Skip to main content
WaterSense datasheet · American Standard (6145.013)

American Standard Ultima WaterSense Flushing Urinal Specs (6145.013)

Across 4 finish and trim variants merged cleanly under this model platform, the American Standard Ultima (6145.013) WaterSense flushing urinals architecture maintains a certified 0.125 GPF rating. Expect 87.5% lower flow than EPAct benchmarks (~3,832 gal/yr in a 4-person household), where it meets strict California Title 20 / CO / WA limits. Inspect full SKU variations, regional bill savings across 2-person and 4-person homes, and 154 peer flushing urinals series below.

Certified Rating
0.125 GPF
EPAct Flow Savings
87.5%
Finish SKUs Merged
4
CA Title 20 Fit
Compliant
Rep. SKU
6145.013
Engineering summary for 6145.013

Stepping down from federal 1.0 GPF hardware to 0.125 GPF on American Standard Ultima delivers 87.5% lower usage per cycle—translating to 1,916 gal/yr saved for couples and 3,832 gal/yr for four-person households.

Valve hydraulic geometry (Pressurized) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 4 consolidated trim SKUs.

Where Does American Standard Ultima Sit Against Category Baselines?

Audited against official EPA WaterSense product registries, American Standard Ultima engineering specifications below cover rated output, variant scope, and strict state compliance.

Verified EPA WaterSense & federal flow-rate benchmarks for American Standard Ultima
Fixture SpecificationCertified ValueCode / Standard BenchmarkCompliance Note
Manufacturer & Series American Standard Ultima 154 cat. peers Primary SKU: 6145.013
Rated Hydraulic Efficiency 0.125 GPF 1.0 GPF EPAct 87.5% reduction vs federal ceiling
State Title 20 Status Compliant <= 0.125 GPF Eligible in CA, CO, WA, NY & VT
Consolidated Trim Count 4 SKUs Canonical series view Finish/color variants grouped cleanly
Flush Architecture Valve ASME A112.19.2 Pressurized

Why Does Upgrading to 0.125 GPF Lower Monthly Costs?

Model estimated gallon and dollar reductions across 2-person and 4-person homes using American Standard Ultima compared with legacy federal baseline plumbing hardware.

Projected annual water, sewer, and heating savings versus federal baseline fixtures
Household / Region ScenarioWater Saved (gal/yr)Water & Sewer SavingsWater Heating DeltaTotal Annual Savings
2-Person Household (US Avg Rate) 1,916 gal/yr $28/yr $0/yr $28/yr
4-Person Family (US Avg Rate) 3,832 gal/yr $56/yr $0/yr $56/yr
4-Person Family (High-Rate Metro, 1.5x) 3,832 gal/yr $84/yr $0/yr $84/yr
10-Year Cumulative Savings (4-Person) 38,320 gal $560 $0 $560

Which Trim & Rough-In SKUs Belong to Ultima?

Confirm exact SKU ordering codes and representative finish trims sharing American Standard Ultima's EPA-certified internal valve body or trapway geometry below.

Finish & trim SKUs sharing the Ultima certified hydraulic design
SKU / Model NumberFinish / Trim DescriptionRated FlowCertification
6145.013 American Standard Ultima (Representative SKU) 0.125 GPF EPA WaterSense
6145.051 American Standard Ultima (Alternate Trim / Rough-In) 0.125 GPF EPA WaterSense
6145SM.013 American Standard Ultima (Alternate Trim / Rough-In) 0.125 GPF EPA WaterSense
6145SM.051 American Standard Ultima (Alternate Trim / Rough-In) 0.125 GPF EPA WaterSense

Which Other Brands Match American Standard Ultima's Flow Class?

Four peer flushing urinals series from our deduplicated EPA WaterSense catalog appear below for quick side-by-side flow and savings verification.

Comparable WaterSense fixture series in WaterSense Flushing Urinals
Brand & SeriesRep. SKUFlow RateSavings vs. EPActFinish SKUs
American Standard Selectronic 6061.013-xxx 0.5 GPF 87.5% 44
American Standard Side Mount 6045SM.013 0.125 GPF 87.5% 2
American Standard Washbrook 6590001USMCA.XXX 0.125 GPF 87.5% 3
American Standard Washbrook Flowise 6115.001 0.125 GPF 87.5% 11

When Should Homeowners Double-Check Fitment Before Installing American Standard Ultima?

Low-flow fixtures save money across 4 finish trims, but existing drain piping and static water pressure still govern real-world performance.

Key Limitations & Exclusions

  • Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
  • Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
  • Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

Which Option Fits Your Situation?

Post-1990 Copper or PEX Supply Lines Strong Fit — full flow performance and 87.5% bill reduction with clean drain slope.
Pre-1970 Cast-Iron Sewer Laterals Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

Common Questions About American Standard Ultima

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does American Standard Ultima (6145.013) meet California Title 20 and federal WaterSense flow rules?

Yes—American Standard Ultima carries EPA WaterSense certification at 0.125 GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

What is the difference between trim variants listed under American Standard Ultima?

All 4 consolidated SKUs share identical WaterSense hydraulic specs (0.125 GPF) and differ mainly by exterior finish, handle style, or packaging.

Sources

  1. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks