A. O. Smith ATHR-180M 1** Water Heater Specifications (0.95 UEF)
In the 464-unit Gas Tankless class, A. O. Smith ATHR-180M 1** (Natural Gas, Propane) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 2866539) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is American GT-240-NEH 1** (0.95 UEF).
- Uniform Energy Factor
- 0.95 UEF
- Cohort UEF Rank
- #159 of 464
- First Hour Rating
- On-Demand
- Storage Volume
- Tankless
- Fuel / Type
- Natural Gas, Propane / Gas Tankless
- DOE 2029 Rule Status
- Pass: +0.04 / +4.4%

A. O. Smith ATHR-180M 1** records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.
DOE 2029 compliance check: A. O. Smith ATHR-180M 1** sits +0.04 UEF (+4.4%) above 0.91 UEF; thermal recovery tests at 97% (-1.0 pts vs. 98.0% median).
Competing options beside A. O. Smith ATHR-180M 1** (0.95 UEF) are American GT-240-NEH 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity).
What Physical and Thermal Ratings Define A. O. Smith ATHR-180M 1**?
Positioning at #159 of 464 out of 464 Gas Tankless peers, A. O. Smith ATHR-180M 1** pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 2866539 |
| Model Number | ATHR-180M 1** | Draw pattern: High-Usage | ATHR-180M 1** |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 97% | -1.0 pts vs. 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-12-18 | Certified 2023-12-18 | Markets: United States, Canada |
Have Any A. O. Smith Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to A. O. Smith ATHR-180M 1**?
Homeowners cross-shopping A. O. Smith ATHR-180M 1** frequently review these five Gas Tankless models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American GT-240-NEH 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bosch T9800 SE 160 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bradford White RTG-K-160N1 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Elios EROD150N0000 | Gas Tankless | — | — | 0.95 (at parity) | — |
| American GT-240-PEH 1*1 | Gas Tankless | — | — | 0.95 (at parity) | — |
Who Is A. O. Smith ATHR-180M 1** Best For — and When Should You Pick American GT-240-NEH 1**?
Evaluate whether A. O. Smith ATHR-180M 1**'s Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Converting a 40K tank to A. O. Smith ATHR-180M 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect A. O. Smith ATHR-180M 1**'s heat exchanger.
- Condensing A. O. Smith ATHR-180M 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for A. O. Smith ATHR-180M 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does A. O. Smith ATHR-180M 1** (0.95 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith ATHR-180M 1** records 0.95 UEF (Pass: +0.04 / +4.4%), placing #159 of 464 out of 464 certified Gas Tankless configurations.
Does A. O. Smith ATHR-180M 1** fit inside a tight hallway closet or low-headroom utility room?
Designed as a compact gas tankless platform (wall-hung / compact envelope), A. O. Smith ATHR-180M 1** still needs code-compliant flue separation from windows and gas meters.
What power supply or fuel line specs govern A. O. Smith ATHR-180M 1**?
Installing A. O. Smith ATHR-180M 1** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.
What annual utility bill should homeowners budget for A. O. Smith ATHR-180M 1**?
Rated 0.95 UEF on Natural Gas, Propane, A. O. Smith ATHR-180M 1** carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.
What are the main drawbacks of A. O. Smith ATHR-180M 1** (0.95 UEF)?
Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh American GT-240-NEH 1** or hybrid alternatives.
What hot-water delivery rating governs A. O. Smith ATHR-180M 1**?
On-demand Gas Tankless sizing for A. O. Smith ATHR-180M 1** depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.
Where do homeowners screen A. O. Smith ATHR-180M 1** for recalls and tank age?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to A. O. Smith ATHR-180M 1** in the Gas Tankless class?
Closest peer in Gas Tankless is American GT-240-NEH 1** (0.95 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)