Skip to main content
ENERGY STAR water heater model · PD 2407897

AET B-DBS-G2-80-64 Water Heater Specifications (1.9 SUEF)

Engineered as a Natural Gas Solar with Gas Backup unit, AET B-DBS-G2-80-64 achieves a certified 1.9 SUEF rating across its 80-gallon nominal tank and ranks #25 of 25 in its 25-model cohort (PD 2407897), recording Exempt — Solar SUEF under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF).

Solar UEF (SUEF)
1.9 SUEF
Cohort SUEF Rank
#25 of 25
First Hour Rating
On-Demand
Storage Volume
80 gal
Fuel / Type
Natural Gas / Solar with Gas Backup
DOE 2029 Rule Status
Exempt — Solar SUEF
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units)Distribution of certified SUEF ratings across 25 units in Solar with Gas Backup, marking AET B-DBS-G2-80-64 at 1.9 SUEF.9112121.90 SUEF99.00 SUEFMedian 84.50AET B-DBS-G2-80-64: 1.90
Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows AET B-DBS-G2-80-64 relative to the cohort median.
Efficiency comparison & rule summary

Within the 25-unit Solar with Gas Backup cohort, AET B-DBS-G2-80-64 logs 1.9 SUEF and ranks #25 of 25.

Solar collector & storage profile, OG-300 #2010017C for AET B-DBS-G2-80-64: Indirect Forced Circulation architecture; 65.3 sq ft Flat Plate collector; 80 gal storage tank; freeze limit -58 deg F.

Cross-shopping AET B-DBS-G2-80-64 (1.9 SUEF)? Check Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF, delta +97.10) and Rheem RS80-40BP-TG (8.0 SUEF, delta +6.10).

How Complete Are the Certified Metrics for AET B-DBS-G2-80-64?

Standing at #25 of 25 among 25 certified Solar with Gas Backup heaters, AET B-DBS-G2-80-64 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAET7 certified listingsENERGY STAR PD 2407897
Model NumberB-DBS-G2-80-64Draw pattern: High-UsageB-DBS-G2-80-64
Solar Uniform Energy Factor (SUEF)1.9-82.60 SUEF vs. 84.50 SUEF median10 CFR 430 Test Method
Solar System & CollectorIndirect Forced Circulation (Flat Plate)65.3 sq ft apertureOG-300 #2010017C
Collector Freeze Tolerance-58 °FSRCC freeze protection ratingENERGY STAR Solar Dataset
Certification Date2019-11-12Certified 2019-11-12Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are AET Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched AET in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to B-DBS-G2-80-64?

Ordered by minimal capacity and SUEF spread relative to AET B-DBS-G2-80-64, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRSUEF (Δ)kWh/yr
Heliodyne HPAK 1 408 GT 80 ACD Z Solar with Gas Backup 80 gal — 99.0 (+97.10) —
Rheem RS80-40BP-TG Solar with Gas Backup 80 gal — 8.0 (+6.10) —
Solahart ASTG 302J Solar with Gas Backup 80 gal — 84.5 (+82.60) —
SAMMLER A308 Solar with Gas Backup 79 gal — 99.0 (+97.10) —
Heliodyne HPAK 1 410 GT 120 ACD Z Solar with Gas Backup 80 gal — 99.0 (+97.10) —

When Should Homeowners Skip AET B-DBS-G2-80-64 (Solar with Gas Backup)?

Check AET B-DBS-G2-80-64's mechanical constraints—including utility space, Natural Gas capacity, and Exempt — Solar SUEF status—against typical residential installations.

Key Limitations & Exclusions

  • AET B-DBS-G2-80-64 logs 1.9 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect AET B-DBS-G2-80-64's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 80 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for AET B-DBS-G2-80-64 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Heliodyne HPAK 1 408 GT 80 ACD Z.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Practical Specs & Code Questions for AET B-DBS-G2-80-64

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will AET B-DBS-G2-80-64 stay compliant after the May 6, 2029 DOE standard takes effect?

Rated at 1.9 SUEF, AET B-DBS-G2-80-64 uses SRCC solar collector physics exempt from the May 6, 2029 tank UEF rules, keeping it compliant alongside Heliodyne HPAK 1 408 GT 80 ACD Z.

Will AET B-DBS-G2-80-64 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted solar with gas backup chassis, AET B-DBS-G2-80-64 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support AET B-DBS-G2-80-64 during replacement?

Fueled by Natural Gas, AET B-DBS-G2-80-64 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for AET B-DBS-G2-80-64?

Because AET B-DBS-G2-80-64 burns Natural Gas at 1.9 SUEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 25 peers.

When is AET B-DBS-G2-80-64 a poor fit for a residential replacement?

Avoid AET B-DBS-G2-80-64 if household peak demand surpasses 80 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

What First Hour Rating or flow capacity does AET B-DBS-G2-80-64 deliver?

As an on-demand Solar with Gas Backup model, AET B-DBS-G2-80-64 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on AET B-DBS-G2-80-64?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for AET; verify exact manufacturing week for AET B-DBS-G2-80-64 using the Serial Number Lookup tool.

Does AET B-DBS-G2-80-64 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for AET B-DBS-G2-80-64. Closest peer in Solar with Gas Backup is Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks