Skip to main content
Toilets platform file · 4688-UR-XX

Villeroy & Boch Architectura WaterSense Toilet Specs (4688-UR-XX)

Certified under EPA WaterSense specifications at 1.60 Full/0.80 Reduced (Dual-Flush) GPF, the Villeroy & Boch Architectura platform (SKU 4688-UR-XX) unifies 5 finish and trim variants merged cleanly under this model platform. Households upgrading from legacy 1.6 GPF hardware cut consumption by 20.0% (~$34/yr for four people) and confirm this unit meets strict California Title 20 / CO / WA limits.

Certified Rating
1.60 Full/0.80 Reduced (Dual-Flush) GPF
EPAct Flow Savings
20.0%
Finish SKUs Merged
5
CA Title 20 Fit
Compliant
Rep. SKU
4688-UR-XX
10-year water & energy math — Architectura

Stepping down from federal 1.6 GPF hardware to 1.60 Full/0.80 Reduced (Dual-Flush) GPF on Villeroy & Boch Architectura delivers 20.0% lower usage per cycle—translating to 1,168 gal/yr saved for couples and 2,336 gal/yr for four-person households.

Dual hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 5 consolidated trim SKUs.

What Efficiency Standards Does Villeroy & Boch Architectura Meet?

Review EPA WaterSense certification metrics, federal 10 CFR 430 flow ceilings, and strict state compliance rules across 5 models for Villeroy & Boch Architectura.

Verified EPA WaterSense & federal flow-rate benchmarks for Villeroy & Boch Architectura
Fixture SpecificationCertified ValueCode / Standard BenchmarkCompliance Note
Manufacturer & Series Villeroy & Boch Architectura 807 cat. peers Primary SKU: 4688-UR-XX
Rated Hydraulic Efficiency 1.60 Full/0.80 Reduced (Dual-Flush) GPF 1.6 GPF EPAct 20.0% reduction vs federal ceiling
State Title 20 Status Compliant <= 1.28 GPF Eligible in CA, CO, WA, NY & VT
Consolidated Trim Count 5 SKUs Canonical series view Finish/color variants grouped cleanly
Flush Architecture Dual ASME A112.19.2 Gravity
Matched Bowl / Tank SKUs 4688-UR-XX, 5645-YY-XX, 5646-YY-XX, 5684-YY-XX GEBERIT 111.335.00.5, 7757-U1-XX, 7757-V1-XX, 7757 YY-XX Verify rough-in (10 or 12 in.) before purchase

What Are 2-Person vs. 4-Person Utility Savings for 4688-UR-XX?

Using national water and sewer averages alongside August 2026 residential electric pricing, this table models real annual and 10-year household utility savings from Villeroy & Boch Architectura.

Projected annual water, sewer, and heating savings versus federal baseline fixtures
Household / Region ScenarioWater Saved (gal/yr)Water & Sewer SavingsWater Heating DeltaTotal Annual Savings
2-Person Household (US Avg Rate) 1,168 gal/yr $17/yr $0/yr $17/yr
4-Person Family (US Avg Rate) 2,336 gal/yr $34/yr $0/yr $34/yr
4-Person Family (High-Rate Metro, 1.5x) 2,336 gal/yr $51/yr $0/yr $51/yr
10-Year Cumulative Savings (4-Person) 23,360 gal $340 $0 $340

What Model Numbers Belong to the Architectura Family?

Color trims and minor packaging codes do not change certified hydraulic performance; review the grouped Villeroy & Boch Architectura configuration and representative SKU specifications indexed in the table below.

Finish & trim SKUs sharing the Architectura certified hydraulic design
SKU / Model NumberFinish / Trim DescriptionRated FlowCertification
4688-UR-XX Villeroy & Boch Architectura (Representative SKU) 1.60 Full/0.80 Reduced (Dual-Flush) GPF EPA WaterSense
5645-YY-XX Villeroy & Boch Architectura (Alternate Trim / Rough-In) 1.60 Full/0.80 Reduced (Dual-Flush) GPF EPA WaterSense
5646-YY-XX Villeroy & Boch Architectura (Alternate Trim / Rough-In) 1.60 Full/0.80 Reduced (Dual-Flush) GPF EPA WaterSense
5684-YY-XX Villeroy & Boch Architectura (Alternate Trim / Rough-In) 1.60 Full/0.80 Reduced (Dual-Flush) GPF EPA WaterSense

How Do Other WaterSense Toilets Stack Up Nearby?

Browse four adjacent EPA WaterSense certified toilets platforms below to cross-check rated flow efficiency, federal EPAct savings, and consolidated finish counts.

Comparable WaterSense fixture series in WaterSense Tank-Type Toilets
Brand & SeriesRep. SKUFlow RateSavings vs. EPActFinish SKUs
Universal Rundle UR-175 N/A 1.28 GPF 20.0% 2
Universal Rundle UR-275 N/A 1.28 GPF 20.0% 2
Villeroy & Boch Marathon II N/A 1.60 Full/1.10 Reduced (Dual-Flush) GPF 0.0% 2
Villeroy & Boch Subway 4609-UR-XX 1.60 Full/0.80 Reduced (Dual-Flush) GPF 0.0% 5

When Should Homeowners Double-Check Fitment Before Installing Villeroy & Boch Architectura?

Low-flow fixtures save money across 5 finish trims, but existing drain piping and static water pressure still govern real-world performance.

Key Limitations & Exclusions

  • Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
  • Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
  • Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.

Which Option Fits Your Situation?

Post-1990 Copper or PEX Supply Lines Strong Fit — full flow performance and 20.0% bill reduction with clean drain slope.
Pre-1970 Cast-Iron Sewer Laterals Moderate Fit — verify camera inspection before pairing with sub-1.1 GPF fixtures.

Buying & Compatibility FAQs: Villeroy & Boch Architectura

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Villeroy & Boch Architectura (4688-UR-XX) meet California Title 20 and federal WaterSense flow rules?

Yes—Villeroy & Boch Architectura carries EPA WaterSense certification at 1.60 Full/0.80 Reduced (Dual-Flush) GPF, which meets strict 2026 state limits in CA, CO, WA, NY, and VT.

What is the difference between trim variants listed under Villeroy & Boch Architectura?

All 5 consolidated SKUs share identical WaterSense hydraulic specs (1.60 Full/0.80 Reduced (Dual-Flush) GPF) and differ mainly by exterior finish, handle style, or packaging.

Sources

  1. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks