Skip to main content
Bathroom Faucets platform file · AB37 1023**

Dawn AB37 WaterSense Bathroom Faucet Specs (AB37 1023**)

Certified under EPA WaterSense specifications at 1.5 GPM, the Dawn AB37 platform (SKU AB37 1023**) unifies 4 finish and trim variants merged cleanly under this model platform. Households upgrading from legacy 2.2 GPM hardware cut consumption by 31.8% (~$112/yr for four people) and confirm this unit passes federal WaterSense, though exceeds California Title 20 (1.2 GPM).

Certified Rating
1.5 GPM
EPAct Flow Savings
31.8%
Finish SKUs Merged
4
CA Title 20 Fit
Federal Only
Rep. SKU
AB37 1023**
10-year water & energy math — AB37

Stepping down from federal 2.2 GPM hardware to 1.5 GPM on Dawn AB37 delivers 31.8% lower usage per cycle—translating to 2,044 gal/yr saved for couples and 4,088 gal/yr for four-person households.

Because 55% of bathroom faucets draw relies on heated water, a 4-person home using electric water heating at $0.18/kWh saves an estimated $53/yr in electricity on top of $59/yr in municipal water and sewer charges.

What Efficiency Standards Does Dawn AB37 Meet?

Review EPA WaterSense certification metrics, federal 10 CFR 430 flow ceilings, and strict state compliance rules across 4 models for Dawn AB37.

Verified EPA WaterSense & federal flow-rate benchmarks for Dawn AB37
Fixture SpecificationCertified ValueCode / Standard BenchmarkCompliance Note
Manufacturer & Series Dawn AB37 1,944 cat. peers Primary SKU: AB37 1023**
Rated Hydraulic Efficiency 1.5 GPM 2.2 GPM EPAct 31.8% reduction vs federal ceiling
State Title 20 Status Exceeds Strict State Cap <= 1.2 GPM Installable outside 1.28/1.8/1.2 cap states
Consolidated Trim Count 4 SKUs Canonical series view Finish/color variants grouped cleanly
Flush Architecture Faucet ASME A112.19.2 Standard trapway

What Are 2-Person vs. 4-Person Utility Savings for AB37 1023**?

Using national water and sewer averages alongside August 2026 residential electric pricing, this table models real annual and 10-year household utility savings from Dawn AB37.

Projected annual water, sewer, and heating savings versus federal baseline fixtures
Household / Region ScenarioWater Saved (gal/yr)Water & Sewer SavingsWater Heating DeltaTotal Annual Savings
2-Person Household (US Avg Rate) 2,044 gal/yr $30/yr $27/yr $57/yr
4-Person Family (US Avg Rate) 4,088 gal/yr $59/yr $53/yr $112/yr
4-Person Family (High-Rate Metro, 1.5x) 4,088 gal/yr $88/yr $85/yr $173/yr
10-Year Cumulative Savings (4-Person) 40,880 gal $590 $530 $1,120

What Model Numbers Belong to the AB37 Family?

Color trims and minor packaging codes do not change certified hydraulic performance; review the grouped Dawn AB37 configuration and representative SKU specifications indexed in the table below.

Finish & trim SKUs sharing the AB37 certified hydraulic design
SKU / Model NumberFinish / Trim DescriptionRated FlowCertification
AB37 1023** Dawn AB37 (Representative SKU) 1.5 GPM EPA WaterSense
AB37 1433** Dawn AB37 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
AB37 1565** Dawn AB37 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
AB37 1568** Dawn AB37 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense

How Do Other WaterSense Bathroom Faucets Stack Up Nearby?

Browse four adjacent EPA WaterSense certified bathroom faucets platforms below to cross-check rated flow efficiency, federal EPAct savings, and consolidated finish counts.

Comparable WaterSense fixture series in WaterSense Bathroom Sink Faucets
Brand & SeriesRep. SKUFlow RateSavings vs. EPActFinish SKUs
Dawn AB30 AB30 1788** 1.5 GPM 31.8% 4
Dawn AB33 AB33 1021** 1.5 GPM 31.8% 3
Dawn AB41 AB41 1470** 1.5 GPM 31.8% 3
Dawn AB72 AB72 1570** 1.5 GPM 31.8% 3

When Should Homeowners Double-Check Fitment Before Installing Dawn AB37?

Low-flow fixtures save money across 4 finish trims, but existing drain piping and static water pressure still govern real-world performance.

Key Limitations & Exclusions

  • Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
  • Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
  • Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

Which Option Fits Your Situation?

Post-1990 Copper or PEX Supply Lines Strong Fit — full flow performance and 31.8% bill reduction with clean drain slope.
Pre-1970 Cast-Iron Sewer Laterals Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

Buying & Compatibility FAQs: Dawn AB37

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Dawn AB37 (AB37 1023**) meet California Title 20 and federal WaterSense flow rules?

Partially—Dawn AB37 carries EPA WaterSense certification at 1.5 GPM, which passes federal rules though states capping flow at 1.2 GPM require a lower-flow trim.

What is the difference between trim variants listed under Dawn AB37?

All 4 consolidated SKUs share identical WaterSense hydraulic specs (1.5 GPM) and differ mainly by exterior finish, handle style, or packaging.

Sources

  1. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks