Skip to main content
OEM part specification · Kohler

Kohler GP876851 Unified Rite-Temp Mixer & Pressure-Balancing Cartridge

OEM specification for Kohler GP876851: built for Modern Kohler K-8304 Rite-Temp single-handle pressure-balance shower rough-in valves (All-in-one ceramic disc mixer + diaphragm pressure-balance cartridge), identifiable by Rotate-only single handle (off -> cold -> warm -> hot). Verify exact stem geometry (Single integrated black/grey cartridge with red high-temp limit collar) and shut off hot and cold isolation stops before removing retaining clips.

OEM Part Number
GP876851
Operating / Join Action
Rotate-only single handle
Retainer / Seal Style
2-screw polymer mounting ring over K-8304 brass body
Compatible Series
1 Platform
Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip
Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip
How to tell this part apart

Mechanical checks for Kohler GP876851: motion — Rotate-only single handle (off -> cold -> warm -> hot); retainer — 2-screw polymer mounting ring over K-8304 brass body. Stem cue: Single integrated black/grey cartridge with red high-temp limit collar.

NOT compatible with legacy K-304 2-piece valves (which use GP800820 + GP77759).

How Do You Identify the Kohler GP876851 Retainer?

Verify handle motion (Rotate-only single handle) and retaining hardware (2-screw polymer mounting ring over K-8304 brass body) under the trim plate before pulling the cartridge or shutting off supply stops.

Shower Valve Cartridge Retainer Identification Diagram Side-by-side schematic comparing top wire U-clip (Moen 1222/1225), threaded bonnet nut (Delta RP46074/RP19804), and 4-bolt plate (Kohler Rite-Temp). 1. Top Wire U-Clip Moen 1222 / 1225 Pull U-clip upward; oval grommets (1222) 2. Threaded Bonnet Nut Delta RP46074 / RP19804 Grey cap = Post-2007 | White = Pre-2006 3. 4-Bolt Pressure Plate Kohler K-304 / K-8304 2-pc GP800820+PBU or 1-pc GP876851
Mechanical retainer anatomy: verify retainer style and handle action (rotate-only vs. pull-turn) before shutting water off or ordering OEM cartridges.

What Valves Fit Kohler GP876851?

Review complete OEM fitment specifications, body construction, non-interchangeable warnings, and federal WaterSense flow ceilings (45,604 certified fixtures) for GP876851 below.

Verified OEM technical attributes for Kohler GP876851
AttributeVerified Specification
Primary ApplicationModern Kohler K-8304 Rite-Temp single-handle pressure-balance shower rough-in valves
Handle ActionRotate-only single handle (off -> cold -> warm -> hot)
Retainer Mechanism2-screw polymer mounting ring over K-8304 brass body
Body & Seal ConstructionAll-in-one ceramic disc mixer + diaphragm pressure-balance cartridge
Stem / Fitment NoteSingle integrated black/grey cartridge with red high-temp limit collar
Compatible Valve PlatformsKohler K-8304-KS, K-8304-PX, K-8304-UX, K-P8304 rough-in bodies
Non-Interchangeable WarningNOT compatible with legacy K-304 2-piece valves (which use GP800820 + GP77759).
Federal Fixture Flow RulesFaucets ≤2.2 gpm @ 60 psi under 10 CFR 430.32(o); WaterSense ≤1.5 gpm across 45,604 certified fixtures

How Does GP876851 Compare to Peer OEM Parts?

Cross-check 6 adjacent residential OEM shower cartridges, push-to-connect couplings, and RPZ backflow repair assemblies to avoid incompatible part orders.

Cross-reference matrix of indexed residential OEM cartridges, connectors, and backflow kits
Brand & Part #ApplicationHandle / Join ActionRetainer Mechanism
Kohler GP800820 / GP500520 Kohler Rite-Temp K-304 and K-8304 shower valves Rotate-only single handle 4-bolt stainless plate
Kohler GP77759 Legacy Kohler K-304 pressure-balancing rear unit Works behind GP800820 rotate-only mixer cap 4-bolt stainless steel face plate compressing GP800820 onto GP77759
Kohler GP1092203 / GP77005-RP Two-handle Kohler ceramic disc sink faucets Quarter-turn 90-degree lever open/close Threaded brass bonnet collar
Kohler GP1059291 Kohler AquaPiston toilet canister flush seal Vertical canister lift triggered by trip lever chain Grooved retention lip around yellow/black central canister base
Moen 1222 Posi-Temp tub and shower pressure-balancing valves Rotate-only Vertical wire/U-clip inserted through top of brass valve body
Moen 1225 Single-handle kitchen, bath, and Chateau shower faucets Pull out for volume, turn left/right for temperature Top brass/wire retainer clip behind escutcheon sleeve

What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Which rough-in valves fit Kohler GP876851?

Kohler GP876851 fits Kohler K-8304-KS, K-8304-PX, K-8304-UX, K-P8304 rough-in bodies. Cross-check All-in-one ceramic disc mixer + diaphragm pressure-balance cartridge before ordering.

How do I identify Kohler GP876851 without removing it first?

Test handle motion (Rotate-only single handle (off -> cold -> warm -> hot)) and inspect under the sleeve for 2-screw polymer mounting ring over K-8304 brass body.

Where do the engineering metrics for Kohler GP876851 originate?

Data provenance for Kohler GP876851 links straight to verified agency releases and OEM installation bulletins. Confirmed fitment applies across Kohler K-8304-KS, K-8304-PX, K-8304-UX, K-P8304 rough-in bodies.

When should homeowners stop and call 911 or a pro on Kohler GP876851?

Online tables clarify baseline engineering limits, not site-specific hazards like live gas odors or corroded service mains. Shut off house or local isolation valves and release pressure before removing retaining clips or bonnet nuts.

Which federal regulatory baselines intersect with Kohler GP876851?

Check local Authority Having Jurisdiction amendments to IPC/UPC codes alongside federal EPA drinking water and 10 CFR 430 efficiency mandates.

Which incentives remain open in 2026 for plumbing equipment?

Verify active state DOE HEAR allocations (up to $1,750 for heat pump water heaters) and local utility rebates following the Dec 31, 2025 25C expiration.

When should a homeowner escalate Kohler GP876851 to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

Does TapAndPipe accept paid placements inside Kohler GP876851?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

Sources

  1. Kohler Rite-Temp Pressure-Balancing Valve & Toilet Flush Valve Specifications — Kohler Co., Kohler Service Parts Portal (retrieved 2026-11-23)
  2. ASTM B88 Copper Water Tube & ASME B1.20.1 Pipe Threads — ASTM International & ASME, ASTM B88 / F876 / ASME B1.20.1 (retrieved 2026-11-23)
  3. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  4. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks