Skip to main content
ENERGY STAR water heater model · PD 4670334

A. O. Smith GT15TM-140M-N 1** Water Heater Specifications (0.95 UEF)

In the 464-unit Gas Tankless class, A. O. Smith GT15TM-140M-N 1** (Natural Gas) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 4670334) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is American GT-240-NEH 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking A. O. Smith GT15TM-140M-N 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91A. O. Smith GT15TM-140M-N 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows A. O. Smith GT15TM-140M-N 1** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith GT15TM-140M-N 1** records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: A. O. Smith GT15TM-140M-N 1** sits +0.04 UEF (+4.4%) above 0.91 UEF; thermal recovery tests at 97% (-1.0 pts vs. 98.0% median).

Competing options beside A. O. Smith GT15TM-140M-N 1** (0.95 UEF) are American GT-240-NEH 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity).

How Complete Are the Certified Metrics for A. O. Smith GT15TM-140M-N 1**?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, A. O. Smith GT15TM-140M-N 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4670334
Model NumberGT15TM-140M-N 1**Draw pattern: High-UsageGT15TM-140M-N 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency97%-1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2026-07-15Certified 2026-07-15Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to GT15TM-140M-N 1**?

Ordered by minimal capacity and UEF spread relative to A. O. Smith GT15TM-140M-N 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
Elios EROD150N0000 Gas Tankless — — 0.95 (at parity) —
American GT-240-PEH 1*1 Gas Tankless — — 0.95 (at parity) —

Who Is A. O. Smith GT15TM-140M-N 1** Best For — and When Should You Pick American GT-240-NEH 1**?

Evaluate whether A. O. Smith GT15TM-140M-N 1**'s Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Converting a 40K tank to A. O. Smith GT15TM-140M-N 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect A. O. Smith GT15TM-140M-N 1**'s heat exchanger.
  • Condensing A. O. Smith GT15TM-140M-N 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — A. O. Smith GT15TM-140M-N 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Practical Specs & Code Questions for A. O. Smith GT15TM-140M-N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does A. O. Smith GT15TM-140M-N 1** (0.95 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, A. O. Smith GT15TM-140M-N 1** records 0.95 UEF (Pass: +0.04 / +4.4%), placing #159 of 464 out of 464 certified Gas Tankless configurations.

Does A. O. Smith GT15TM-140M-N 1** fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact gas tankless platform (wall-hung / compact envelope), A. O. Smith GT15TM-140M-N 1** still needs code-compliant flue separation from windows and gas meters.

What power supply or fuel line specs govern A. O. Smith GT15TM-140M-N 1**?

Installing A. O. Smith GT15TM-140M-N 1** on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for A. O. Smith GT15TM-140M-N 1**?

Rated 0.95 UEF on Natural Gas, A. O. Smith GT15TM-140M-N 1** carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.

What are the main drawbacks of A. O. Smith GT15TM-140M-N 1** (0.95 UEF)?

Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh American GT-240-NEH 1** or hybrid alternatives.

What hot-water delivery rating governs A. O. Smith GT15TM-140M-N 1**?

On-demand Gas Tankless sizing for A. O. Smith GT15TM-140M-N 1** depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

Where do homeowners screen A. O. Smith GT15TM-140M-N 1** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to A. O. Smith GT15TM-140M-N 1** in the Gas Tankless class?

Closest peer in Gas Tankless is American GT-240-NEH 1** (0.95 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks