Skip to main content
ENERGY STAR water heater model · PD 4015962

A. O. Smith GT15TM-180X3-N Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas Gas Tankless unit, A. O. Smith GT15TM-180X3-N achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 4015962), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is American GT-240-NEH 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking A. O. Smith GT15TM-180X3-N at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91A. O. Smith GT15TM-180X3-N: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows A. O. Smith GT15TM-180X3-N relative to the cohort median.
Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, A. O. Smith GT15TM-180X3-N logs 0.95 UEF and ranks #159 of 464.

A. O. Smith GT15TM-180X3-N delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas tankless mandate; thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).

Cross-shopping A. O. Smith GT15TM-180X3-N (0.95 UEF)? Check American GT-240-NEH 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity).

How Complete Are the Certified Metrics for A. O. Smith GT15TM-180X3-N?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, A. O. Smith GT15TM-180X3-N brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4015962
Model NumberGT15TM-180X3-NDraw pattern: High-UsageGT15TM-180X3-N
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency96%-2.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-04-21Certified 2025-04-21Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are A. O. Smith Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for A. O. Smith and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which 5 Models Offer Similar Output to GT15TM-180X3-N?

Ordered by minimal capacity and UEF spread relative to A. O. Smith GT15TM-180X3-N, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
Elios EROD150N0000 Gas Tankless — — 0.95 (at parity) —
American GT-240-PEH 1*1 Gas Tankless — — 0.95 (at parity) —

What Installation Caveats Apply Before Buying A. O. Smith GT15TM-180X3-N?

Even high-UEF units like A. O. Smith GT15TM-180X3-N (0.95 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Converting a 40K tank to A. O. Smith GT15TM-180X3-N often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect A. O. Smith GT15TM-180X3-N's heat exchanger.
  • Condensing A. O. Smith GT15TM-180X3-N requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — A. O. Smith GT15TM-180X3-N delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Practical Specs & Code Questions for A. O. Smith GT15TM-180X3-N

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is A. O. Smith GT15TM-180X3-N eligible for continued manufacture past May 6, 2029?

At 0.95 UEF, A. O. Smith GT15TM-180X3-N achieves Pass: +0.04 / +4.4% for the 2029 DOE standard and stands #159 of 464 against American GT-240-NEH 1** and Bosch T9800 SE 160.

How tall and wide is A. O. Smith GT15TM-180X3-N, and what service clearance is needed?

A. O. Smith GT15TM-180X3-N saves floor space via its gas tankless layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

Will A. O. Smith GT15TM-180X3-N require upgrading household electrical panels or gas piping?

Check Natural Gas piping and venting for A. O. Smith GT15TM-180X3-N (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is A. O. Smith GT15TM-180X3-N economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for A. O. Smith GT15TM-180X3-N (Natural Gas, 0.95 UEF) hinge on household gallon demand and local gas utility tariffs compared with American GT-240-NEH 1**.

Which installation bottlenecks limit A. O. Smith GT15TM-180X3-N?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, A. O. Smith GT15TM-180X3-N requires added mechanical rework over standard tank replacements.

How does A. O. Smith GT15TM-180X3-N handle simultaneous showers and laundry?

A. O. Smith GT15TM-180X3-N supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

How long is the warranty on A. O. Smith GT15TM-180X3-N and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying A. O. Smith GT15TM-180X3-N?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is American GT-240-NEH 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks