water PFAS, Radon & Filtration Guide→](https://gcsradheat.com/guides/well-water-filtration-radon-pfas/)

## Sources

1. [EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download](https://echo.epa.gov/tools/data-downloads) — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
2. [Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State](https://www.epa.gov/dwucmr/occurrence-data-unregulated-contaminant-monitoring-rule) — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
3. [PFAS National Primary Drinking Water Regulation & LCRI Overview](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
4. [Lead and Copper Rule Improvements (LCRI) & Service Line Inventories](https://www.epa.gov/ground-water-and-drinking-water/lead-and-copper-rule-improvements) — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
5. [National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg)](https://www.waterqualitydata.us/data/Result/search) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
6. [U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File](https://www2.census.gov/programs-surveys/acs/summary_file/2023/table-based-SF/) — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Protection Priority

### 5-Micron Sediment Pre-Filter + Periodic Private Tap Lead Check

EPA WI1130242 serves 23,868 people; match drinking tap filters and scale prevention to Middleton water.
[All Wisconsin Utilities](https://gcsradheat.com/water-quality/wisconsin/) [Check Softener Grain Sizing](https://gcsradheat.com/tools/water-softener-calculator/)