Skip to main content
OEM part specification · Uponor

Uponor ProPEX ASTM F1960 Cold-Expansion PEX-a Ring & Fitting Spec

OEM specification for Uponor F1960 ProPEX Ring (Q4690500 / Q4690750): built for Cross-linked polyethylene (PEX-a) potable water distribution and radiant piping (Engel-method PEX-a (ASTM F876) over EP polymer or lead-free brass barbed fitting), identifiable by Cold mechanical expansion (minimum 3-5 sec contraction seal). Verify exact stem geometry (Must expand pipe+ring simultaneously with rotating expander head before insertion) and shut off hot and cold isolation stops before removing retaining clips.

OEM Part Number
F1960 ProPEX Ring (Q4690500 / Q4690750)
Operating / Join Action
Cold mechanical expansion
Retainer / Seal Style
Memory-polymer ProPEX expansion ring with integrated tube stop
Compatible Series
1 Platform
Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip
Disassembled brass shower mixing valve body, ceramic cartridge, O-rings, and retaining clip
How to tell this part apart

Mechanical checks for Uponor F1960 ProPEX Ring (Q4690500 / Q4690750): motion — Cold mechanical expansion (minimum 3-5 sec contraction seal); retainer — Memory-polymer ProPEX expansion ring with integrated tube stop. Stem cue: Must expand pipe+ring simultaneously with rotating expander head before insertion.

CRITICAL: Never use ASTM F1960 cold expansion on PEX-b (crimp-only) unless explicitly F1960-rated.

How Do You Identify the Uponor F1960 ProPEX Ring (Q4690500 / Q4690750) Retainer?

Verify handle motion (Cold mechanical expansion) and retaining hardware (Memory-polymer ProPEX expansion ring with integrated tube stop) under the trim plate before pulling the cartridge or shutting off supply stops.

Shower Valve Cartridge Retainer Identification Diagram Side-by-side schematic comparing top wire U-clip (Moen 1222/1225), threaded bonnet nut (Delta RP46074/RP19804), and 4-bolt plate (Kohler Rite-Temp). 1. Top Wire U-Clip Moen 1222 / 1225 Pull U-clip upward; oval grommets (1222) 2. Threaded Bonnet Nut Delta RP46074 / RP19804 Grey cap = Post-2007 | White = Pre-2006 3. 4-Bolt Pressure Plate Kohler K-304 / K-8304 2-pc GP800820+PBU or 1-pc GP876851
Mechanical retainer anatomy: verify retainer style and handle action (rotate-only vs. pull-turn) before shutting water off or ordering OEM cartridges.

What Valves Fit Uponor F1960 ProPEX Ring (Q4690500 / Q4690750)?

Review complete OEM fitment specifications, body construction, non-interchangeable warnings, and federal WaterSense flow ceilings (45,604 certified fixtures) for F1960 ProPEX Ring (Q4690500 / Q4690750) below.

Verified OEM technical attributes for Uponor F1960 ProPEX Ring (Q4690500 / Q4690750)
AttributeVerified Specification
Primary ApplicationCross-linked polyethylene (PEX-a) potable water distribution and radiant piping
Handle ActionCold mechanical expansion (minimum 3-5 sec contraction seal)
Retainer MechanismMemory-polymer ProPEX expansion ring with integrated tube stop
Body & Seal ConstructionEngel-method PEX-a (ASTM F876) over EP polymer or lead-free brass barbed fitting
Stem / Fitment NoteMust expand pipe+ring simultaneously with rotating expander head before insertion
Compatible Valve Platforms1/2 in., 3/4 in., 1 in. ASTM F876 PEX-a tubing ONLY
Non-Interchangeable WarningCRITICAL: Never use ASTM F1960 cold expansion on PEX-b (crimp-only) unless explicitly F1960-rated.
Federal Fixture Flow RulesFaucets ≤2.2 gpm @ 60 psi under 10 CFR 430.32(o); WaterSense ≤1.5 gpm across 45,604 certified fixtures

How Does F1960 ProPEX Ring (Q4690500 / Q4690750) Compare to Peer OEM Parts?

Cross-check 6 adjacent residential OEM shower cartridges, push-to-connect couplings, and RPZ backflow repair assemblies to avoid incompatible part orders.

