A. O. Smith HPACO-45 1**+AXST-66 1** Water Heater Specifications (3.7 UEF)
Certified at 3.7 UEF across its 60-gallon nominal tank, 82 gal First Hour Rating, A. O. Smith HPACO-45 1**+AXST-66 1** (Hybrid/Electric Heat Pump, Electric) places #347 of 706 out of 706 ENERGY STAR models (PD 4529471). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.20 / +48.0%. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American MHPCO-45 1**+MXST-66 1** (3.7 UEF).
- Uniform Energy Factor
- 3.7 UEF
- Cohort UEF Rank
- #347 of 706
- First Hour Rating
- 82 gal
- Storage Volume
- 60 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.20 / +48.0%

Tested at 3.7 UEF, A. O. Smith HPACO-45 1**+AXST-66 1** places #347 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (At 3.70 UEF median).
A. O. Smith HPACO-45 1**+AXST-66 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.20 UEF (+48.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for A. O. Smith HPACO-45 1**+AXST-66 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for A. O. Smith HPACO-45 1**+AXST-66 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to A. O. Smith HPACO-45 1**+AXST-66 1** include American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity) alongside Giant GTHPCO-45 1**+GTXST-66 1** (3.7 UEF, at parity).
Which Specs Set A. O. Smith HPACO-45 1**+AXST-66 1** Apart From Cohort Averages?
Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPACO-45 1**+AXST-66 1** is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | A. O. Smith | 144 certified listings | ENERGY STAR PD 4529471 |
| Model Number | HPACO-45 1**+AXST-66 1** | Draw pattern: High-Usage | HPACO-45 1**+AXST-66 1** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,341 kWh/yr | +269 kWh/yr vs. 1,072 kWh/yr median | Est. $244/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 | Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States, Canada |
How Do Regional kWh Prices Impact HPACO-45 1**+AXST-66 1** Over 10 Years?
Using EIA Table 5.6.A benchmarks, A. O. Smith HPACO-45 1**+AXST-66 1**'s 1,341 kWh/yr draw translates to roughly $244/yr on typical US residential bills.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $244/yr | $2,435 | $7,358 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $633/yr | $6,327 | $19,117 |
| California | 29.75 ¢/kWh ($0.2975) | $399/yr | $3,989 | $12,055 |
| Texas | 15.91 ¢/kWh ($0.1591) | $213/yr | $2,134 | $6,447 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $196/yr | $1,962 | $5,928 |
What Should A. O. Smith Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPACO-45 1**+AXST-66 1** production run falls inside affected ranges. See Serial Number Lookup.
- Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
- Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?
Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| American MHPCO-45 1**+MXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| Giant GTHPCO-45 1**+GTXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| GSW WATER HEATERS GHPCO-45 1**+GXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| John Wood JWHPCO-45 1**+JWXST-66 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| American MHPCO-45 1**+MXST-66TTP 1** | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
What Are the Limitations of A. O. Smith HPACO-45 1**+AXST-66 1** and Who Should Not Install It?
Before ordering A. O. Smith HPACO-45 1**+AXST-66 1** (Hybrid/Electric Heat Pump, 3.7 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- A. O. Smith HPACO-45 1**+AXST-66 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting A. O. Smith HPACO-45 1**+AXST-66 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: A. O. Smith HPACO-45 1**+AXST-66 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does A. O. Smith HPACO-45 1**+AXST-66 1** pass the May 6, 2029 federal DOE efficiency rule?
A. O. Smith HPACO-45 1**+AXST-66 1** carries a verified 3.7 UEF rating (Pass: +1.20 / +48.0%), ranking #347 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.
What doorway width and ceiling height does A. O. Smith HPACO-45 1**+AXST-66 1** need?
A. O. Smith HPACO-45 1**+AXST-66 1** stands 59 in. high with a 18 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.
What gas pipe size or electrical breaker does A. O. Smith HPACO-45 1**+AXST-66 1** require?
A. O. Smith HPACO-45 1**+AXST-66 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.
How much electricity or energy does A. O. Smith HPACO-45 1**+AXST-66 1** cost per year to run?
Rated at 1,341 kWh/yr, A. O. Smith HPACO-45 1**+AXST-66 1** costs about $244/yr ($2,440 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii).
Who should NOT install A. O. Smith HPACO-45 1**+AXST-66 1**, and what are its limits?
A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.
How many bathrooms or people can A. O. Smith HPACO-45 1**+AXST-66 1** serve at peak demand?
A. O. Smith HPACO-45 1**+AXST-66 1** achieves a 82 gal First Hour Rating (+10 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.
Are there CPSC safety recalls or serial checks for A. O. Smith HPACO-45 1**+AXST-66 1**?
CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to A. O. Smith HPACO-45 1**+AXST-66 1**, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is American MHPCO-45 1**+MXST-66 1** (3.7 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)