Skip to main content
WaterSense datasheet · American Standard Brands (1130130x*)

American Standard Brands Cadet WaterSense Showerhead Specs (1130130x*)

Across 5 finish and trim variants merged cleanly under this model platform, the American Standard Brands Cadet (1130130x*) WaterSense showerheads architecture maintains a certified 1.75 GPM rating. Expect 30.0% lower flow than EPAct benchmarks (~8,760 gal/yr in a 4-person household), where it meets strict California Title 20 / CO / WA limits. Inspect full SKU variations, regional bill savings across 2-person and 4-person homes, and 1,441 peer showerheads series below.

Certified Rating
1.75 GPM
EPAct Flow Savings
30.0%
Finish SKUs Merged
5
CA Title 20 Fit
Compliant
Rep. SKU
1130130x*
Engineering summary for 1130130x*

Stepping down from federal 2.5 GPM hardware to 1.75 GPM on American Standard Brands Cadet delivers 30.0% lower usage per cycle—translating to 4,380 gal/yr saved for couples and 8,760 gal/yr for four-person households.

Because 72% of showerheads draw relies on heated water, a 4-person home using electric water heating at $0.18/kWh saves an estimated $149/yr in electricity on top of $127/yr in municipal water and sewer charges.

Where Does American Standard Brands Cadet Sit Against Category Baselines?

Audited against official EPA WaterSense product registries, American Standard Brands Cadet engineering specifications below cover rated output, variant scope, and strict state compliance.

Verified EPA WaterSense & federal flow-rate benchmarks for American Standard Brands Cadet
Fixture SpecificationCertified ValueCode / Standard BenchmarkCompliance Note
Manufacturer & Series American Standard Brands Cadet 1,441 cat. peers Primary SKU: 1130130x*
Rated Hydraulic Efficiency 1.75 GPM 2.5 GPM EPAct 30.0% reduction vs federal ceiling
State Title 20 Status Compliant <= 1.8 GPM Eligible in CA, CO, WA, NY & VT
Consolidated Trim Count 5 SKUs Canonical series view Finish/color variants grouped cleanly
Flush Architecture Showerhead ASME A112.19.2 Standard trapway

Why Does Upgrading to 1.75 GPM Lower Monthly Costs?

Model estimated gallon and dollar reductions across 2-person and 4-person homes using American Standard Brands Cadet compared with legacy federal baseline plumbing hardware.

Projected annual water, sewer, and heating savings versus federal baseline fixtures
Household / Region ScenarioWater Saved (gal/yr)Water & Sewer SavingsWater Heating DeltaTotal Annual Savings
2-Person Household (US Avg Rate) 4,380 gal/yr $64/yr $74/yr $138/yr
4-Person Family (US Avg Rate) 8,760 gal/yr $127/yr $149/yr $276/yr
4-Person Family (High-Rate Metro, 1.5x) 8,760 gal/yr $190/yr $238/yr $429/yr
10-Year Cumulative Savings (4-Person) 87,600 gal $1,270 $1,490 $2,760

Which Trim & Rough-In SKUs Belong to Cadet?

Confirm exact SKU ordering codes and representative finish trims sharing American Standard Brands Cadet's EPA-certified internal valve body or trapway geometry below.

Finish & trim SKUs sharing the Cadet certified hydraulic design
SKU / Model NumberFinish / Trim DescriptionRated FlowCertification
1130130x* American Standard Brands Cadet (Representative SKU) 1.75 GPM EPA WaterSense
1130132x* American Standard Brands Cadet (Alternate Trim / Rough-In) 1.75 GPM EPA WaterSense
1674x* American Standard Brands Cadet (Alternate Trim / Rough-In) 1.75 GPM EPA WaterSense
1675x* American Standard Brands Cadet (Alternate Trim / Rough-In) 1.75 GPM EPA WaterSense
9091.512x* American Standard Brands Cadet (Alternate Trim / Rough-In) 1.75 GPM EPA WaterSense

Which Other Brands Match American Standard Brands Cadet's Flow Class?

Four peer showerheads series from our deduplicated EPA WaterSense catalog appear below for quick side-by-side flow and savings verification.

Comparable WaterSense fixture series in WaterSense Showerheads
Brand & SeriesRep. SKUFlow RateSavings vs. EPActFinish SKUs
American Standard Brands Berwick TU430.507x* 1.75 GPM 30.0% 4
American Standard Brands Boulevard TU431.507x* 1.75 GPM 30.0% 2
American Standard Brands Canis 1660.9 1.8 GPM 28.0% 2
American Standard Brands Chatfield 7413.501x* 1.8 GPM 28.0% 3

When Should Homeowners Double-Check Fitment Before Installing American Standard Brands Cadet?

Low-flow fixtures save money across 5 finish trims, but existing drain piping and static water pressure still govern real-world performance.

Key Limitations & Exclusions

  • Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
  • Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
  • Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

Which Option Fits Your Situation?

Post-1990 Copper or PEX Supply Lines Strong Fit — full flow performance and 30.0% bill reduction with clean drain slope.
Pre-1970 Cast-Iron Sewer Laterals Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

Common Questions About American Standard Brands Cadet

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does American Standard Brands Cadet (1130130x*) meet California Title 20 and federal WaterSense flow rules?

Yes—American Standard Brands Cadet carries EPA WaterSense certification at 1.75 GPM, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

What is the difference between trim variants listed under American Standard Brands Cadet?

All 5 consolidated SKUs share identical WaterSense hydraulic specs (1.75 GPM) and differ mainly by exterior finish, handle style, or packaging.

Sources

  1. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks