CAE Double-handle 3-hole washbasin mixer WaterSense Bathroom Faucet Specs (108 AB10045**150/1.5)
Engineered as a WaterSense-listed bathroom faucets series, CAE Double-handle 3-hole washbasin mixer (starting at 108 AB10045**150/1.5) operates at 1.5 GPM across 2 finish and trim variants merged cleanly under this model platform. Replacing a standard 2.2 GPM unit saves 31.8% annually on tap volume; performance passes federal WaterSense, though exceeds California Title 20 (1.2 GPM).
- Certified Rating
- 1.5 GPM
- EPAct Flow Savings
- 31.8%
- Finish SKUs Merged
- 2
- CA Title 20 Fit
- Federal Only
- Rep. SKU
- 108 AB10045**150/1.5
Stepping down from federal 2.2 GPM hardware to 1.5 GPM on CAE Double-handle 3-hole washbasin mixer delivers 31.8% lower usage per cycle—translating to 2,044 gal/yr saved for couples and 4,088 gal/yr for four-person households.
Because 55% of bathroom faucets draw relies on heated water, a 4-person home using electric water heating at $0.18/kWh saves an estimated $53/yr in electricity on top of $59/yr in municipal water and sewer charges.
Is CAE Double-handle 3-hole washbasin mixer Compliant With 2026 State Flow Caps?
Check federal EPAct ceilings versus strict California Title 20, Colorado, Washington, and New York flow limits for CAE Double-handle 3-hole washbasin mixer (108 AB10045**150/1.5) in this specification audit.
| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | CAE Double-handle 3-hole washbasin mixer | 1,944 cat. peers | Primary SKU: 108 AB10045**150/1.5 |
| Rated Hydraulic Efficiency | 1.5 GPM | 2.2 GPM EPAct | 31.8% reduction vs federal ceiling |
| State Title 20 Status | Exceeds Strict State Cap | <= 1.2 GPM | Installable outside 1.28/1.8/1.2 cap states |
| Consolidated Trim Count | 2 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Faucet | ASME A112.19.2 | Standard trapway |
What Does CAE Double-handle 3-hole washbasin mixer Save Over 10 Years?
Cumulative decade savings below quantify avoided tap gallons and combined utility bills when stepping down older fixtures to 1.5 GPM.
| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 2,044 gal/yr | $30/yr | $27/yr | $57/yr |
| 4-Person Family (US Avg Rate) | 4,088 gal/yr | $59/yr | $53/yr | $112/yr |
| 4-Person Family (High-Rate Metro, 1.5x) | 4,088 gal/yr | $88/yr | $85/yr | $173/yr |
| 10-Year Cumulative Savings (4-Person) | 40,880 gal | $590 | $530 | $1,120 |
Which Representative SKUs Are Covered Under Double-handle 3-hole washbasin mixer?
Verify representative model numbers, finish codes, and certified flow ratings consolidated cleanly under the CAE Double-handle 3-hole washbasin mixer EPA WaterSense product certificate below.
| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| 108 AB10045**150/1.5 | CAE Double-handle 3-hole washbasin mixer (Representative SKU) | 1.5 GPM | EPA WaterSense |
| 16 AB1519**150/1.5 | CAE Double-handle 3-hole washbasin mixer (Alternate Trim / Rough-In) | 1.5 GPM | EPA WaterSense |
What Comparable Bathroom Faucets Models Should You Cross-Shop?
Evaluate four comparable WaterSense bathroom faucets series ranked nearby in our catalog before finalizing valve compatibility or rough-in orders.
| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| Better Homes & Gardens BHS1 | BHS1-HW-NF0010 | 1.2 GPM | 45.5% | 3 |
| Brizo 65375LF | 65375LF* | 1.5 GPM | 54.5% | 3 |
| CAE Double-handle lavatory faucet | 37 AB1408**150/1.5 | 1.5 GPM | 31.8% | 2 |
| CAE Free-standing basin mixer | 37 AB1525**150/1.5 | 1.5 GPM | 31.8% | 5 |
When Should Homeowners Double-Check Fitment Before Installing CAE Double-handle 3-hole washbasin mixer?
Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.
Key Limitations & Exclusions
- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.
Which Option Fits Your Situation?
Homeowner & Contractor Questions: Double-handle 3-hole washbasin mixer
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does CAE Double-handle 3-hole washbasin mixer (108 AB10045**150/1.5) meet California Title 20 and federal WaterSense flow rules?
Partially—CAE Double-handle 3-hole washbasin mixer carries EPA WaterSense certification at 1.5 GPM, which passes federal rules though states capping flow at 1.2 GPM require a lower-flow trim.
What is the difference between trim variants listed under CAE Double-handle 3-hole washbasin mixer?
All 2 consolidated SKUs share identical WaterSense hydraulic specs (1.5 GPM) and differ mainly by exterior finish, handle style, or packaging.
Sources
- EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)