A. O. Smith GT15TM-199M-P 1*1 Water Heater Specifications (0.95 UEF)
In the 464-unit Gas Tankless class, A. O. Smith GT15TM-199M-P 1*1 (Propane) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 4617119) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is American GT-240-NEH 1** (0.95 UEF).
- Uniform Energy Factor
- 0.95 UEF
- Cohort UEF Rank
- #159 of 464
- First Hour Rating
- On-Demand
- Storage Volume
- Tankless
- Fuel / Type
- Propane / Gas Tankless
- DOE 2029 Rule Status
- Pass: +0.04 / +4.4%

A. O. Smith GT15TM-199M-P 1*1 records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.
DOE 2029 compliance check: A. O. Smith GT15TM-199M-P 1*1 sits +0.04 UEF (+4.4%) above 0.91 UEF; thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).
Competing options beside A. O. Smith GT15TM-199M-P 1*1 (0.95 UEF) are American GT-240-NEH 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity).
Which Specs Set A. O. Smith GT15TM-199M-P 1*1 Apart From Cohort Averages?
Ranked #159 of 464 inside the 464-model Gas Tankless cohort, A. O. Smith GT15TM-199M-P 1*1 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 4617119 |
| Model Number | GT15TM-199M-P 1*1 | Draw pattern: High-Usage | GT15TM-199M-P 1*1 |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 96% | -2.0 pts vs. 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2026-05-27 | Certified 2026-05-27 | Markets: United States |
What Should A. O. Smith Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your GT15TM-199M-P 1*1 production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Gas Tankless Models Stack Up?
Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American GT-240-NEH 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bosch T9800 SE 160 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bradford White RTG-K-160N1 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Elios EROD150N0000 | Gas Tankless | — | — | 0.95 (at parity) | — |
| American GT-240-PEH 1*1 | Gas Tankless | — | — | 0.95 (at parity) | — |
When Should Homeowners Skip A. O. Smith GT15TM-199M-P 1*1 (Gas Tankless)?
Check A. O. Smith GT15TM-199M-P 1*1's mechanical constraints—including utility space, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.
Key Limitations & Exclusions
- Converting a 40K tank to A. O. Smith GT15TM-199M-P 1*1 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect A. O. Smith GT15TM-199M-P 1*1's heat exchanger.
- Condensing A. O. Smith GT15TM-199M-P 1*1 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: A. O. Smith GT15TM-199M-P 1*1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will A. O. Smith GT15TM-199M-P 1*1 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 0.95 UEF, A. O. Smith GT15TM-199M-P 1*1 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like American GT-240-NEH 1**.
Will A. O. Smith GT15TM-199M-P 1*1 fit through a standard utility door and 72-inch basement ceiling?
Using a wall-mounted gas tankless chassis, A. O. Smith GT15TM-199M-P 1*1 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.
Do existing utility hookups support A. O. Smith GT15TM-199M-P 1*1 during replacement?
Fueled by Propane, A. O. Smith GT15TM-199M-P 1*1 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.
What is the estimated 10-year operating spend for A. O. Smith GT15TM-199M-P 1*1?
Because A. O. Smith GT15TM-199M-P 1*1 burns Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.
When is A. O. Smith GT15TM-199M-P 1*1 a poor fit for a residential replacement?
Skip A. O. Smith GT15TM-199M-P 1*1 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.
What First Hour Rating or flow capacity does A. O. Smith GT15TM-199M-P 1*1 deliver?
As an on-demand Gas Tankless model, A. O. Smith GT15TM-199M-P 1*1 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.
How do you verify manufacturing age and recall status on A. O. Smith GT15TM-199M-P 1*1?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
Does A. O. Smith GT15TM-199M-P 1*1 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith GT15TM-199M-P 1*1. Closest peer in Gas Tankless is American GT-240-NEH 1** (0.95 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)