Cross-reference matrix of indexed residential OEM cartridges, connectors, and backflow kits
Brand & Part #ApplicationHandle / Join ActionRetainer Mechanism
Moen 1222 Posi-Temp tub and shower pressure-balancing valves Rotate-only Vertical wire/U-clip inserted through top of brass valve body
Moen 1225 Single-handle kitchen, bath, and Chateau shower faucets Pull out for volume, turn left/right for temperature Top brass/wire retainer clip behind escutcheon sleeve
Moen 1255 Post-2009 single-handle kitchen and bath sink faucets Lift/tilt lever forward-back + swivel left-right Threaded plastic locking nut
Delta RP46074 Post-2007 Delta 13/14 Series MultiChoice shower valves Rotate-only single handle Large threaded chrome/brass bonnet nut over valve body
Delta RP19804 Pre-2007 Monitor 1300 and 1400 tub/shower valves Rotate-only single lever Threaded bonnet nut
Kohler GP800820 / GP500520 Kohler Rite-Temp K-304 and K-8304 shower valves Rotate-only single handle 4-bolt stainless plate

What Are the Key Questions and Answers?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Which rough-in valves fit Uponor F1960 ProPEX Ring (Q4690500 / Q4690750)?

Uponor F1960 ProPEX Ring (Q4690500 / Q4690750) fits 1/2 in., 3/4 in., 1 in. ASTM F876 PEX-a tubing ONLY. Cross-check Engel-method PEX-a (ASTM F876) over EP polymer or lead-free brass barbed fitting before ordering.

How do I identify Uponor F1960 ProPEX Ring (Q4690500 / Q4690750) without removing it first?

Test handle motion (Cold mechanical expansion (minimum 3-5 sec contraction seal)) and inspect under the sleeve for Memory-polymer ProPEX expansion ring with integrated tube stop.

Where do the engineering metrics for Uponor F1960 ProPEX Ring (Q4690500 / Q4690750) originate?

Data provenance for Uponor F1960 ProPEX Ring (Q4690500 / Q4690750) links straight to verified agency releases and OEM installation bulletins. Confirmed fitment applies across 1/2 in., 3/4 in., 1 in. ASTM F876 PEX-a tubing ONLY.

When should homeowners stop and call 911 or a pro on Uponor F1960 ProPEX Ring (Q4690500 / Q4690750)?

Online tables clarify baseline engineering limits, not site-specific hazards like live gas odors or corroded service mains. Shut off house or local isolation valves and release pressure before removing retaining clips or bonnet nuts.

Which federal regulatory baselines intersect with Uponor F1960 ProPEX Ring (Q4690500 / Q4690750)?

Check local Authority Having Jurisdiction amendments to IPC/UPC codes alongside federal EPA drinking water and 10 CFR 430 efficiency mandates.

Which incentives remain open in 2026 for plumbing equipment?

Verify active state DOE HEAR allocations (up to $1,750 for heat pump water heaters) and local utility rebates following the Dec 31, 2025 25C expiration.

When should a homeowner escalate Uponor F1960 ProPEX Ring (Q4690500 / Q4690750) to a state-licensed plumber?

Escalate whenever tasks involve fuel-gas piping, Category IV exhaust venting, 240V electrical circuits, main shutoff valves, or permitted sewer excavations.

Does TapAndPipe accept paid placements inside Uponor F1960 ProPEX Ring (Q4690500 / Q4690750)?

No. All specifications, state benchmarks, and contractor lists derive strictly from official public records and OEM manuals with zero paid ranking boosts.

Sources

  1. Zurn Backflow, Uponor PEX-a Expansion & SharkBite Push-to-Connect Insertion Specs — Zurn Elkay / Uponor / Reliance Worldwide Corp (SharkBite), 2026 OEM Installation Specifications (retrieved 2026-11-23)
  2. ASTM B88 Copper Water Tube & ASME B1.20.1 Pipe Threads — ASTM International & ASME, ASTM B88 / F876 / ASME B1.20.1 (retrieved 2026-11-23)
  3. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  4. EPA WaterSense Labeled Plumbing Products Registry — U.S. Environmental Protection Agency, 2026 Certified Product Database (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks