Vortens™ Vienna Victory WaterSense Toilet Specs (3209/3420)
Across 2 finish and trim variants merged cleanly under this model platform, the Vortens™ Vienna Victory (3209/3420) WaterSense toilets architecture maintains a certified 1.60 Full/1.10 Reduced (Dual-Flush) GPF rating. Expect 0.0% lower flow than EPAct benchmarks (~0 gal/yr in a 4-person household), where it passes federal WaterSense, though exceeds California Title 20 (1.28 GPF).
- Certified Rating
- 1.60 Full/1.10 Reduced (Dual-Flush) GPF
- EPAct Flow Savings
- 0.0%
- Finish SKUs Merged
- 2
- CA Title 20 Fit
- Federal Only
- Rep. SKU
- 3209/3420
Stepping down from federal 1.6 GPF hardware to 1.60 Full/1.10 Reduced (Dual-Flush) GPF on Vortens™ Vienna Victory delivers 0.0% lower usage per cycle—translating to 0 gal/yr saved for couples and 0 gal/yr for four-person households.
Dual hydraulic geometry (Gravity) preserves bowl clear-out while clearing Title 20 and WaterSense MaP testing across 2 consolidated trim SKUs.
Where Does Vortens™ Vienna Victory Sit Against Category Baselines?
Audited against official EPA WaterSense product registries, Vortens™ Vienna Victory engineering specifications below cover rated output, variant scope, and strict state compliance.
| Fixture Specification | Certified Value | Code / Standard Benchmark | Compliance Note |
|---|---|---|---|
| Manufacturer & Series | Vortens™ Vienna Victory | 807 cat. peers | Primary SKU: 3209/3420 |
| Rated Hydraulic Efficiency | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | 1.6 GPF EPAct | 0.0% reduction vs federal ceiling |
| State Title 20 Status | Exceeds Strict State Cap | <= 1.28 GPF | Installable outside 1.28/1.8/1.2 cap states |
| Consolidated Trim Count | 2 SKUs | Canonical series view | Finish/color variants grouped cleanly |
| Flush Architecture | Dual | ASME A112.19.2 | Gravity |
| Matched Bowl / Tank SKUs | 3209-V | 3420-V, 3436-V | Verify rough-in (10 or 12 in.) before purchase |
Why Does Upgrading to 1.60 Full/1.10 Reduced (Dual-Flush) GPF Lower Monthly Costs?
Model estimated gallon and dollar reductions across 2-person and 4-person homes using Vortens™ Vienna Victory compared with legacy federal baseline plumbing hardware.
| Household / Region Scenario | Water Saved (gal/yr) | Water & Sewer Savings | Water Heating Delta | Total Annual Savings |
|---|---|---|---|---|
| 2-Person Household (US Avg Rate) | 0 gal/yr | $0/yr | $0/yr | $0/yr |
| 4-Person Family (US Avg Rate) | 0 gal/yr | $0/yr | $0/yr | $0/yr |
| 4-Person Family (High-Rate Metro, 1.5x) | 0 gal/yr | $0/yr | $0/yr | $0/yr |
| 10-Year Cumulative Savings (4-Person) | 0 gal | $0 | $0 | $0 |
Which Trim & Rough-In SKUs Belong to Vienna Victory?
Confirm exact SKU ordering codes and representative finish trims sharing Vortens™ Vienna Victory's EPA-certified internal valve body or trapway geometry below.
| SKU / Model Number | Finish / Trim Description | Rated Flow | Certification |
|---|---|---|---|
| 3209/3420 | Vortens™ Vienna Victory (Representative SKU) | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | EPA WaterSense |
| 3209/3436 | Vortens™ Vienna Victory (Alternate Trim / Rough-In) | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | EPA WaterSense |
Which Other Brands Match Vortens™ Vienna Victory's Flow Class?
Four peer toilets series from our deduplicated EPA WaterSense catalog appear below for quick side-by-side flow and savings verification.
| Brand & Series | Rep. SKU | Flow Rate | Savings vs. EPAct | Finish SKUs |
|---|---|---|---|---|
| Vortens™ Tornado | 3134/3468 | 1.00 GPF | 37.5% | 2 |
| Vortens™ Tornado EL | 3138/3468 | 1.00 GPF | 37.5% | 2 |
| WaterRidge® C531092 | C21083C | 1.60 Full/1.10 Reduced (Dual-Flush) GPF | 20.0% | 3 |
| WaterRidge® Globe Union | C211212 | 1.28 GPF | 20.0% | 2 |
When Should Homeowners Double-Check Fitment Before Installing Vortens™ Vienna Victory?
Low-flow fixtures save money across 2 finish trims, but existing drain piping and static water pressure still govern real-world performance.
Key Limitations & Exclusions
- Older cast-iron or nearly flat 1/4-inch-per-foot horizontal drain runs can struggle if solid waste outpaces ultra-low-flow flush volumes.
- Houses on low well-pump pressure (<30 PSI) may experience weak spray coverage with 1.5 GPM showerheads.
- Always verify rough-in valve brand match before ordering replacement trim-only kits or showerheads.
Which Option Fits Your Situation?
Common Questions About Vortens™ Vienna Victory
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Vortens™ Vienna Victory (3209/3420) meet California Title 20 and federal WaterSense flow rules?
Partially—Vortens™ Vienna Victory carries EPA WaterSense certification at 1.60 Full/1.10 Reduced (Dual-Flush) GPF, which passes federal rules though states capping flow at 1.28 GPF require a lower-flow trim.
What is the difference between trim variants listed under Vortens™ Vienna Victory?
All 2 consolidated SKUs share identical WaterSense hydraulic specs (1.60 Full/1.10 Reduced (Dual-Flush) GPF) and differ mainly by exterior finish, handle style, or packaging.
Sources
- EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)