A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** Water Heater Specifications (3.7 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** (Electric) achieves a certified 3.7 UEF rating across its 60-gallon nominal tank, 82 gal First Hour Rating (rank #347 of 706, PD 4529409) and verifies as Pass: +1.20 / +48.0% for 2029 DOE floors. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is American MHPCO-45 1**+MXST-66 1** (3.7 UEF).

Uniform Energy Factor
3.7 UEF
Cohort UEF Rank
#347 of 706
First Hour Rating
82 gal
Storage Volume
60 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.20 / +48.0%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** at 3.7 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.50A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**: 3.70
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** relative to the cohort median.
Efficiency comparison & rule summary

A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** records 3.7 UEF efficiency, putting it #347 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.20 UEF (+48.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** (3.7 UEF) are American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity) and Giant GTHPCO-45 1**+GTXST-66 1** (3.7 UEF, at parity).

Which Specs Set A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** Apart From Cohort Averages?

Ranked #347 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandA. O. Smith144 certified listingsENERGY STAR PD 4529409
Model NumberHPACO-45C 1**+AXST-66CTTP 1**Draw pattern: High-UsageHPACO-45C 1**+AXST-66CTTP 1**
Uniform Energy Factor (UEF)3.7At 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)82 gal+10 gal vs. 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use1,341 kWh/yr+269 kWh/yr vs. 1,072 kWh/yr medianEst. $244/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency435%+6.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)59" H x 18" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-19Certified 2026-03-19Markets: United States, Canada

How Do Regional kWh Prices Impact HPACO-45C 1**+AXST-66CTTP 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**'s 1,341 kWh/yr draw translates to roughly $244/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (1,341 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$244.00/yrHawaii$633.00/yrCalifornia$399.00/yrTexas$213.00/yrWashington$196.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $244/yr $2,435 $7,358
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $633/yr $6,327 $19,117
California 29.75 ¢/kWh ($0.2975) $399/yr $3,989 $12,055
Texas 15.91 ¢/kWh ($0.1591) $213/yr $2,134 $6,447
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $196/yr $1,962 $5,928
Estimated electricity spend (1,341 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should A. O. Smith Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to A. O. Smith; verify whether your HPACO-45C 1**+AXST-66CTTP 1** production run falls inside affected ranges. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19030 (2018-11-08): A. O. Smith Recalls 30-Gallon Gas Water Heaters Due to Fire Hazard; Sold Exclusively at Lowe's (CPSC Notice)
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
American MHPCO-45 1**+MXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
Giant GTHPCO-45 1**+GTXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
GSW WATER HEATERS GHPCO-45 1**+GXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
John Wood JWHPCO-45 1**+JWXST-66 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341
American MHPCO-45 1**+MXST-66TTP 1** Hybrid/Electric Heat Pump 60 gal 82 gal 3.7 (at parity) 1,341

When Should Homeowners Skip A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** (Hybrid/Electric Heat Pump)?

Check A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +1.20 / +48.0% status—against typical residential installations.

Key Limitations & Exclusions

  • A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare American MHPCO-45 1**+MXST-66 1** footprint.

Frequently Asked Technical Questions: A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.7 UEF, A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** shows Pass: +1.20 / +48.0% relative to May 6, 2029 federal DOE limits while placing #347 of 706 among 706 Hybrid/Electric Heat Pump peers like American MHPCO-45 1**+MXST-66 1**.

Will A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 59 in. tall by 18 in. diameter, A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** during replacement?

Electrical specs for A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** call for 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

What is the estimated 10-year operating spend for A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**?

At 18.16 cents/kWh national residential pricing, A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**'s 1,341 kWh/yr draw equals roughly $244 annually or $2,440 across a 10-year horizon (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii).

When is A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** a poor fit for a residential replacement?

Avoid placing A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

What First Hour Rating or flow capacity does A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** deliver?

With 82 gal FHR (+10 gal vs. 72 gal median), A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning A. O. Smith as of 2026-11-23, including #19030 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does A. O. Smith HPACO-45C 1**+AXST-66CTTP 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for A. O. Smith HPACO-45C 1**+AXST-66CTTP 1**. Closest peer in Hybrid/Electric Heat Pump is American MHPCO-45 1**+MXST-66 1** (3.7 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks