American GT-540P-PEH 1*1 Water Heater Specifications (0.95 UEF)
With PD 2408663 certification, American GT-540P-PEH 1*1 (Gas Tankless, Propane) achieves a certified 0.95 UEF rating, standing #159 of 464 across 464 peers with Pass: +0.04 / +4.4% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).
- Uniform Energy Factor
- 0.95 UEF
- Cohort UEF Rank
- #159 of 464
- First Hour Rating
- On-Demand
- Storage Volume
- Tankless
- Fuel / Type
- Propane / Gas Tankless
- DOE 2029 Rule Status
- Pass: +0.04 / +4.4%

ENERGY STAR certification places American GT-540P-PEH 1*1 at 0.95 UEF (#159 of 464; At 0.95 UEF median) in Gas Tankless.
With Propane condensing combustion, American GT-540P-PEH 1*1 stands +0.04 UEF (+4.4%) above the 2029 0.91 UEF minimum.
In the Gas Tankless tier, A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and Bosch T9800 SE 160 (0.95 UEF, at parity) bracket American GT-540P-PEH 1*1.
What Physical and Thermal Ratings Define American GT-540P-PEH 1*1?
Positioning at #159 of 464 out of 464 Gas Tankless peers, American GT-540P-PEH 1*1 pairs measured UEF performance with specific clearance and wiring rules.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 2408663 |
| Model Number | GT-540P-PEH 1*1 | Draw pattern: High-Usage | GT-540P-PEH 1*1 |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |
Have Any American Series Triggered CPSC Recalls?
SaferProducts records retrieved 2026-11-23 list 2 brand notices under American; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
What Are 5 Direct Alternatives to American GT-540P-PEH 1*1?
Homeowners cross-shopping American GT-540P-PEH 1*1 frequently review these five Gas Tankless models ranked closest on capacity and UEF output.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith ACT-199O-N 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bosch T9800 SE 160 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bradford White RTG-K-160N1 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Elios EROD150N0000 | Gas Tankless | — | — | 0.95 (at parity) | — |
| A. O. Smith ACT-199O-P 1*1 | Gas Tankless | — | — | 0.95 (at parity) | — |
Who Is American GT-540P-PEH 1*1 Best For — and When Should You Pick A. O. Smith ACT-199O-N 1**?
Evaluate whether American GT-540P-PEH 1*1's Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Converting a 40K tank to American GT-540P-PEH 1*1 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect American GT-540P-PEH 1*1's heat exchanger.
- Condensing American GT-540P-PEH 1*1 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.
Which Option Fits Your Situation?
Sizing, Efficiency & Recall Answers for American GT-540P-PEH 1*1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does American GT-540P-PEH 1*1 (0.95 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American GT-540P-PEH 1*1 records 0.95 UEF (Pass: +0.04 / +4.4%), placing #159 of 464 out of 464 certified Gas Tankless configurations.
Does American GT-540P-PEH 1*1 fit inside a tight hallway closet or low-headroom utility room?
Designed as a compact gas tankless platform (wall-hung / compact envelope), American GT-540P-PEH 1*1 still needs code-compliant flue separation from windows and gas meters.
What power supply or fuel line specs govern American GT-540P-PEH 1*1?
Installing American GT-540P-PEH 1*1 on Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.
What annual utility bill should homeowners budget for American GT-540P-PEH 1*1?
Rated 0.95 UEF on Propane, American GT-540P-PEH 1*1 carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.
What are the main drawbacks of American GT-540P-PEH 1*1 (0.95 UEF)?
Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh A. O. Smith ACT-199O-N 1** or hybrid alternatives.
What hot-water delivery rating governs American GT-540P-PEH 1*1?
On-demand Gas Tankless sizing for American GT-540P-PEH 1*1 depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.
Where do homeowners screen American GT-540P-PEH 1*1 for recalls and tank age?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to American GT-540P-PEH 1*1 in the Gas Tankless class?
Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)