Skip to main content
Toilets platform file · MS448124CUMF(G)

Toto Aquia IV 1G ARC WaterSense Toilet Specs (MS448124CUMF(G))

Certified under EPA WaterSense specifications at 1.00 Full/0.80 Reduced (Dual-Flush) GPF, the Toto Aquia IV 1G ARC platform (SKU MS448124CUMF(G)) unifies 2 finish and trim variants merged cleanly under this model platform. Households upgrading from legacy 1.6 GPF hardware cut consumption by 37.5% (~$64/yr for four people) and confirm this unit meets strict California Title 20 / CO / WA limits.

Certified Rating
1.00 Full/0.80 Reduced (Dual-Flush) GPF
EPAct Flow Savings
37.5%
Finish SKUs Merged
2
CA Title 20 Fit
Compliant
Rep. SKU
MS448124CUMF(G)
10-year water & energy math — Aquia IV 1G ARC

Stepping down from federal 1.6 GPF hardware to 1.00 Full/0.80 Reduced (Dual-Flush) GPF on Toto Aquia IV 1G ARC delivers 37.5% lower usage per cycle—translating to 2,190 gal/yr saved for couples and 4,380 gal/yr for four-person households.

Dual hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 2 consolidated trim SKUs.

What Efficiency Standards Does Toto Aquia IV 1G ARC Meet?

Review EPA WaterSense certification metrics, federal 10 CFR 430 flow ceilings, and strict state compliance rules across 2 models for Toto Aquia IV 1G ARC.

Verified EPA WaterSense & federal flow-rate benchmarks for Toto Aquia IV 1G ARC
Fixture SpecificationCertified ValueCode / Standard BenchmarkCompliance Note
Manufacturer & Series Toto Aquia IV 1G ARC 807 cat. peers Primary SKU: MS448124CUMF(G)
Rated Hydraulic Efficiency 1.00 Full/0.80 Reduced (Dual-Flush) GPF 1.6 GPF EPAct 37.5% reduction vs federal ceiling
State Title 20 Status Compliant <= 1.28 GPF Eligible in CA, CO, WA, NY & VT
Consolidated Trim Count 2 SKUs Canonical series view Finish/color variants grouped cleanly
Flush Architecture Dual ASME A112.19.2 Gravity
Matched Bowl / Tank SKUs CT446CUF(G)(T40) ST448UM(A) Verify rough-in (10 or 12 in.) before purchase

What Are 2-Person vs. 4-Person Utility Savings for MS448124CUMF(G)?

Using national water and sewer averages alongside August 2026 residential electric pricing, this table models real annual and 10-year household utility savings from Toto Aquia IV 1G ARC.

Projected annual water, sewer, and heating savings versus federal baseline fixtures
Household / Region ScenarioWater Saved (gal/yr)Water & Sewer SavingsWater Heating DeltaTotal Annual Savings
2-Person Household (US Avg Rate) 2,190 gal/yr $32/yr $0/yr $32/yr
4-Person Family (US Avg Rate) 4,380 gal/yr $64/yr $0/yr $64/yr
4-Person Family (High-Rate Metro, 1.5x) 4,380 gal/yr $96/yr $0/yr $96/yr
10-Year Cumulative Savings (4-Person) 43,800 gal $640 $0 $640

What Model Numbers Belong to the Aquia IV 1G ARC Family?

Color trims and minor packaging codes do not change certified hydraulic performance; review the grouped Toto Aquia IV 1G ARC configuration and representative SKU specifications indexed in the table below.

Finish & trim SKUs sharing the Aquia IV 1G ARC certified hydraulic design
SKU / Model NumberFinish / Trim DescriptionRated FlowCertification
MS448124CUMF(G) Toto Aquia IV 1G ARC (Representative SKU) 1.00 Full/0.80 Reduced (Dual-Flush) GPF EPA WaterSense
MW4483056CUMF(G)(A) Toto Aquia IV 1G ARC (Alternate Trim / Rough-In) 1.00 Full/0.80 Reduced (Dual-Flush) GPF EPA WaterSense

How Do Other WaterSense Toilets Stack Up Nearby?

Browse four adjacent EPA WaterSense certified toilets platforms below to cross-check rated flow efficiency, federal EPAct savings, and consolidated finish counts.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets
Brand & SeriesRep. SKUFlow RateSavings vs. EPActFinish SKUs
Toto Aquia CST654MF(G) 1.60 Full/1.10 Reduced (Dual-Flush) GPF 0.0% 2
Toto Aquia IV CST446CEMF(G) 1.28 Full/0.90 Reduced (Dual-Flush) GPF 37.5% 46
Toto Aquia IV Arc ® MS448124CEMF(G)N 1.28 Full/0.90 Reduced (Dual-Flush) GPF 20.0% 7
Toto Aquia IV Cube® MS436124CEMF(G)N 1.28 Full/0.90 Reduced (Dual-Flush) GPF 20.0% 8

When Should Homeowners Double-Check Fitment Before Installing Toto Aquia IV 1G ARC?

Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.

Key Limitations & Exclusions

  • Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
  • Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
  • Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

Which Option Fits Your Situation?

Post-1990 Copper or PEX Supply Lines Strong Fit — full flow performance and 37.5% bill reduction with clean drain slope.
Pre-1970 Cast-Iron Sewer Laterals Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

Buying & Compatibility FAQs: Toto Aquia IV 1G ARC

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Toto Aquia IV 1G ARC (MS448124CUMF(G)) meet California Title 20 and federal WaterSense flow rules?

Yes—Toto Aquia IV 1G ARC carries EPA WaterSense certification at 1.00 Full/0.80 Reduced (Dual-Flush) GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

What is the difference between trim variants listed under Toto Aquia IV 1G ARC?

All 2 consolidated SKUs share identical WaterSense hydraulic specs (1.00 Full/0.80 Reduced (Dual-Flush) GPF) and differ mainly by exterior finish, handle style, or packaging.

Sources

  1. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)