Skip to main content
WaterSense datasheet · Chicago Faucets (SH-PB1-00-030)

Chicago Faucets SH-PB1 WaterSense Showerhead Specs (SH-PB1-00-030)

Across 212 finish and trim variants merged cleanly under this model platform, the Chicago Faucets SH-PB1 (SH-PB1-00-030) WaterSense showerheads architecture maintains a certified 1.5 GPM rating. Expect 40.0% lower flow than EPAct benchmarks (~11,680 gal/yr in a 4-person household), where it meets strict California Title 20 / CO / WA limits. Inspect full SKU variations, regional bill savings across 2-person and 4-person homes, and 1,441 peer showerheads series below.

Certified Rating
1.5 GPM
EPAct Flow Savings
40.0%
Finish SKUs Merged
212
CA Title 20 Fit
Compliant
Rep. SKU
SH-PB1-00-030
Engineering summary for SH-PB1-00-030

Stepping down from federal 2.5 GPM hardware to 1.5 GPM on Chicago Faucets SH-PB1 delivers 40.0% lower usage per cycle—translating to 5,840 gal/yr saved for couples and 11,680 gal/yr for four-person households.

Because 72% of showerheads draw relies on heated water, a 4-person home using electric water heating at $0.18/kWh saves an estimated $199/yr in electricity on top of $169/yr in municipal water and sewer charges.

Where Does Chicago Faucets SH-PB1 Sit Against Category Baselines?

Audited against official EPA WaterSense product registries, Chicago Faucets SH-PB1 engineering specifications below cover rated output, variant scope, and strict state compliance.

Verified EPA WaterSense & federal flow-rate benchmarks for Chicago Faucets SH-PB1
Fixture SpecificationCertified ValueCode / Standard BenchmarkCompliance Note
Manufacturer & Series Chicago Faucets SH-PB1 1,441 cat. peers Primary SKU: SH-PB1-00-030
Rated Hydraulic Efficiency 1.5 GPM 2.5 GPM EPAct 40.0% reduction vs federal ceiling
State Title 20 Status Compliant <= 1.8 GPM Eligible in CA, CO, WA, NY & VT
Consolidated Trim Count 212 SKUs Canonical series view Finish/color variants grouped cleanly
Flush Architecture Showerhead ASME A112.19.2 Standard trapway

Why Does Upgrading to 1.5 GPM Lower Monthly Costs?

Model estimated gallon and dollar reductions across 2-person and 4-person homes using Chicago Faucets SH-PB1 compared with legacy federal baseline plumbing hardware.

Projected annual water, sewer, and heating savings versus federal baseline fixtures
Household / Region ScenarioWater Saved (gal/yr)Water & Sewer SavingsWater Heating DeltaTotal Annual Savings
2-Person Household (US Avg Rate) 5,840 gal/yr $85/yr $99/yr $184/yr
4-Person Family (US Avg Rate) 11,680 gal/yr $169/yr $199/yr $368/yr
4-Person Family (High-Rate Metro, 1.5x) 11,680 gal/yr $254/yr $318/yr $572/yr
10-Year Cumulative Savings (4-Person) 116,800 gal $1,690 $1,990 $3,680

Which Trim & Rough-In SKUs Belong to SH-PB1?

Confirm exact SKU ordering codes and representative finish trims sharing Chicago Faucets SH-PB1's EPA-certified internal valve body or trapway geometry below.

Finish & trim SKUs sharing the SH-PB1 certified hydraulic design
SKU / Model NumberFinish / Trim DescriptionRated FlowCertification
SH-PB1-00-030 Chicago Faucets SH-PB1 (Representative SKU) 1.5 GPM EPA WaterSense
SH-PB1-00-031 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-032 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-033 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-034 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-040 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-041 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-042 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-043 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense
SH-PB1-00-044 Chicago Faucets SH-PB1 (Alternate Trim / Rough-In) 1.5 GPM EPA WaterSense

Which Other Brands Match Chicago Faucets SH-PB1's Flow Class?

Four peer showerheads series from our deduplicated EPA WaterSense catalog appear below for quick side-by-side flow and savings verification.

Comparable WaterSense fixture series in WaterSense Showerheads
Brand & SeriesRep. SKUFlow RateSavings vs. EPActFinish SKUs
Chicago Faucets 1905 1905-620LCP 1.5 GPM 40.0% 4
Chicago Faucets 1907 1907-105119CP 1.5 GPM 40.0% 6
Chicago Faucets SH-PB4 SH-PB4-00-040 1.5 GPM 40.0% 20
Chicago Faucets SH-PB5 SH-PB5-00-040 1.5 GPM 40.0% 15

When Should Homeowners Double-Check Fitment Before Installing Chicago Faucets SH-PB1?

Low-flow fixtures save money across 212 finish trims, but existing drain piping and static water pressure still govern real-world performance.

Key Limitations & Exclusions

  • Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
  • Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
  • Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

Which Option Fits Your Situation?

Post-1990 Copper or PEX Supply Lines Strong Fit — full flow performance and 40.0% bill reduction with clean drain slope.
Pre-1970 Cast-Iron Sewer Laterals Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

Common Questions About Chicago Faucets SH-PB1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Chicago Faucets SH-PB1 (SH-PB1-00-030) meet California Title 20 and federal WaterSense flow rules?

Yes—Chicago Faucets SH-PB1 carries EPA WaterSense certification at 1.5 GPM, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

What is the difference between trim variants listed under Chicago Faucets SH-PB1?

All 212 consolidated SKUs share identical WaterSense hydraulic specs (1.5 GPM) and differ mainly by exterior finish, handle style, or packaging.

Sources

  1. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks