Skip to main content
ENERGY STAR water heater model · PD 4015943

A. O. Smith ATM-199X3-N 1** Water Heater Specifications (0.95 UEF)

With PD 4015943 certification, A. O. Smith ATM-199X3-N 1** (Gas Tankless, Natural Gas) achieves a certified 0.95 UEF rating, standing #159 of 464 across 464 peers with Pass: +0.04 / +4.4% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is American GT-240-NEH 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking A. O. Smith ATM-199X3-N 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91A. O. Smith ATM-199X3-N 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows A. O. Smith ATM-199X3-N 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places A. O. Smith ATM-199X3-N 1** at 0.95 UEF (#159 of 464; At 0.95 UEF median) in Gas Tankless.

With Natural Gas condensing combustion, A. O. Smith ATM-199X3-N 1** stands +0.04 UEF (+4.4%) above the 2029 0.91 UEF minimum; thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).

In the Gas Tankless tier, American GT-240-NEH 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity) bracket A. O. Smith ATM-199X3-N 1**.

What Physical and Thermal Ratings Define A. O. Smith ATM-199X3-N 1**?

Positioning at #159 of 464 out of 464 Gas Tankless peers, A. O. Smith ATM-199X3-N 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4015943
Model NumberATM-199X3-N 1**Draw pattern: High-UsageATM-199X3-N 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency96%-2.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-04-21Certified 2025-04-21Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any A. O. Smith Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under A. O. Smith; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

What Are 5 Direct Alternatives to A. O. Smith ATM-199X3-N 1**?

Homeowners cross-shopping A. O. Smith ATM-199X3-N 1** frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
Elios EROD150N0000 Gas Tankless — — 0.95 (at parity) —
American GT-240-PEH 1*1 Gas Tankless — — 0.95 (at parity) —

Which Home Setups Are NOT a Fit for A. O. Smith ATM-199X3-N 1**?

Comparing A. O. Smith ATM-199X3-N 1** against American GT-240-NEH 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Converting a 40K tank to A. O. Smith ATM-199X3-N 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect A. O. Smith ATM-199X3-N 1**'s heat exchanger.
  • Condensing A. O. Smith ATM-199X3-N 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — A. O. Smith ATM-199X3-N 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Sizing, Efficiency & Recall Answers for A. O. Smith ATM-199X3-N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith ATM-199X3-N 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; A. O. Smith ATM-199X3-N 1** logs 0.95 UEF (Pass: +0.04 / +4.4%) within the 464-unit Gas Tankless group.

What physical clearance dimensions apply when installing A. O. Smith ATM-199X3-N 1**?

Because A. O. Smith ATM-199X3-N 1** is a gas tankless unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits A. O. Smith ATM-199X3-N 1**?

A. O. Smith ATM-199X3-N 1** utilizes Natural Gas combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for A. O. Smith ATM-199X3-N 1**?

A. O. Smith ATM-199X3-N 1** operates on Natural Gas (0.95 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing A. O. Smith ATM-199X3-N 1**?

Northern homes with 40–45 °F winter groundwater see reduced simultaneous GPM output from A. O. Smith ATM-199X3-N 1**, while hard water >7.0 GPG demands annual vinegar flushing.

Is A. O. Smith ATM-199X3-N 1** sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, A. O. Smith ATM-199X3-N 1** heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does A. O. Smith have active CPSC SaferProducts notices affecting ATM-199X3-N 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches A. O. Smith ATM-199X3-N 1** (0.95 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for A. O. Smith ATM-199X3-N 1**. Closest peer in Gas Tankless is American GT-240-NEH 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks